background image

 

 

Programming 

 
The DAB ACTIVE DRIVER is easy to program, it is essential that key information about the 
DUTY POINT and PUMP are know before attempting to program the unit. 
 

>ESSENTIAL INFORMATION 

 

1.

 

DUTY POINT (Pressure) 

2.

 

Rated Current of Pump (not required for AD M/M 1.1) 

3.

 

Pump Curve 

 
>>Duty Point is the required pressure the system is required to run at. This is inputted in 
(Bar). 
 
>>The rated current of the pump can be located on the compliance plate attached to the 
pump, or is listed in the DAB Factory catalogue in the ELECTRICAL DATA table. 
 
This is only relevant when using three phase pumps. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
>>The Pump Curve is essential to ensure that the duty point is achievable with the pump 
selected. 
 
The settings should be recorded in the ACTIVE DRIVER manual for later reference. 
 
It is essential to READ THE MANUAL before attempting to operate the ACTIVE DRIVER. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание ACTIVE DRIVER M/M 1.1

Страница 1: ...configurations ACTIVE DRIVER M M 1 1 Suits single phase 230v power supply and will couple to single phase pump units up to 1 1kW and is programmable to a maximum pressure of 6 Bar 600kPa not exceed a...

Страница 2: ...ting a set point of 350kPa will mean that the pump will normally run at lower frequency speed and less likely to cavitate Installing the ACTIVE DRIVER The ACTIVE DRIVER would normally be installed in...

Страница 3: ...stem is required to run at This is inputted in Bar The rated current of the pump can be located on the compliance plate attached to the pump or is listed in the DAB Factory catalogue in the ELECTRICAL...

Страница 4: ...the back of this guide Displays of the Main Values It is also possible to access operational information of the system by pressing the mode key these indications are Fr Displays the current frequency...

Страница 5: ...e desired operating pressure of the system To access this setting press mode and set simultaneously for two seconds the display should indicate SP and then flash to 3 0 which is the pre set of 3 0 Bar...

Страница 6: ...e system Go or Sb od OPERATING MODE this refers to the presence of a pressure cell To access this setting press mode set and simultaneously for five seconds press mode until the display indicates od a...

Страница 7: ...or Sb Eb ENABLING THE BOOSTER turn the alternating function on in a multiple pumps system Not applicable to the AD M M 1 1 To access this setting press mode set and simultaneously for five seconds pre...

Страница 8: ...8 Programming Resetting Factory Settings It is possible to restore the default settings by pressing set an for two seconds whilst restoring the power supply switching on...

Страница 9: ...9 Programming Quick Set Up The following is a quick set up procedure for basic operation for all settable parameters refer to the complete input list on the last page...

Страница 10: ...10...

Отзывы: