![DAB PUMPS PWM 201 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/dab-pumps/pwm-201/pwm-201_instruction-for-installation-and-maintenance_495533076.webp)
ENGLISH
74
The rated voltage of the electric pump must be the same as the supply voltage of the inverter.
The rated frequency of the electric pump can be set via the display according to the specifications on the manufacturer’s dataplate.
For example, the inverter can also be powered at 50 [Hz] with control of an electric pump at 60 [Hz] - nominal (provided that the
pump is declared as compatible for this frequency).
For special applications, pumps are also available with frequency up to 200 [Hz].
The utility connected to the inverter must not absorb current in excess of the maximum values specified in Table 1.
Check the dataplates and type of motor connection (star or delta) used to ensure compliance with the above conditions.
2.2.1.4
Electrical connections to the electric pump PWM 203 – 202 – 201
Models PWM 203 – 202 – 201 require motor configuration for a three-phase voltage of 230V. This is normally obtained by a delta
configuration of the motor. See Figure 5.
Figure 5: Pump connection PWM 203 - 202 – 201
Incorrect connection of the earthing line, to a terminal other than the earth terminal can cause irremediable
damage to the equipment.
Incorrect connection of the power line on the output load terminals can cause irremediable damage to the
equipment.
Current absorption and thermal magnetic circuit breaker sizing for maximum power
PWM 203
PWM 202
PWM 201
Supply voltage [V]
230 V
230 V
230 V
Max. motor current absorption [A]
11,0
9,0
6,5
Max. inverter current absorption [A]
25,0
18,7
12,0
Rated current of thermal magnetic circuit breaker [A]
32
20
16
PWM 407
PWM 405
PWM 404
Supply voltage [ 3 x V]
380
480
380
480
380
480
Max. motor current absorption [A]
15,0
11,5
11,0
8,7
9,0
7,2
Max. inverter current absorption [A
20,5
16,5
16
12,0
12,5
10,0
Rated current of thermal magnetic circuit breaker [A]
25
20
20
16
16
16
PWM 420
PWM 415
PWM 410
Supply voltage [ 3 x V]
380
480
380
480
380
480
Max. motor current absorption [A]
41,0
32,5
31,0
24,5
22,0
17,5
Max. inverter current absorption [A
55,0
44,0
42,0
33,0
29,5
23,5
Rated current of thermal magnetic circuit breaker [A]
63
50
50
40
32
25
Table 3: Current absorption and thermal magnetic circuit breaker sizing for maximum power
Содержание PWM 201
Страница 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Страница 73: ...ENGLISH 71 Figure 2 Fixture and minimum clearance for air circulation...
Страница 129: ...FRAN AIS 127 Figure 2 Fixation et distance minimum pour la circulation de l air...
Страница 185: ...DEUTSCH 183 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Страница 244: ...ESPA OL 242 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Страница 295: ...293 IEC 60634...
Страница 296: ...294 1 6 1 1...
Страница 300: ...298 1 2 5 2 1 2 1 2 2...
Страница 301: ...299 2...
Страница 302: ...300 2 2 3 3 15 2 2 1 4 2 2 1 1 PWM 203 202 201 3 1 LN 4 2 3...
Страница 306: ...304 6 2 2 3 3 Press e Flow 7 A B C D...
Страница 308: ...306 8 4 20 5 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 o OUT 7 J5 4 20 7 OUT 8 10 11 IN...
Страница 311: ...309 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 7 11 8 11...
Страница 313: ...311 9 MODE 1 SET 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET MODE 10...
Страница 315: ...313 SO AE MP I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 RF PW 11 3 2 2 13 SET 13 15 14...
Страница 316: ...314 14 3 3 12 GO SB BL LP HP EC OC OF SC OT...
Страница 317: ...315 12 15 13 15 3 4 PW 6 6 16 OB BP NC F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E0 E16 0 16 EE EEprom WARN GO SB...
Страница 318: ...316 4 4 1 Link 8 4 2 4 2 1 Link Link 16...
Страница 319: ...317 16 Link 4 2 2 0 5V 4 20 A 0 4 2 2 1 FI FI 4 2 2 2 FZ 6 5 9 1 4 2 2 3 0 5 4 20 A 0 5 0 5 4 20 A 2 2 3 1...
Страница 322: ...320 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL 4 5 1 4 5 1 1 ET ET ET ET 0 ET 6 6 9 4 5 1 2 23 23...
Страница 327: ...325 15 SB F 15 SM 15 F Sb RC A SM 6 1 6 VE 6 2 2 SET MODE 6 2 1 VF 6 2 2 TE 6 2 3 BT 6 2 4 FF FF x y x y x 1 x y 64 RF...
Страница 344: ...342 FF 6 6 16 PW PW 0 PW 0 PW XXXX 10 PW 2 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...
Страница 359: ...NEDERLANDS 357 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Страница 418: ...SVENSKA 416 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Страница 473: ...T RK E 471 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Страница 523: ...520 IEC 364 inverter...
Страница 524: ...521 1 Inverter inverter inverter 6 inverter 1 1...
Страница 528: ...525 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Страница 529: ...526 2...
Страница 530: ...527 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 4 2 2 1 1 PWM 203 202 201 inverter 3 1 LN 4 inverter 2...
Страница 534: ...531 6 2 2 3 3 Press Flow 7 A B C D...
Страница 539: ...536 DC V AC 50 60 Hz Vrms V 8 6 V 2 1 5 V 36 36 12V mA 3 3 3 3 mm 2 13 7 11 8...
Страница 540: ...537 11 J5 pin Pin I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 8...
Страница 542: ...539 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5...
Страница 545: ...542 14 3 3 go Hz bar psi 12 GO SB BL LP HP EC OC OF SC OT...
Страница 588: ...ROM N 585 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Страница 635: ...01 20 cod 60198807...