INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
41
Instruction manual edition 1 for EP104 version 4.08
Automatic closing
No.
Name
Range
Factory Setting Ref.
page
C500
Automatic closing time
0.00-9.59 minutes
0.00
C501
Short automatic closing time
0.0-9.9 seconds
0.0
C510
Time for LOOP1, LOOP2 and PHOTO closing
during passage
00-99 seconds
00
C520
Blocking time for automatic closing after the stop
button is pressed
0.00 and 0.20-9.59
minutes
0.00
C591
Direction sensing for internal closing pulse
00 - 14
00
00
Disabled
01
Presence detection, LOOP1 must first be activated, signal when LOOP1 is disabled.
02
Presence detection, LOOP2 must first be activated, signal when LOOP2 is disabled.
03
Presence detection, LOOP1 or LOOP2 must first be activated, signal when either LOOP1 or LOOP2
is activated.
04
Presence detection, PHOTO must first be activated, signal when PHOTO is disabled.
05
Presence detection, PHOTO and LOOP1 must first be activated simultaneously, signal when either
PHOTO or LOOP1 is clear.
06
Presence detection, PHOTO and LOOP2 must first be activated simultaneously, signal when either
PHOTO or LOOP2 is clear.
07
Presence detection, PHOTO LOOP1 and LOOP2 must first be activated simultaneously, signal when
either PHOTO, LOOP1 or LOOP2 is clear.
08
Presence detection, LOOP1 and LOOP2 must first be activated simultaneously, signal when either
LOOP1 or LOOP2 is clear.
09
Direction sensing, LOOP1 must first be activated, during the time LOOP2 must be activated, then
LOOP1 must be disabled, signal when LOOP2 is disabled.
10
Direction sensing, LOOP1 must first be activated, during the time PHOTO must be activated, then
LOOP1 must be disabled, signal when PHOTO is disabled.
11
Direction sensing, LOOP2 must first be activated, during the time LOOP1 must be activated, then
LOOP2 must be disabled, signal when LOOP1 is disabled.
12
Direction sensing, LOOP2 must first be activated, during the time PHOTO must be activated, then
LOOP2 must be disabled, signal when PHOTO is disabled.
13
Direction sensing, PHOTO must first be activated, during the time LOOP1 must be activated, then
PHOTO must be disabled, signal when LOOP1 is disabled.
14
Direction sensing, PHOTO must first be activated, during the time LOOP2 must be activated, then
PHOTO must be disabled, signal when LOOP2 is disabled.
Содержание EP104
Страница 60: ......