Load guard and motor settings
No.
Name
Range
Factory Setting Ref.
page
S
C200 Load guard function
0 – 4
3
0
Disabled Service and troubleshooting only
1
Reverse when closing, stop when opening
2
Stop when closing and reverse when opening
3
Reverse when closing and opening
4
Stop when closing and opening
S
C202 Type of power supply
0 - 5
0
0
3x400 V with neutral
1
3x230 V without neutral
2
1x230 V with neutral, asymmetric
3
3x400 V without neutral (see separate instructions)
4
1x230 V with neutral, Frequency converter (see separate instructions DB409
5
1x230 V with neutral, symmetric
C205
Load guard for personal protection active during the
closing movement
0-1
1
0
Disabled
1
Active
S
C211 Load guard delay
0.01-2.50 seconds
0.06
S
C212 Load guard, connection delay on start, all starts
0.1-2.5 seconds
1.0
S
C221 Motor protection delay
3.0-5.0 seconds
3.0
S
C230
*
Set motor power readout for personal protection,
motor 1
0.00 and 0.12-0.35 kW 0.20
C231
Motor power readout, motor 1
0.00-1.99 kW
S
C232 Set load guard limit for motor 1 opening
0.05-1.99 kW
0.70
S
C233 Set load guard limit for motor 1 closing
0.05-1.99 kW
0.70
S
C240
*
Set motor power readout for personal protection,
motor 2
0.00 and 0.12-0.35 kW 0.20
C241
Motor power readout, motor 2
0.00-1.99 kW
S
C242 Set load guard limit for motor 2 opening
0.05-1.99 kW
0.70
S
C243 Set load guard limit for motor 2 closing
0.05-1.99 kW
0.70
C251
Motor current readout, motor 1
0.0-20.0A
S
C252 Set motor current readout, motor 1 opening
0.0 and 0.5-6.0A
0,8
S
C253 Set motor current readout, motor 1 closing
0.0 and 0.5-6.0A
0,8
C261
Motor current readout, motor 2
0.0-20.0A
S
C262 Set motor current readout, motor 2 opening
0.0 and 0.5-6.0A
0,8
S
C263 Set motor current readout, motor 2 closing
0.0 and 0.5-6.0A
0,8
C271
Power factor readout motor 1
0.00-0.99 cos
φ
C281
Power factor readout motor 2
0.00-0.99 cos
φ
* = Not displayed if C202=4, frequency converter