INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
19
Instruction manual edition 1 for EP104 version 4.08
• Indications
To simplify commissioning and troubleshooting, LEDs are provided to indicate faults and the status of input signals, as shown
in the table below.
Colour
Indication
Active when
Yellow
START
Constant when control signal received, flashing when counting down for automatic
closing.
Slowly flashing when counting down channel C520.
Red
M1
A constant LED means that the load guard setting has been exceeded, and a flashing
LED means that the load guard has been triggered for motor 1.
M2
A constant LED means that the load guard setting has been exceeded, and a flashing
LED means that the load guard has been triggered for motor 2.
SE.C1
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
SE.C2
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
SE.O1
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
SE.O2
A constant LED means that the safety edge has been activated, and a flashing LED
means that the safety edge has been reset.
Yellow
LOOP2
Vehicle loop 2 activated
LOOP1
Vehicle loop 1 activated
L.C2
Motor 2 not finished closing, extinguished in closed position, flashing means the input
is not programmed, quick flashing means hold-to-run without limit switch
L.O2
Motor 2 not finished opening, extinguished in closed position, flashing means the
input is not programmed, quick flashing means hold-to-run without limit switch
L.C1
Motor 1 not finished closing, extinguished in closed position, flashing means the input
is not programmed, quick flashing means hold-to-run without limit switch
L.O1
Motor 1 not finished opening, extinguished in closed position, flashing means the
input is not programmed, quick flashing means hold-to-run without limit switch
Green
PHOTO
Photocell not activated, circuit closed
Yellow
OPEN
Signal from internal button – open
CLOSE
Signal from internal button – close
INP6
Signal on programmable input 6, closed circuit between terminals 25 & 27
INP5
Signal on programmable input 5, closed circuit between terminals 25 & 26
INP4
Signal on programmable input 4, closed circuit between terminals 22 & 24
INP3
Signal on programmable input 3, closed circuit between terminals 22 & 23
INP2
Signal on programmable input 2, closed circuit between terminals 19 & 21
INP1
Signal on programmable input 1, closed circuit between terminals 19 & 20
Green
STOP
Stop not activated, circuit closed - OK
SAFE
Internal safety circuit – OK
Green
12 V
Voltage 12VDC - OK
24V
Voltage 12VDC - OK
Indications in top right-hand corner
Yellow
CLOSE2
Contactor for closing movement activated – motor 2
OPEN2
Contactor for opening movement activated – motor 2
CLOSE1
Contactor for closing movement activated – motor 1
OPEN1
Contactor for opening movement activated – motor 1
Содержание EP104