INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
11
Instruction manual edition 1 for EP104 version 4.08
Installing the EP104 PCB
If you are installing the PCB in a dedicated enclosure, you must follow the instructions below. Otherwise, the requirements
of the applicable EU directive will not be met, FAAC Nordic's declaration of conformity will not be valid and the product
will not be authorised for use. If the PCB is installed elsewhere, the installer is responsible for obtaining CE approval for the
control system in its entirety.
• Authorisation
!
Persons installing the PCB in an enclosure must be trained and authorised for the particular task.
• Enclosure
The PCB must be installed in an enclosure designed for the surrounding environment, and must protect the electronics from
moisture, dust and contact.
!
The enclosure must provide protection to class IP54 or better and must be designed for screw fixing to a wall or bracket.
For outdoor use, or if there is a risk of condensation in the enclosure, a heating element must be used.
• Installing the PCB
The PCB must be secured to a metal plate. The PCB dimensions are shown below.
Use the screws, spacers and washers provided to fix the PCB as illustrated.
!
If the fixing plate is painted, scrape off the paint around the holes to ensure good electrical contact between the earth
bar, spacers and the plate.
Fit the earth bar to the fixing plate, for connecting the external earth.
12.7
188
223.5
30.4
12.7
189.2
163.8
Metal screw M4
EP104 PCB
Metal spacer, minimum 10mm
Metal washer
Mounting plate in metal
twith M4 thread
Earth bar
Ø 4.5 (4x)
Содержание EP104