Страница 1: ...INSTRUCTION MANUALS Tensioned Cosmopolitan Series...
Страница 2: ...Table of Contents Tensioned Cosmopolitan Tensioned Cosmopolitan over 12 W...
Страница 3: ...3 INSTRUCTION MANUAL Tensioned Cosmopolitan...
Страница 4: ...iance is used subsequently 11 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structu...
Страница 5: ...all Installation Overall Length of Case Between Hanger Eyes Overall Length of Slat Slat Picture Surface Enclosure Cover 3 8 Diameter For Ceiling Mounting 7 8 Diameter Opening For Electrical Settings 1...
Страница 6: ...s le papier d emballage ou le ruban adh sif avec un couteau ou un outil tranchant Retirez la main 2 Install electrical hook up that applies to your unit Make sure to review your Electrical Installatio...
Страница 7: ...ver tighten fasteners or damage may occur 3 Attach screen securely to studding or other solid surface never to plaster only 4 MAKE SURE SCREEN IS MOUNTED LEVEL Ceiling Mounting 1 Heavy screw hooks may...
Страница 8: ...low Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp Operating Switch And Plate Furnished With Screen SPDT With Center Off In Multiple Control Installations This Switch Is Replaced By The Low Vo...
Страница 9: ...using the dry contact Up Down and Common connections The control panel must provide a momentary dry contact closure of at least 1 2 second 1 Use 3 conductor 20 24 gauge wire to connect the control pan...
Страница 10: ...e Common NOTE Must be wired to conform to local wiring code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to op...
Страница 11: ...by using the dry contact Up Down and Common connections The control panel must provide a momentary dry contact closure of at least 1 2 second 1 Use 3 conductor 20 24 gauge wire to connect the control...
Страница 12: ...and DOWN to the limit adjustment wall switch IMPORTANT NOTE The European style wall switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to locate t...
Страница 13: ...e top See the specification data sheet for details ATTENTION N effectuez pas de r glage pour obtenir un d roulement sup rieur celui command Au moins 1 1 2 tour de toile doit tre maintenu sur le cylind...
Страница 14: ...green This will put the motor in limit set mode Turn the wall switch over and use the up button on front of switch Press and hold until the desired travel position is reached If you travel to far up y...
Страница 15: ...button on screen switch and screen will stop if in movement 3 Press UP button on screen switch and screen will retract upward into case Up Button Stop Button Down Button Up Button Down Button European...
Страница 16: ...oken wire in the up or down position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Temporary bi...
Страница 17: ...wing evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall b...
Страница 18: ...ective owners All patents are protected under existing designations Other patents pending FOR YOUR IMAGE legrandav com USA P 866 977 3901 E av da lite support legrand com CANADA P 877 345 4329 E av da...
Страница 19: ...19 INSTRUCTION MANUAL Tensioned Cosmopolitan over 12 W...
Страница 20: ...efore installing the component 7 Use this projection screen only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer Save These Instructi...
Страница 21: ...unt 1 Be sure the ceiling has adequate reinforcement to attach the screen brackets 2 The ceiling brackets are pre attached to the wall mount bracket using 5 16 x 3 4 bolts washers and nuts The bracket...
Страница 22: ...es an optional low voltage control must be used This Switch Can Not be used with LVC 120V Wiring Diagram For Standard Wall Switch SPDT Switch with Center Off AC Common AC Hot 120VAC 60HZ Black Yellow...
Страница 23: ...using the dry contact Up Down and Common connections The control panel must provide a momentary dry contact closure of at least 1 2 second 1 Use 3 conductor 20 24 gauge wire to connect the control pan...
Страница 24: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control inst...
Страница 25: ...by using the dry contact Up Down and Common connections The control panel must provide a momentary dry contact closure of at least 1 2 second 1 Use 3 conductor 20 24 gauge wire to connect the control...
Страница 26: ...d DOWN to the limit adjustment wall switch IMPORTANT NOTE The European style wall switch is for operation only and CANNOT be used to make limit switch adjustments Therefore it is advised to locate the...
Страница 27: ...drop Run the screen down to test the stop position If the screen does not drop enough raise the screen about one foot and adjust the limit switch again Repeat until the desired position is set Do not...
Страница 28: ...conds the LED on the back of the wall switch will turn off the motor will return to run mode and no changes will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up lim...
Страница 29: ...he down or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Repla...
Страница 30: ...service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da...
Страница 31: ...spective owners All patents are protected under existing designations Other patents pending FOR YOUR IMAGE legrandav com USA P 866 977 3901 E av da lite support legrand com CANADA P 877 345 4329 E av...