Ascender Electrol® Installation

 

WARNING: To prevent electrical shock or damage to the low voltage control (LVC), do not apply power to the LVC until all 

connections are complete. Make sure power is turned off on all wires before making connections.

 

AVERTISSEMENT: pour éviter tout choc électrique ou d'endommager le tableau de contrôle basse tension, n'alimentez ce dernier 

qu'une fois tous les branchements effectués. Vérifiez qu'aucun câble n'est alimenté avant d'effectuer les branchements.

LOW VOLTAGE CONNECTIONS:

Wall Switch

1.  Install wall switch where desired.

2.  Use 2-conductor 20-24 gauge wire to extend the switch wire to 

the required length.

3.  Connect the wire from the switch to the wire labeled “wall switch”. 

Refer to Figure 3.

 

CAUTION: Never apply voltage to the wall switch lead or the 

LVC will be damaged.

 

ATTENTION: N'appliquez jamais une tension aux fils du 

commutateur mural sinon le tableau de contrôle basse 
tension sera endommagé.

Control Panel

A control panel may be connected to the LVC by using the wall 

switch wire lead. The control panel must provide a momentary, 
dry contact closure of at least 1/2 second.

1.  Use 2-conductor 20-24 gauge wire to connect the control panel 

to the wall switch lead.

2.  A momentary closure when the screen is down will be an “up” 

command.

3.  A momentary closure when the screen is fully extended will be a 

“down” command.

4.  A momentary closure while the screen is in motion will be a “stop” 

command.

 

CAUTION: Never apply voltage to the wall switch lead or the 

LVC will be damaged.

 

ATTENTION: N'appliquez jamais une tension aux fils du 

commutateur mural sinon le tableau de contrôle basse 
tension sera endommagé.

120V/240V Connections:

AC Power Source

1.  Refer to Figure 3 for electrical connections. Wiring designated as 

external is to be completed by installer conforming to local and 
national codes.

 

NOTE: Must be installed in accordance with the requirements 
of the Local Building Codes, the Canadian Electrical Code 
(CEC), CAN/CSA C22.1 and the National Electric Code (NEC), 

NFPA 70.  An appropriate disconnect device shall be 
provided as part of the building installation.

2.  Use 14-18 gauge wire to connect power to the LVC wires labeled 

“AC power input”. Refer to Figure 3.

3.  Connect the building ground wire to the ground lug on the metal 

housing.

Optional Wireless Remote Connections:

Radio Frequency Remote

1.  Remove the center cover plate of the LVC box.

2.  Route the receiver wire through the round plastic bushing and 

plug it into the onboard socket marked “EYE”. Refer to Figure 3.

Infrared Remote

1.  Remove the center cover plate of the LVC box.

2.  Route the receiver wire through the round plastic bushing and 

plug it into the onboard socket marked “EYE”. Refer to Figure 3.

Содержание Ascender Electrol

Страница 1: ...INSTRUCTION BOOK FOR Ascender Electrol ...

Страница 2: ...appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons Save These Instructions 1 The Ascender screen must be installed on a flat level surface 2 Remove the whi...

Страница 3: ...ommended hardware is 12 x 2 L wood screws Figure 1 Screw Box Into Floor Stud Floor Floor Box Frame Support Figure 1 Figure 2 2 For installations where the Ascender will be recessed into the floor the box must be secured in at least six places recommended hardware is 12 x 2 L wood screws Figure2 1 The Ascender screen can be operated by the included wall switch or by optional remote controls IRor RF...

Страница 4: ...en is down will be an up command 3 A momentary closure when the screen is fully extended will be a down command 4 A momentary closure while the screen is in motion will be a stop command CAUTION Never apply voltage to the wall switch lead or the LVC will be damaged ATTENTION N appliquez jamais une tension aux fils du commutateur mural sinon le tableau de contrôle basse tension sera endommagé 120V ...

Страница 5: ...te Common Single Pull Single Throw Momentary Contact Switch Up Stop Down Off Up Stop Down Off Black White Common Black Not Used Figure 3b Power Input 240 VAC 50 HZ Green Yellow Ground Single Pull Single Throw Momentary Contact Switch Door Microswitch Motor 240V Wiring Diagram Brown Up Black Down Blue Common Blue Common Brown Hot Green Yellow Ground Not Used Optional IR Or RF Connection White Commo...

Страница 6: ...eat until the desired position is set To Adjust The Down Position 1 Raise the screen about one foot and stop Turn the red limit adjuster counterclockwise one quarter turn to increase the down travel CAUTION Do not adjust the screen down too far This will strain the motor and screen The lid of the box should just close when the motor stops ATTENTION Ne déroulez pas trop l écran Cela forcera le mote...

Страница 7: ...wer to operating switch or junction Check above Tighten all loose wire connections Correct any improper connections Up Position Check for power across black and white leads Power at junction box Thermal overload tripped Let motor cool down for 15 minutes Try again Broken wire in the up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace ...

Страница 8: ...o Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNES...

Отзывы: