2.4. Monitoring
The real-time performance of NetDefendOS can be monitored in a number of ways. They are:
•
NetDefendOS real-time monitor alerts.
•
The NetDefendOS link monitor.
•
Monitoring through an SNMP client.
•
Hardware monitoring for specific hardware models.
2.4.1. Real-time Monitor Alerts
A number of NetDefendOS statistical values can graphically monitored through the
Real-time
Monitoring
feature.
Real-time Monitor Alert
thresholds can be specified in NetDefendOS for any of
these monitored values so that they can have a maximum and/or a minimum numerical
threshold.
Should a specified maximum or minimum threshold be crossed, NetDefendOS will automatically
generate a log message which will be sent to all configured log receivers. All such log messages
belong to the REALTIMEMONITOR message category which has the identity number 54.
The log message identity will therefore take the form 054XXXXX where XXXXX represents the
position of the statistic generating the event in the list of alert rules. A log message with identity
05400003, for example, identifies the third rule in the rule list.
Monitor Alert Rules
Each
Monitor Alert Rule
consists of the following fields:
Name
User assigned name for the rule.
Sample time
The interval in seconds between checking the statistic.
Low threshold
The lower threshold (if specified).
High threshold
A higher threshold (if specified).
Continuous
This determines if an event is also generated when the threshold is
crossed in the other direction. In other words, the statistic moves back to
within acceptable limits. This field can be Yes or No.
Backoff
The minimum number of seconds between consecutive
Monitor Threshold
Rule
log messages. This value can be useful in preventing a flood of log
messages when a statistic is repeatedly passing a threshold and then
receding from it again.
2.4.2. The Link Monitor
Overview
The
Link Monitor
is a NetDefendOS feature that allows monitoring of the connectivity to one or
more IP addresses external to the NetDefend Firewall. This monitoring is done using standard
Chapter 2: Management and Maintenance
103
Содержание NetDefendOS
Страница 30: ...Figure 1 3 Packet Flow Schematic Part III Chapter 1 NetDefendOS Overview 30 ...
Страница 32: ...Chapter 1 NetDefendOS Overview 32 ...
Страница 144: ...Chapter 2 Management and Maintenance 144 ...
Страница 220: ... Enable DHCP passthrough Enable L2 passthrough for non IP protocols 4 Click OK Chapter 3 Fundamentals 220 ...
Страница 267: ... SourceNetwork lannet DestinationInterface any DestinationNetwork all nets 4 Click OK Chapter 3 Fundamentals 267 ...
Страница 284: ...Chapter 3 Fundamentals 284 ...
Страница 360: ...The ospf command options are fully described in the separate NetDefendOS CLI Reference Guide Chapter 4 Routing 360 ...
Страница 392: ...Chapter 4 Routing 392 ...
Страница 396: ...Web Interface 1 Go to Network Ethernet If1 2 Select Enable DHCP 3 Click OK Chapter 5 DHCP Services 396 ...
Страница 419: ... Host 2001 DB8 1 MAC 00 90 12 13 14 15 5 Click OK Chapter 5 DHCP Services 419 ...
Страница 420: ...Chapter 5 DHCP Services 420 ...
Страница 424: ...2 Now enter Name lan_Access Action Expect Interface lan Network lannet 3 Click OK Chapter 6 Security Mechanisms 424 ...
Страница 573: ...Chapter 6 Security Mechanisms 573 ...
Страница 575: ...This section describes and provides examples of configuring NAT and SAT rules Chapter 7 Address Translation 575 ...
Страница 607: ...Chapter 7 Address Translation 607 ...
Страница 666: ...Chapter 8 User Authentication 666 ...
Страница 775: ...Chapter 9 VPN 775 ...
Страница 819: ...Chapter 10 Traffic Management 819 ...
Страница 842: ...Chapter 11 High Availability 842 ...
Страница 866: ...Default Enabled Chapter 13 Advanced Settings 866 ...
Страница 879: ...Chapter 13 Advanced Settings 879 ...