background image

DIS-200G Series Layer 2 Gigabit Industrial Smart Managed Switch Hardware Installation Guide 

11 

LED Indicators 

All Switches 

Below is an overview of the LED indicators present on all switch models in the DIS-200G series. 

 

Figure 1-4 LED indicators for all DIS-200G Series switches 

 

 

LED 

 

Description 

SYS 

Solid green 

The DIS-200G switch is on and accepting web connections. 

Blinking green 

A firmware update is in progress. 

Solid amber 

The DIS-200G switch is not ready for communication. 

Blinking amber 

The DIS-200G switch is booting up, or PoE has failed during system 
operation (DIS-200G-12PS/PSW PoE models only). 

ALM 

Solid amber 

The power supply to the DIS-200G has failed. 

PWR 1 

Solid green 

Power source 1 is connected. 

PWR 2

 

Solid green 

Power source 2 is connected. 

PWR 3

 

Solid green 

Power source 3 is connected. 

Ports 11 - 12 

Solid green 

Port is connected at 1 Gbps. 

Blinking green 

There is activity on the port at 1 Gbps. 

Содержание DIS-200G-12S

Страница 1: ......

Страница 2: ...either the entities claiming the marks and names or their products D Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own 2018 D Link Corporation All rights reserved March 2018 SFP Mini GBIC XENPAK and XFP Regulatory Compliance Networks pluggable optical modules meet the following regulatory requirements Class 1 IEC EN60825 1 2007 2nd Edition or late...

Страница 3: ...r example press the Enter key Blue Courier Font This convention is used to represent a Command Line Interface CLI example Notes and Cautions NOTE A note indicates important information that helps you make better use of your device CAUTION A caution indicates a potential for property damage personal injury or death Safety Instructions Please pay careful attention to the following safety guidelines ...

Страница 4: ...ings limit for the extension cable or power strip To help protect the system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply UPS Position system cables and power cables carefully Route cables so that they cannot be stepped on or tripped over Be sure that nothing rests on any cables Do not modify power cables ...

Страница 5: ...Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Ensure that proper airflow is provided to components in the rack Do not step on or stand on any component when servicing other components in a rack CAUTION Never defeat the ground conductor or operate the equipment in the absence of a suitably i...

Страница 6: ... Switch on a Wall 14 Using the Wall Mounting Brackets 14 Using the Screw Hooks 15 Installing the Switch into a Rack 16 Grounding the Switch 16 Installing Transceivers into the Transceiver Ports 17 Connecting to a Power Source 18 Using the Power Adapter Optional 18 Using the Terminal Connections 18 Redundant Power Design 19 3 Switch Connections 20 Switch to an End Node 20 Switch to Another Switch 2...

Страница 7: ...he Web UI 32 Web Pages 32 Appendix A Technical Specifications 34 General 34 Software Features 35 Supported Accessories 37 Supported SFP Transceivers 37 Optional Accessories 37 Appendix B Cables and Connectors 38 Ethernet Cable 38 Console Cable RJ 45 to RS 232 39 Technical Support 40 Regulatory Statements 41 ...

Страница 8: ...illance settings The DIS 200G Series furthermore integrates advanced management and security functions to provide a complete solution The DIS 200G Series consists of the following switch models DIS 200G 12S DIS 200G 12SW DIS 200G 12PS and DIS 200G 12PSW Some features throughout this guide will apply to all the switches within the DIS 200G Series while certain feature are exclusive to specific mode...

Страница 9: ...hich is used to connect to the DIS 200G switch using a RJ 45 to serial cable 3 Ports 1 10 These are 10 100 1000 Mbps ports that can be used to connect to any device using a standard Category 5 5e RJ 45 Ethernet cable 4 Ports 11 12 These are 1 Gbps SFP ports that can be used to connect to other switches using compatible SFP adapters and fiber cable For a complete list of SFP transceivers that are c...

Страница 10: ...wer adapter to the switch Top Panel Components Figure 1 3 Top panel view of the DIS 200G Series switches Ports that can be found on the top panel of this switch are listed in the table below LED Description 1 Switch Ground This is used to connect the switch to ground 2 Terminal Block This is used to connect the switch to external power sources and an alarm relay ...

Страница 11: ...nections Blinking green A firmware update is in progress Solid amber The DIS 200G switch is not ready for communication Blinking amber The DIS 200G switch is booting up or PoE has failed during system operation DIS 200G 12PS PSW PoE models only 2 ALM Solid amber The power supply to the DIS 200G has failed 3 PWR 1 Solid green Power source 1 is connected 4 PWR 2 Solid green Power source 2 is connect...

Страница 12: ...The power budget is between 25 and 0 but still has more than 15 4 W of power remaining Blinking amber The power budget is between 25 and 0 and has less than 15 4 W of power remaining 2 Left Ports 1 10 Solid green Port is connected at 1 Gbps Blinking green There is activity on the port at 1 Gbps Solid amber Port is connected at 10 100 Mbps Blinking amber There is activity on the port at 10 100 Mbps...

Страница 13: ...Solid green Port is connected at 1 Gbps Blinking green The port is undergoing cable diagnostics Solid amber Port is connected at 10 100 Mbps 2 Right Ports 1 8 Blinking green There is activity on the port at 1 Gbps Blinking amber There is activity on the port at 10 100 Mbps 3 Left Ports 9 10 Solid green Port is connected at 1 Gbps Blinking green There is activity on the port at 1 Gbps Solid amber P...

Страница 14: ... please ensure that the DIN rail is level and that the DIN rail mounting kit is installed correctly on the DIS 200G switch Use the following instructions to install the DIS 200G switch on a DIN rail 1 With the back of the switch facing the DIN rail lower the top part of the rail mounting kit onto the DIN rail 2 Push the switch vertically down and rotate the bottom of the switch towards the DIN rai...

Страница 15: ...d secure the switch to the wall using the appropriate screws for the wall anchors Using the Screw Hooks Use the following instructions to mount the DIS 200G switch on a wall using the screw hooks on the underneath of the switch 1 Mark two points on the surface where you wish to mount the switch 60 mm apart 2 Drill holes on the marks and insert wall anchors appropriate for the material of the wall ...

Страница 16: ... the provided screws Figure 2 3 Attaching rack mount brackets to the Switch 2 Use the screws that were provided with the rack to install the switch in the rack Figure 2 4 Installing the Switch in a Rack Make sure that there is adequate space around the switch to allow for proper air flow ventilation and cooling Grounding the Switch To use the DIS 200G switch safely it needs to be grounded Please c...

Страница 17: ...onnect various other networking devices to this switch that do not support the standard RJ 45 wiring connection These ports are generally used to connect this switch to optical fiber connections and can be used to connect devices to the switch over great distances The maximum distance that the RJ 45 wiring connection can reach is 100 meters Fiber optic connections can span several kilometers The f...

Страница 18: ...nector on the back of the switch Connect the other end of the power adapter to a main power source Figure 2 6 Connecting the power adapter Using the Terminal Connections Before proceeding ensure that all power sources have been disconnected from the switch including the power source you are wiring to the switch Use the following instructions to power the switch using the terminal connections 1 Bef...

Страница 19: ...automatically be designated as the main power source Any additional power sources connected afterwards will be designated redundant power sources When one of the power source is behaving abnormally or fails the alarm relay and ALM LED will be triggered There is no order or hierarchy for determining active and redundant power sources For example if the first power source is connected to PWR 2 the s...

Страница 20: ...icate that network activity is taking place on that port The diagram below displays a typical end node connected to the switch Figure 3 1 Connecting the Switch to an End Node Switch to Another Switch The switch can be used to connect to any other switch or hub in the network This network topology is used when the switch does not have enough ports to cater for all the end nodes in the network There...

Страница 21: ...DIS 200G Series Layer 2 Gigabit Industrial Smart Managed Switch Hardware Installation Guide 21 Figure 3 2 Connecting the Switch to another switch hub ...

Страница 22: ...has been successfully installed you can begin configuration monitor the LED panel and display graphical statistics using a web browser Supported browsers include Microsoft Internet Explorer Firefox Chrome and Safari You need the following equipment to access the web UI of your device A PC with an RJ 45 Ethernet connection A standard Ethernet cable 1 Connect the Ethernet cable to any of the ports o...

Страница 23: ...ole port on the switch These are widely available and can be easily downloaded from the Internet You need the following equipment to use the console port of your device A PC with both an RS 232 serial port and terminal emulation software A RS 232 Serial to RJ 45 console cable included in this package Use the following steps to connect to the switch s console port 1 Connect the RS 232 serial interf...

Страница 24: ...appear in the terminal 3 tests completed successfully RedBoot fis load d managed Image loaded from 0x80040000 0xB12d1d30 RedBoot go Press ENTER to get started After the boot sequence has been completed the console login screen will be displayed Connecting to the Switch for the First Time The switch supports user based security that can prevent unauthorized users from accessing the switch or changi...

Страница 25: ...nt for the switch called user Switch enable Switch configure terminal Switch config username user password pass1234 Switch config In the example above 1 At the CLI command prompt enter the enable command to enter the Privileged EXEC Mode Press Enter 2 Enter the configure terminal command to enter the Global Configuration Mode Press Enter 3 Enter the username User password pass1234 command Press En...

Страница 26: ... com to download the software and get more information The Simple Network Management Protocol SNMP is an OSI Layer 7 Application Layer protocol designed specifically for managing and monitoring network devices The SNMP protocol enables Network Management Station NMS to read and modify the settings of gateways routers switches and other network devices Use SNMP to configure system features for prop...

Страница 27: ...ed or restricted are defined using the Object Identifier OID associated with a specific MIB An additional layer of security is available for SNMPv3 in that SNMP messages may be encrypted Traps Traps are messages that are sent by an SNMP enabled device to the NMS and can be used to alert network personnel of events that occur on the switch The events can be as serious as a reboot someone accidental...

Страница 28: ...g web browsers are supported Internet Explorer Firefox Google Chrome Safari Logging into the Web UI To access the Web UI open a standard web browser enter the switch s default IP address 10 90 90 90 into the address bar of the browser and press the ENTER key After pressing the ENTER key the following authentication window should appear as shown below Figure 5 1 Web UI Login Window When connecting ...

Страница 29: ...Select this option to obtain IP address settings from a DHCP server IP Address If you selected Static enter the IP address of the switch here Netmask If you selected Static select the netmask here Gateway If you selected Static enter the default gateway IP address here Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit button to discard the change...

Страница 30: ...sword Enter the new password again for confirmation Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit button to discard the changes made exit the Smart Wizard and continue to the Web UI Click the Back button to discard the changes made and return to the previous step Click the Next button to accept the changes made and continue to the next step S...

Страница 31: ...Click the Exit button to discard the changes made exit the Smart Wizard and continue to the Web UI Click the Back button to discard the changes made and return to the previous step Click the Apply Save button to accept the changes made and continue to the Web UI Web User Interface Web UI When completing skipping or exiting the Smart Wizard when logging into to the switch you will enter the main ma...

Страница 32: ...in them to display windows AREA 2 Presents switch status based on user selection and the entry of configuration data In addition a hyperlink to Settings is offered to enable quick Gateway configuration AREA 3 Presents a toolbar used to access function like Save Tools the Wizard and Online Help Web Pages In area 1 mentioned above the following main folders will be available for selecting Folder Nam...

Страница 33: ... this folder Security Features regarding the switch s security can be viewed and configured in this folder OAM Features regarding the switch s Operations Administration and Maintenance OAM can be viewed and configured in this folder Monitoring The switch s configuration and statistics can be viewed and configured in this folder Green Features regarding the D Link Green Technology can be viewed and...

Страница 34: ...a Interface Exchange Auto MDI MDIX adjustment for all twisted pair ports Performance Switching Capacity 24 Gbps Maximum Forwarding Rate 17 85 Mpps MAC Address Table Size Up to 8K entries Transmission Method Store and forward PoE PoE Standards N A N A IEEE 802 3af at IEEE 802 3af at PoE Capable Ports N A N A Ports 1 to 8 Ports 1 to 8 PoE Power Budget N A N A Max 240 W1 Max 240 W1 Physical Diagnosti...

Страница 35: ...40 to 65 C 40 to 149 F 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Operating Humidity 0 to 95 RH non condensing Storage Humidity 0 to 95 RH non condensing Material IP30 rated metal casing Installation DIN rail wall rack mountable MTBF 276 773 hours 219 314 hours 213 112 hours 156 452 hours Certifications CE FCC BSMI Safety UL60950 1 EMI CISPR 22 FCC Part 15B Class A EMS EN 61...

Страница 36: ...es per port Queue handling Strict Priority Queue SPQ Weighted Round Robin WRR Port based bandwidth control rate limiting Ingress 8 kbps Egress 64 kbps Security D Link Safeguard Traffic segmentation Broadcast Multicast Unknown Unicast Storm Control DoS attack prevention SSL Port security AAA Web based access control RADIUS Management Web based UI supports IPv4 IPv6 Client based D Link Network Assis...

Страница 37: ... Transceivers DEM 310GT 1000BASE LX single mode 10 km 0 to 70 C operating temperature DIS S310LX 1000BASE LX single mode 10 km 40 to 85 C operating temperature DEM 311GT 1000BASE SX multi mode 550 m 0 to 70 C operating temperature DIS S301SX 1000BASE SX multi mode 550 m 40 to 85 C operating temperature DEM 312GT2 1000BASE SX multi mode 2 km 0 to 70 C operating temperature DIS S302SX 1000BASE SX mu...

Страница 38: ...eview these products for matching cable pin assignment The following diagrams and tables show the standard RJ 45 socket connector and their pin assignments Figure B 1 Standard RJ45 socket and connector pin assignments RJ 45 Pin Assignment Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD tr...

Страница 39: ... to the console port of the switch to access the command line interface The following diagram and table show the standard RJ 45 to RS 232 cable and pin assignments Figure B 2 Console to RJ45 Cable Contact Console DB9 RS232 RJ 45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Страница 40: ...aged Switch User Manual This manual describes the general installation and how to connect the switch in various scenarios Online Support If there are any issues that are not in the user manual please visit http support dlink com which will direct you to your appropriate local D Link support website Warranty Information Visit http warranty dlink com to view the D Link Limited Lifetime Warranty info...

Страница 41: ...eration is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Innovation Science and Economic Development Canada ISED Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la n...

Страница 42: ...ärme erzeugen Trennen Sie das Produkt immer von der Stromzufuhr bevor Sie es reinigen und verwenden Sie dazu ausschließlich ein trockenes fusselfreies Tuch CONSIGNES DE SÉCURITÉ Les consignes générales de sécurité ci après sont fournies afin d assurer votre sécurité personnelle et de protéger le produit d éventuels dommages Veuillez consulter les consignes d utilisation du produit pour plus de dét...

Страница 43: ...i calore Scollegare sempre il prodotto dalla presa elettrica prima di pulirlo e usare solo un panno asciutto che non lasci filacce VEILIGHEIDSINFORMATIE De volgende algemene veiligheidsinformatie werd verstrekt om uw eigen persoonlijke veiligheid te waarborgen en uw product te beschermen tegen mogelijke schade Denk eraan om de gebruikersinstructies van het product te raadplegen voor meer informati...

Страница 44: ...ung helfen Sie die Umwelt zu schonen und die menschliche Gesundheit zu schützen D Link und die Umwelt D Link ist sich den möglichen Auswirkungen seiner Geschäftstätigkeiten und seiner Produkte auf die Umwelt bewusst und fühlt sich verpflichtet diese entsprechend zu mindern Zu diesem Zweck entwickelt und stellt D Link seine Produkte mit dem Ziel größtmöglicher Umweltfreundlichkeit her und verwendet...

Страница 45: ...e visitate il sito all indirizzo www dlinkgreen com NEDERLANDS NL Dit symbool op het product of de verpakking betekent dat dit product volgens de plaatselijke wetgeving niet mag worden weggegooid met het huishoudelijk afval maar voor recyclage moeten worden ingeleverd Zodra het product het einde van de levensduur heeft bereikt dient u het naar een inzamelpunt te brengen dat hiertoe werd aangeduid ...

Страница 46: ...mékeinkről és csomagolásainkról további információkat a www dlinkgreen com weboldalon tudhat meg NORSK NO Dette symbolet på produktet eller forpakningen betyr at dette produktet ifølge lokale lover og forskrifter ikke skal kastes sammen med husholdningsavfall men leveres inn til gjenvinning Vennligst ta det til et innsamlingssted anvist av lokale myndigheter når det er kommet til slutten av leveti...

Страница 47: ...per du till att bevara miljön och skydda människors hälsa D Link och miljön På D Link förstår vi och är fast beslutna att minska den påverkan våra verksamheter och produkter kan ha på miljön För att minska denna påverkan utformar och bygger D Link sina produkter för att de ska vara så miljövänliga som möjligt genom att använda återvinningsbara material med låg gifthalt i både produkter och förpack...

Отзывы: