4 Configuration
DGS-1210 series Metro Ethernet Managed Switch User Manual
40
NOTE:
The time must be set after current time,
otherwise it will take effect on the next cycle time.
System > Power Saving
The Power Saving mode feature reduces power consumption automatically when the RJ-45 port is link down
or the connected devices are turned off. Less power will be consumed also when the short cable is used
(less than 20 meters).
By reducing power consumption, less heat is produced, resulting in extended product life and lower
operating costs. By default, the Cable Length Detection and Link Status Detection are enabled. Click
Apply
to make the change effective.
Figure 4.47 – System > Power Saving
Advanced Power Saving Settings:
Type:
Specifies the Power Saving type to be LED Shut-off, Port Shut-off, Port Standby or System
Hibernation.
LED Shut-off -
The LED Shut-off gets high priority. If the user select LED Shut-off, the profile
function will not take effect. It means the LED cannot be turned on after Time Profile time’s up when
the state is disabled. On the contrary, if the LED is enabled, the Time Profile function will work.
Port Shut-off -
The Port Shut-off state has high priority (the priority rule is the same as LED.)
Therefore, if the Port Shut-off sate is already disabled the Time Profile function will not take effect.
System Hibernation -
In this mode, switches get most power-saving figures since main chipsets
(both MAC and PHY) are disabled for all ports, and energy required to power the CPU is minimal.
State:
Specifies the power saving state to be Enabled or Disabled.
Time Profile 1:
Specifies the time profile or None.
Time Profile 2:
Specifies the time profile or None.
Port:
Specifies the ports to be configure of the Power Saving.
Click
Select All
configure all ports, or click
Clear
to uncheck all port. Then Click Apply to make the
configurations take effect.
System > IEEE802.3az EEE Settings
The IEEE 802.3 EEE standard defines mechanisms and protocols intended to reduce the energy
consumption of network links during periods of low utilization, by transitioning interfaces into a low-power
state without interrupting the network connection. The transmitted and received sides should be
IEEE802.3az EEE compliance. By default, the switch enabled the 802.3az EEE function. Users can disable
this feature by individual port via the IEEE802.3az EEE setting page.