4 Configuration
DGS-1210 series Metro Ethernet Managed Switch User Manual
3
3
9
9
System > System Log Configuration > System Log Server
The user can send Syslog messages to up to four designated servers using the
System Log Server
. It
supports maximum 500 system log entries. To set the System Log Server configuration, click
Apply
.
Figure 4.45 - System > System Log Configuration > System Log Server
Server ID:
Specifies the Server ID. The field range is 1-4.
Severity:
Specifies the minimum severity from which warning messages are sent to the server. There are
three levels. When a severity level is selected, all severity level choices above the selection are selected
automatically. The possible levels are:
Warning -
The lowest level of a device warning. The device is functioning, but an operational
problem has occurred.
Informational -
Provides device information.
All -
Displays all levels of system logs.
Server IPv4 Address:
Specifies the IPv4 address of the system log server.
Server IPv6 Address:
Specifies the IPv6 address of the system log server.
Facility:
Specifies an application from which system logs are sent to the remote server. Only one facility can
be assigned to a single server. If a second facility level is assigned, the first facility is overwritten. There are
up to eight facilities can be assigned (Local 0 ~ Local 7).
UDP Port:
Specifies the UDP port to which the server logs are sent. The possible range is
6000 – 65535
,
and the default value is
514
.
Status:
Specifies the status is enable or disable.
System > Time Profile
The Time Profile page allows users to configure the time profile settings of the device.
Figure 4.46 – System > Time Profile Settings
Range Name:
Specifies the profile name for the time profile to be configured.
Date:
Select Date and specifies the
From Day
and
To Day
of the time profile.
Hours (HH MM):
Specifies the
Start Time
and
End Time.
Weekdays:
Specifies the work day for the time profile. Or tick
Select All Days
to select all days for the time
profile.
Click
Apply
to create a new time profile or click
Delete
to delete a time profile from the table.