DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
350
untag_source_port
– Adds a range of untagged source ports to the
multicast VLAN.The PVID of the untag source port will be
automatically changed to the multicast VLAN. It shall be only one
kind of source port, tag or untag for an ISM VLAN.
tag_member_port
– Specifies the tagged member port of the MLD
multicast VLAN.
state
– enable or disable multicast VLAN for the chosen VLAN.
replace_source_ipv6 <ipv6addr>
– With the MLD snooping function,
the MLD report packet sent by the host will be forwarded to the
source port. Before the forwarding of the packet, the source IP
address in the join packet needs to be replaced by this IPv6
address.
remap_priority
– Associates the remap priority value (
0
to
7
) with the
data traffic and is forwarded on the multicast VLAN. If
none
is
specified, the packet’s original priority will be used.The default
setting is
none
.
Restrictions
Only administrator, operator or power user–level users can issue
this command.
Example usage:
To config MLD multicast VLAN mv1:
DGS-1210-28MP/ME:5#
config mld_snooping multicast_vlan mv1 add member_port 1,3
state enable
Command: config mld_snooping multicast_vlan mv1 add member_port 1,3 state enable
Success.
DGS-1210-28MP/ME:5#
show mld_snooping multicast_vlan
Purpose
To to show the information of MLD multicast VLAN.
Syntax
show mld_snooping multicast_vlan <vlan_name 32>
Description
The
show mld_snooping multicast_vlan
command allows user to
show the information of an MLD multicast VLAN.
Parameters
<vlan_name 32> –
specifies that the mld snooping applies only to
this previously created VLAN.
Restrictions
None.
Example usage:
To show MLD multicast VLAN:
DGS-1210-28MP/ME:5# show mld_snooping multicast_vlan mv1
Command: show mld_snooping multicast_vlan mv1
Multicast VLAN Global State : Enabled
DGS-1210-28MP/ME:5#
delete mld_snooping multicast_vlan
Purpose
To to delete an MLD muticast VLAN.
Syntax
delete mld_snooping multicast_vlan [<vlan_name 32> | all]
Description
The
delete mld_snooping multicast_vlan
command allows user to
Содержание DGS-1210/ME series
Страница 61: ...DGS 1210 ME Metro Ethernet Switch CLI Reference Guide 41 Sending mail please wait Success DGS 1210 28MP ME 5 ...
Страница 186: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 166 DGS 1210 28MP ME 5 ...
Страница 190: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 170 Success DGS 1210 28MP ME 5 ...
Страница 386: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 366 Port Max Group 1 v6 256 3 v6 256 DGS 1210 28MP ME 5 ...