Страница 3: ...agement Options 7 Using Web based Management 7 Supported Web Browsers 7 Connecting to the Switch 7 Login Web based Management 8 Smart Wizard 8 Web based Management 8 SmartConsole Utility 8 SmartConsol...

Страница 4: ...ing 36 Configuration Port Mirroring 38 Configuration Power Saving 38 Configuration Loopback Detection 38 Configuration SNTP Settings Time Settings 39 Configuration SNTP Settings TimeZone Settings 40 C...

Страница 5: ...ccount admin password 62 Save 62 Appendix A Ethernet Technology 63 Gigabit Ethernet Technology 63 Fast Ethernet Technology 63 Switching Technology 63 Appendix B Technical Specifications 62 Hardware Sp...

Страница 6: ......

Страница 7: ...s Usage In this guide the term Switch first letter capitalized refers to the Smart Switch and switch first letter lower case refers to other Ethernet switches Some technologies refer to terms switch b...

Страница 8: ...imedia by prioritizing that traffic in network These functions allow switches to work seamlessly with VLAN and 802 1p traffic in the network Auto Voice VLAN will automatically place the voice traffic...

Страница 9: ...Watts Reset By pressing the Reset button the Switch will change back to the default configuration and all changes will be lost Mode By pressing the Mode button the Port LED will switch between Link A...

Страница 10: ...ch installation and operation it is recommended that you Visually inspect the power cord to see that it is secured fully to the AC power connector Make sure that there is proper heat dissipation and a...

Страница 11: ...operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D C...

Страница 12: ...tion D Link Web Smart Switch User Manual Figure 6 Plugging the switch into an outlet Power Failure As a precaution the switch should be unplugged in case of power failure When power is resumed plug th...

Страница 13: ...ing the SmartConsole Utility you do not need to change the IP address of your PC and it is easier to initialize multiple Smart Switches Please refer to the following installation instructions for the...

Страница 14: ...pears in the Monitor List This will automatically load the web configuration in your web browser When the following logon dialog box appears enter the password then click OK The default password is ad...

Страница 15: ...nd use the SmartConsole Utility to discover the Smart Switches Option 2 Follow these steps to install the SmartConsole Utility manually 1 Insert the Utility CD into your CD Rom DVD Rom Drive 2 From th...

Страница 16: ...Console Device List Figure 10 SmartConsole Utility SmartConsole Settings The SmartConsole Settings at the left has five icons Utility Settings Log Trap File and Help Utility Settings Click this icon t...

Страница 17: ...e 12 SmartConsole Log Trap Click this icon to launch the Trap window Click View Trap to show the events of the SmartConsole Utility and the device Date Time indicates when the trap message was receive...

Страница 18: ...of the Device List as default for the next time the SmartConsole Utility is used Monitor Save As Records the setting of the Device List in an appointed filename and file path Monitor Load Manually loa...

Страница 19: ...tons for the Device List Device Settings Select a switch from the Device List Click on this icon to launch the Device Settings window Here you can configure the Product Name IP Address Gateway Subnet...

Страница 20: ...rect password of the device and then click Upgrade The state will show OK after completion or Fail if the firmware upgrade fails or cannot be completed for any reason Figure 18 Firmware Upgrade CAUTIO...

Страница 21: ...he device in the device list Add Delete and Discover the device Click the Discovery button to display all of the Web Smart devices located in the same domain with the management PC Click the and inser...

Страница 22: ...ice product name System Name Displays the appointed device system name DHCP Specify if the device gets the IP address from a DHCP server Location Displays the location of the appointed device Trap IP...

Страница 23: ...Web Smart Switch If you do not plan to change anything click Exit to leave the Wizard and enter the Web Interface You can also skip it by clicking Don t show Smart Wizard next time for the next time...

Страница 24: ...nterface The default SNMP Setting is Disabled Click Enabled enter Community names and then click Apply to make it effective Read_Only Community Read only privilege allows authorized management station...

Страница 25: ...elect DHCP to have the switch obtain an IP address from a DHCP server in the network Figure 25 Configure System IP address in Smart Wizard NOTE Changing the system IP address will disconnect you from...

Страница 26: ...y choosing different functions in the Function Tree you can change all the settings in the Main Configuration Screen The main configuration screen will show the current status of your Switch by clicki...

Страница 27: ...n view or edit the log file by using text editor e g Notepad Figure 30 Save Log Tool Bar Tool Menu The Tool Menu offers global function controls such as Reset Reset System Reboot Device Configuration...

Страница 28: ...settings to your disk Click Browse to browse your inventories for a saved backup settings file Click Restore after selecting the backup settings file you want to restore TFTP TFTP Trivial File Transf...

Страница 29: ...k Backup to save the firmware to the TFTP server Click Upgrade after selecting the firmware file you want to restore CAUTION Do not disconnect the PC or remove the power cord from device until the upg...

Страница 30: ...5 Configuration D Link Web Smart Switch User Manual Figure 38 User Guide Micro Site 24...

Страница 31: ...iguration Spanning Tree STP Global Settings Default is disabled Port Mirroring Click Setting to link to Configuration Port Mirroring Default is disabled Storm Control Click Setting to link to Configur...

Страница 32: ...net mask is 255 0 0 0 System Information By entering a System Name and System Location the device can more easily be recognized through the SmartConsole Utility and from other Web Smart devices on the...

Страница 33: ...tate changes Firmware Upgrade State Information of firmware upgrade success or failure PoE Power On Off Event PoE port powering information PoE Power Error Event Information about PoE powering error P...

Страница 34: ...nected System SNMP Settings Simple Network Management Protocol SNMP is an OSI Layer 7 Application Layer protocol designed specifically for managing and monitoring network devices SNMP enables network...

Страница 35: ...ice Bootup Fiber Link Up Link Down Twisted Pair Link Up Link Down RSTP Port State Change Firmware Upgrade State Trap notification if POE Power On Off Trap notification if POE Power Error Trap notifica...

Страница 36: ...bytes tagged Default is disabled Select Enabled then click Apply to turn on the jumbo frame support 6 Figure 47 Configuration Jumbo Frame Configuration 802 1Q VLAN A VLAN is a group of ports that can...

Страница 37: ...ls or other shared resources in the shared VLAN This configuration is accomplished in three steps Enabling Asymmetric VLAN function Creating shared VLAN and access VLAN Configuring the PVID of access...

Страница 38: ...twork are Port 9 is connected to the server Port 10 is connected to the firewall The group of shared ports needs to be included for all the VLANs Ports 9 10 already belong to VLAN 1 therefore no chang...

Страница 39: ...AN in larger networks Note When Asymmetric VLAN is enabled IGMP Snooping Management VLAN and MAC address table will be reset to default Configuration 802 1Q Management VLAN The 802 1Q Management VLAN...

Страница 40: ...ing timer will start The port will be removed from the voice VLAN after the expiration of the voice VLAN aging timer Selectable range is from 1 to 120 hours and default is 1 hour From Port To Port A c...

Страница 41: ...onfigure one user defined OUI will take extra one ACL rule System will auto generate an ACL profile Profile ID 51 for all the Voice VLAN rules Select the OUI and press Add to the lower table to comple...

Страница 42: ...ated port group that is to add or subtract ports from the group at least one of the participating devices must designate LACP ports as active Both devices must support LACP Passive LACP ports that are...

Страница 43: ...re no Query control messages received for Router Port Purge Interval time the learned router port entry will be purged Default is 260 seconds Last Member Query Interval 1 25 sec The Last Member Query...

Страница 44: ...all ports into port mirroring None Turns off the mirroring of the port Click all to remove all ports from mirroring Configuration Power Saving The Power Saving mode feature reduces power consumption a...

Страница 45: ...e group of ports may be configured starting with the selected port State Use the drop down menu to toggle between Enabled and Disabled Default is Disabled Click Apply to implement changes made Configu...

Страница 46: ...ylight Saving Time Offset in Minutes Use this drop down menu to specify the amount of time that will constitute your local DST offset 30 60 90 or 120 minutes Time Zone Offset from GMT in HH MM Use the...

Страница 47: ...does not endlessly circulate through redundant paths in the network preventing the effective propagation of the new information Set by the Root Bridge this value will aid in determining that the Swit...

Страница 48: ...00000 Gigabit port 20000 Value 1 200000000 Define a value between 1 and 200000000 to determine the external cost The lower the number the greater the probability the port will be chosen to forward pac...

Страница 49: ...oot port to signal a topology change If set to True it stops the port from propagating received TCN and to other ports The default value is False Click Apply for the settings to take effect Click Refr...

Страница 50: ...ndwidth control for the selected ports QoS 802 1p DSCP Priority Settings QoS is an implementation of the IEEE 802 1p standard that allows network administrators to reserve bandwidth for important func...

Страница 51: ...reached its egress weight the system will process the packets in the next level even if there are remaining packets D Link Smart Switch system s weight of priority levels are 8 Highest 4 High 2 Mediu...

Страница 52: ...nown to the Switch prior to stopping auto learning processing from gaining access to the network A given ports or a range of ports dynamic MAC address learning can be stopped such that the current sou...

Страница 53: ...he number of seconds that the switch remains in the quiet state following a failed authentication exchange with the client Default is 80 seconds SuppTimeout 1 65535 sec This value determines timeout c...

Страница 54: ...ing for any of the uplink ports click On to enable this feature and then select the port s for auto learning to be disabled The Static MAC Address Setting table displays the static MAC addresses conne...

Страница 55: ...Number of packets transmitted successfully RxOK Number of packets received successfully TxError Number of transmitted packets resulting in error RxError Number of received packets resulting in error...

Страница 56: ...d Test Failed means some other errors occurred during cable diagnostics Please select the same port and test again Cable Fault Distance meters Indicates the distance of the cable fault from the Switch...

Страница 57: ...ss The ACL Configuration Wizard will aid with the creation of access profiles and ACL Rules The ACL Wizard will create the access rule and profile automatically The maximum usable profiles are 50 and...

Страница 58: ...t Enter a range of ports to be configured Press Apply for the settings to take effect NOTE Once the ACL rules conflict rules with the smaller rule ID will take higher priority NOTE Be careful when con...

Страница 59: ...ill be displayed 2 Selecting the field of interest will display the related columns in the lower part of the page Enter the filtering mask and click Create when done A filtering mask is to specify the...

Страница 60: ...the field of format is xx xx xx xx xx xx Source MAC Address Specify the Source MAC address the field of format is xx xx xx xx xx xx 802 1p Specify the 802 1p priority value Ether Type Specify the Eth...

Страница 61: ...les DGS 1210 10P follows the standard PSE Power Supply Equipment pinout Alternative A whereby power is sent out over pins 1 2 3 and 6 DGS 1210 10P works with all D Link 802 3af or 802 3at capable devi...

Страница 62: ...s 4 and Auto for the power limit Auto will negotiate and follow the classification from the PD power current based on the 802 3at standard User Define Check the box and input the power budget from 1 t...

Страница 63: ...n menu of From Day and To Day to define the date range Hours Select from drop down menu of Start Time and End Time to define the range of a day Note If the End Time is before the Start Time the End da...

Страница 64: ...nStatus becomes disabled until re initialization is attempted The default value is 2 seconds LLDP TX Delay 1 8192 This parameter indicates the delay between successive LLDP frame transmissions initiat...

Страница 65: ...d Password to log in The default user name and password is admin Note that the user name and password are case sensitive Press Enter in both the Username and Password fields The command prompt will ap...

Страница 66: ...oTFTP Specifies that the Switch s current settings will be uploaded to the TFTP server tftp ip address The IP address of the TFTP server filename The filename of the firmware or switch configuration f...

Страница 67: ...workstation The terminal interface sends five pings to the target station Syntax ping ipaddr Parameter Parameter Description ipaddr The IP address of the target station Reboot This command reboots the...

Страница 68: ...account admin password The command sets the administrator password Syntax config account admin password passwd Parameter Parameter Description passwd The new password of the administrator Save The co...

Страница 69: ...r unshielded twisted pair UTP cabling a flexible foundation for the next generation of network technology products will be created This will outfit your network with a powerful 1000 Mbps capable backb...

Страница 70: ...al power supply Acoustic Value DGS 1210 10P 0dB Fan less Operation Temperature 0 40 C Storage Temperature 10 70 C Operation Humidity 10 95 RH Storage Humidity 5 95 RH Emission EMI Certifications FCC c...

Страница 71: ...andling Bandwidth Control Security 802 1X port based access control Port Security IP and MAC ACL Broadcast Storm Control D Link Safeguard Engine Trusted Host Management Web based GUI or SmartConsole U...

Страница 72: ...of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should...