D-Link™
DGS-1005D
5-Port 10/100/1000Mbps
Gigabit Ethernet Switch
Manual
Second Edition
Building Networks for People
RECYCLABLE
6GS1005DML02
Страница 1: ...D Link DGS 1005D 5 Port 10 100 1000Mbps Gigabit Ethernet Switch Manual Second Edition Building Networks for People RECYCLABLE 6GS1005DML02 ...
Страница 2: ...adiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment thi...
Страница 3: ... 3 LED Indicators 3 REAR PANEL DESCRIPTION 5 INSTALLATION 6 Package Contents 6 BEFORE YOU CONNECT TO THE NETWORK 6 MOUNTING THE SWITCH ON A WALL 7 ATTACHING THE RUBBER FEET 7 PROVIDE FOR ADEQUATE VENTILATION 8 POWER ON 8 Power Failure 8 CONNECTING THE SWITCH 9 SWITCH TO END NODE 9 SWITCH TO HUB OR SWITCH 9 CONNECTING TO NETWORK BACKBONE OR SERVER 10 TECHNICAL SPECIFICATIONS 11 GLOSSARY 12 WARRANTY...
Страница 4: ...ub Switch or backbone server Appendix A Technical Specifications The technical specifications of the DGS 1005D Glossary Lists definitions for terms and acronyms used in this document Index Index of relevant terms in the DGS 1005D Manual Intended Readers The DGS 1005D Manual contains information for setup and management and of the DGS 1005D Switch This manual is intended for network managers famili...
Страница 5: ... you follow the operating instructions Keep your system away from radiators and heat sources Also do not block cooling vents Do not spill food or liquids on your system components and never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the openings of yo...
Страница 6: ...ollow your local national wiring rules When connecting or disconnecting power to hot pluggable power supplies if offered with your system observe the following guidelines Install the power supply before connecting the power cable to the power supply Unplug the power cable before removing the power supply If the system has multiple sources of power disconnect power from the system by unplugging all...
Страница 7: ...uthority or an electrician if you are uncertain that suitable grounding is available CAUTION The system chassis must be positively grounded to the rack cabinet frame Do not attempt to connect power to the system until grounding cables are connected Completed power and safety ground wiring must be inspected by a qualified electrical inspector An energy hazard will exist if the safety ground cable i...
Страница 8: ...s that frequently develop as computers and their busses get faster and more users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support video conferen...
Страница 9: ...tch is equipped with five ports providing dedicated 10 100 or 1000 Mbps bandwidth These ports can be used for connecting PCs printers servers routers Switches hubs and other network devices The five multi speed ports use standard twisted pair cabling and are ideal for segmenting networks into small connected subnets Each port can support up to 2000 Mbps of throughput in full duplex mode This stand...
Страница 10: ...r This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is connected to a station successfully and has a good link The indicator will blink to indicate that a port is transmitting or receiving data on the network Speed 1000Mbps Green 100Mbps Amber 10Mbps Off This indicator is amber colored when the port is connected to a ...
Страница 11: ...he five ports sequentially The initial port scan takes about 10 seconds If a cable fault is detected it is indicated by the corresponding port s Speed LED glowing amber for 5 seconds after the initial port scan The Switch is then reset for normal operation It takes about 2 seconds for the Switch to reset The entire Cable Diagnostic process takes about 17 seconds from the time the Switch is booted ...
Страница 12: ...C power adapter Check the technical specification section for information about the AC power input voltage Figure 1 3 Rear panel view of the Switch 10 100 1000BASE T Ports Five 5 Gigabit Ethernet Auto Negotiating ports 10 100 1000Mbps Comprehensive LED indicators display the conditions of the Switch and status of the network 5 ...
Страница 13: ...turdy level surface that can support at least 3 kg 6 6 lbs of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is adequate space for proper heat dissipation from and adequate ventilation around the Switch Leave at least 10 cm 4...
Страница 14: ...l 2 Drive the T3 x 15L screws into the Nylon screw anchors 3 Hook the mounting holes of the switch back on the screws you have completed the wall mount B Mounting on a wood wall 1 Drive the T3 x 15 L screws into the wood wall 2 Hook the mounting holes of the switch back on the screws you have completed the wall mount 1 3 4 inch minimum for wood wall 2 3 inch minimum for cement wall Figure 2 1 Moun...
Страница 15: ...t generates a significant amount of heat For the Switch to perform at its optimal level the Switch must have adequate ventilation to prevent the Switch from overheating and becoming damaged Power On Plug one end of the AC to DC power converter into the power connector of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will momentari...
Страница 16: ...y of the ports of the Switch Figure 3 1 Switch connected to an end node The Link Act LEDs for each UTP port light green when the link is valid The LED over the port label indicates a port speed of either 10 100 Mbps or 1000Mbps A blinking LED on the bottom indicates packet activity on that port Switch to Hub or Switch These connections can be accomplished in a number of ways using a standard Ether...
Страница 17: ... port on a hub or switch using either a straight or crossover cable any standard Ethernet cable is fine Connecting To Network Backbone or Server Any of the five Gigabit Ethernet ports are ideal for uplinking to a network backbone or network server Figure 3 3 Connection to a Server 10 ...
Страница 18: ...hield Twisted Pair UTP Cable Gigabit Ethernet 4 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Number of Ports Five 5 10 100 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs 5V 3A Power Consumption 11 watts maximum Operating Temperature 32 F 131F 0 C 55 Storage Temperature 14 F 158 F 10 C 70 C Humidity 5 95 RH non condensing Dimensions 9 25 in x 6 37 in x 1 4 in 235mm x 161 9...
Страница 19: ...s to a given MAC address each time a device is started In addition the protocol can assign the subnet mask and default gateway to a device bridge A device that interconnects local or remote networks no matter what higher level protocols are involved Bridges form a single logical network centralizing network administration broadcast A message sent to all destination devices on the network broadcast...
Страница 20: ...ld the other fail See also main port and standby port RJ 45 Standard 8 wire connectors for IEEE 802 3 10BASE T networks RMON Remote Monitoring Subset of SNMP MIB II which allows monitoring and management capabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a backup source of power when connected to the Switch server farm A cluster o...
Страница 21: ...ram to an application program on another device VLAN Virtual LAN A group of location and topology independent devices that communicate as if they are on a common physical LAN VLT Virtual LAN Trunk A Switch to Switch link which carries traffic for all the VLANs on each Switch VT100 A type of terminal which uses ASCII characters VT100 screens have a text based appearance 14 ...
Страница 22: ... magnetic media on which D Link delivers the Software will be free of physical defects D Link s sole obligation shall be to replace the non conforming Software or defective media with software that substantially conforms to D Link s functional specifications for the Software or to refund at D Link s sole discretion Except as otherwise agreed by D Link in writing the replacement Software is provide...
Страница 23: ...oducts or services provided by anyone other than D Link Products that have been purchased from inventory clearance or liquidation sales or other sales in which D Link the sellers or the liquidators expressly disclaim their warranty obligation pertaining to the product Repair by anyone other than D Link or an Authorized D Link Service Office will void this Warranty Disclaimer of Other Warranties EX...
Страница 24: ... a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee ...
Страница 25: ... oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Gerät ist gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 16 Bei Reparaturen dürfen nur Orginalersatzteile bzw den Orginalteilen entsprechende Teile verwendet werden Der Einsatz von ungeeigneten Ersatzteilen kann eine weitere Beschädigung hervorrufen 17 Wenden Sie sich m...
Страница 26: ...to Purchaser at Purchaser s expense and D Link reserves the right in such a case to levy a reasonable handling charge in addition mailing or shipping costs Software D Link warrants that its software products will perform in substantial conformance with the applicable product documentation provided by D Link with such software product for a period of ninety 90 days from the date of purchase from D ...
Страница 27: ... Gigabit Ethernet Switch Registration Register your product on line at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...
Страница 28: ...nology Tower No 11 Baishiqiao Road Haidan District 100081 Beijing China TEL 86 10 68467106 FAX 86 10 68467110 URL www dlink com cn E MAIL liweii digitalchina com cn Denmark D Link Denmark Naverland Denmark Naverland 2 DK 2600 Glostrup Copenhagen Denmark TEL 45 43 969040 FAX 45 43 424347 URL www dlink dk E MAIL info dlink dk Egypt D Link Middle East 7 Assem Ebn Sabet Street Heliopolis Cairo Egypt T...
Страница 29: ... 095 737 3389 7 095 737 3492 FAX 7 095 737 3390 URL www dlink ru E MAIL vl dlink ru Singapore D Link International 1 International Business Park 03 12 The Synergy Singapore 609917 TEL 6 6774 6233 FAX 6 6774 6322 E MAIL info dlink com sg URL www dlink intl com South Africa D Link South Africa Unit 2 Parkside 86 Oak Avenue Highveld Technopark Centurion Gauteng South Africa TEL 27 12 665 2165 FAX 27 ...
Страница 30: ...nited Kingdom TEL 44 020 8731 5555 SALES 44 020 8731 5550 FAX 44 020 8731 5511 SALES 44 020 8731 5551 BBS 44 0 181 235 5511 URL www dlink co uk E MAIL info dlink co uk U S A D Link U S A 17395 Mt Herrmann Fountain Valley CA 92708 4160 TEL 1 949 788 0805 FAX 1 949 753 7033 INFO 1 800 326 1688 URL www dlink com E MAIL tech dlink com support dlink com ...
Страница 31: ...____________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ ___________________...
Страница 32: ...__________________________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Banyan Vines DECnet Pathwork Windows NT Windows 2000 Windows XP Others_____________________________________________________________________________ 5 What network management program does your organization use D View HP...
Страница 33: ...D Link DGS 1005D Unmanaged Gigabit Ethernet Switch ...