D-D The Aquarium Solution DC750 Скачать руководство пользователя страница 7

Re f r i g e r a n t   C h i l l e r   M a n u a l

  

w w w.t h e a q u a r i u m s o l u t i o n .c o m 

7

OPERATION

Note:

 Before starting the chiller, you must run the pump to ensure the correct operation of the water circulating/

filtration system. 

There are three buttons for changing or setting the temperature on the control panel. (4 buttons on the  
DC4000 model)

AQUARIUM TEMPERATURE DISPLAY & SET TEMPERATURE DISPLAYS

When in operation, the display of the chiller will show the current water temperature. Press the (SET) button 
once and the display will change to show the current set temperature for the unit, a dot (1) on the display 
twinkles to indicate the setting temperature. Press the SET button once again or wait for 8 seconds and the 
display will return to the aquarium temperature. 

ADJUSTING THE SET TEMPERATURE

Press the (SET) button for more than three seconds to enter the programming mode, indicated by a beep 
and the current set temperature value will flash on the display. Press the   button for increasing temperature 
or   button for decreasing the temperature to set your new required parameters. You will hear a beep with 
each press whilst in programming mode. Press the (SET) button again to save or just wait for eight seconds. 
The display will revert to the temperature of the aquarium water whilst the chiller is working. The available 
temperature set range is from 4ºC to 28ºC.

DC4000 ONLY - ADJUSTING THE SET TEMPERATURE

There are 4 keys on the control panel for this larger model to control the cooling and additional heating cycle.

To adjust the chiller temperature, press (COLD) for 3 seconds and then follow the standard set temperature 
adjustment instructions above. Temperature adjustment is available between 3ºC to 46ºC

To adjust the heating temperature, press (HEAT) for 3 seconds and then follow the standard set temperature 
adjustment instructions above. Scroll through the modes with the 

arrows.

“TPS” will be shown on the display to indicate the heating temperature is enabled. Temperature adjustment is 
available between 3ºC to 46ºC.

“DST” will be shown on the display to indicate the temperature to start defrosting.

“DFT” will be shown on the display to indicate the temperature to stop defrosting.

Confirm the required mode by pressing (HEAT) again and the current set value will appear on the display, press 
the 

arrows to choose the required value and then press (HEAT) again to set or wait 8 seconds.

CHANGING DEFROST START AND STOP TEMPERATURES

The heating circuit of this chiller has a defrost function to maintain heating efficiency. This is not used on the 
cooling mode.

To change the START defrost temperature (default -3ºC), choose function DST from the above menu and press 
(HEAT) again to enable the setting mode. Press the 

arrows to choose the defrost start temperature (from 

-15ºC to +3ºC).

To change the STOP defrost temperature (d5C), choose function DFT from the above menu and press 
(HEAT) again to enable the setting mode. Press the 

arrows to choose the defrost stop temperature (from 

-12ºC to +15ºC).

ADJUST HYSTERESIS TEMPERATURE 

With the DC4000 model it is possible to adjust the hysteresis value between the on temperature and the off 
temperature between 1ºC and 3ºC. At 1ºC the chiller will switch off and off more often but maintain a tighter 
temperature range.

Press the 

key for 3 seconds until the digits twinkle and press the 

buttons to adjust the value.

EN

Содержание DC750

Страница 1: ...Refrigerant Chiller P R O D U C T U S E R M A N U A L For DC300 DC750 DC2200 DC4000...

Страница 2: ...TO SIMPLE PROBLEM SOLVING 10 WARRANTY 10 PARTS LIST 1 Front filter cover 2 Filter Front filter models only 3 Control panel 4 Front cover 5 Circuit board 6 Tank with evaporator 7 Seal sleeve 8 Filter s...

Страница 3: ...re titanium evaporator for both fresh salt water use 5 Over current protection device system 6 Temperature memory system automatically returning to the previously set temperature following a power fai...

Страница 4: ...000L 2000L Water Temperature After Refrigeration 18 C 18 C 16 C 16 C Water Volume Refrigerated Example B 300L 600L 2000L 4000L Water Temperature After Refrigeration 22 C 22 C 22 C 22 C 1 The rate of f...

Страница 5: ...e sources high temperature direct sunshine moisture or dust Fig 2 3 Place the unit on a horizontal stable surface Fig 3 4 Install at least 20 40cm away from any wall or structure for venting Fig 4 5 D...

Страница 6: ...s are in alignment with the grilles on the chiller and that the air outlet grille on the cabinet is made as high as possible to efficiently expel the hot air The chiller should be installed with its b...

Страница 7: ...llow the standard set temperature adjustment instructions above Temperature adjustment is available between 3 C to 46 C To adjust the heating temperature press HEAT for 3 seconds and then follow the s...

Страница 8: ...roller then the chiller will see this as a reset and delay for 3 minutes before starting the compressor AUTOMATIC ON OFF SWITCHING OF THE REFRIGERATION COMPRESSOR When the refrigeration compressor has...

Страница 9: ...dry soft cloth Fig 3 4 NEVER immerse the unit into water or flush it directly with water to prevent damage to the electric insulation of the chiller Fig 4 5 Disconnect the power supply plug if the uni...

Страница 10: ...not run and the display is dead Power not turned on Loose plug The fuse has blown Turn on the power Be sure the power cord is fully plugged in Change for a new fuse The chiller switches on and off Co...

Страница 11: ...FOLLOW US FOR INSPIRATION www theaquariumsolution com TheAquariumSoln fb com theaquariumsolution fb com groups theaquariumsolution...

Отзывы: