GUIDE TO SIMPLE PROBLEM SOLVING 

Before calling customer service, please check the following chart for possible causes to the problems you are 
experiencing. 

WARRANTY

1.   This product is warranted by us against defects due to faulty workmanship or materials. 
2.  If the product has been damaged under normal use it will be entitled to be repaired for free. Repairs under 

warranty are provided only upon production of proof of purchase if the date of the claim is within the 
guarantee period. 

3.  The warranty is not valid if the defect is due to accidental damage, misuse or neglect and in case of 

alterations or repair carried out by unauthorized personnel. 

SYMPTOM

CAUSE

SOLUTION

The chiller does not run and the display is 
dead.

Power not turned on

Loose plug

The fuse has blown

Turn on the power

Be sure the power cord is fully plugged in

Change for a new fuse

The chiller switches on and off

Connected to wrong voltage 
and/or frequency

Connect to correct power source, 
according to the name plate

Refrigeration capacity reduces or even no 
refrigeration

The chiller protection device is 
operating as normal

The setting temperature is 
higher than the aquarium water 
temperature

The air inlet and outlet are 
clogged with dirt

Loss of refrigerant medium

Too much water flow

Wait for 3 minutes and the chiller will turn 
on again automatically

Change the refrigeration temperature

Clean the dust from the air inlet and outlet 
with a brush or a vacuum cleaner

Refill the chiller with the correct 
refrigerant. Carried out by a qualified 
engineer.

Reduce water circulation

Runs noisy or with vibration

The base is not flat

Mount on a level surface

Содержание DC750

Страница 1: ...Refrigerant Chiller P R O D U C T U S E R M A N U A L For DC300 DC750 DC2200 DC4000...

Страница 2: ...TO SIMPLE PROBLEM SOLVING 10 WARRANTY 10 PARTS LIST 1 Front filter cover 2 Filter Front filter models only 3 Control panel 4 Front cover 5 Circuit board 6 Tank with evaporator 7 Seal sleeve 8 Filter s...

Страница 3: ...re titanium evaporator for both fresh salt water use 5 Over current protection device system 6 Temperature memory system automatically returning to the previously set temperature following a power fai...

Страница 4: ...000L 2000L Water Temperature After Refrigeration 18 C 18 C 16 C 16 C Water Volume Refrigerated Example B 300L 600L 2000L 4000L Water Temperature After Refrigeration 22 C 22 C 22 C 22 C 1 The rate of f...

Страница 5: ...e sources high temperature direct sunshine moisture or dust Fig 2 3 Place the unit on a horizontal stable surface Fig 3 4 Install at least 20 40cm away from any wall or structure for venting Fig 4 5 D...

Страница 6: ...s are in alignment with the grilles on the chiller and that the air outlet grille on the cabinet is made as high as possible to efficiently expel the hot air The chiller should be installed with its b...

Страница 7: ...llow the standard set temperature adjustment instructions above Temperature adjustment is available between 3 C to 46 C To adjust the heating temperature press HEAT for 3 seconds and then follow the s...

Страница 8: ...roller then the chiller will see this as a reset and delay for 3 minutes before starting the compressor AUTOMATIC ON OFF SWITCHING OF THE REFRIGERATION COMPRESSOR When the refrigeration compressor has...

Страница 9: ...dry soft cloth Fig 3 4 NEVER immerse the unit into water or flush it directly with water to prevent damage to the electric insulation of the chiller Fig 4 5 Disconnect the power supply plug if the uni...

Страница 10: ...not run and the display is dead Power not turned on Loose plug The fuse has blown Turn on the power Be sure the power cord is fully plugged in Change for a new fuse The chiller switches on and off Co...

Страница 11: ...FOLLOW US FOR INSPIRATION www theaquariumsolution com TheAquariumSoln fb com theaquariumsolution fb com groups theaquariumsolution...

Отзывы: