CZone 80-911-0007-00 Скачать руководство пользователя страница 14

EN / CZone® Output Interface (MOI) User & Installation Manual

 

14

 

 

         

  MODULE IDENTIFICATION LABEL 

These labels allow easy identification of each module whilst recording the dipswitch setting.  These labels are to be 

fitted to the cover and to the module (this prevents covers being swapped).  To record the module type and dipswitch 

settings use a permanent marker and strike through the applicable boxes (a strike through on a dipswitch box indicates 

that switch is on).  

 

  FIT THE COVER 

 

1.  Slide the cable gland up the output wires ensuring it is correctly seated. 

2.  Firmly push the top cover on to the MOI until you hear it click into pace on each side. 

3.  Ensure the cable gland is still correctly in place. 

4. 

Install circuit labels if you have purchased a label sheet.

 

WARNING!

  The MOI is only ignition protected with the cover correctly installed. 

 

  INITIAL POWER UP 

1.  Power up the NMEA2000 Network, system will flash all outputs for a short time while booting. 
2.  Check that the Network Status LED lights up. It may also be flashing if other devices are on the network and 

transmitting data. 

3.  Turn the switch/circuit breaker on supplying power to the input stud (if fitted). 
4.  Check the software version on the MOI with the CZone Configuration Tool and update if necessary. 
5.  Write the configuration file to the network (Refer to the CZone Configuration Tool Instructions for details on how 

to write a CZone configuration file). 

6.  Test all outputs for correctly configured functionality. 
7.  Check the circuit status LED’s for each individual circuit. Refer to LED codes to diagnose any faults which need 

to be rectified. 

 

XX

OI

SI

MI

SCI

MOI

DI

1 2

DIP

3 4 5 6 7 8

Fit The Cover 

Содержание 80-911-0007-00

Страница 1: ...Motor Output Interface MOI User Installation Manual V2 0...

Страница 2: ...cations of either its products or associated documentation Translations In the event that there is a difference between a translation of this manual and the English version the English version should...

Страница 3: ...nance And Repair 5 General Safety and Installation Precautions 5 3 OVERVIEW 6 Description 6 Features 6 MOI Hardware Overview 7 Led indicators 8 4 DESIGN 9 5 INSTALLATION 9 Things You Need 9 Environmen...

Страница 4: ...s chapter 2 of this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and spec...

Страница 5: ...the MOI in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the MOI other than mentioned in point 2 is not considered to be consistent with the inten...

Страница 6: ...cables of up to 16 mm2 6AWG in size or multiple smaller conductors No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone just a blade screwdriver A...

Страница 7: ...tput Circuit Fuses 12 Dipswitch 13 NMEA 2000 Connector 1 DC Power LED 2 Waterproof Cover 3 Circuit ID Labels 4 Protective Boot 5 Channel Status LEDs 6 Network Status LED 7 Module ID Label MOI HARDWARE...

Страница 8: ...dule Not Configured 2 Red Flash Configuration Conflict 3 Red Flash DIP Switch Conflict 4 Red Flash Memory Failure 5 Red Flash No Modules Detected 6 Red Flash Low Run Current 7 Red Flash Over Current 8...

Страница 9: ...f each connected load does not exceed maximum channel rating of 20A Install the appropriately rated fuses for each channel Loads exceeding 20A will require paralleling 2 channels together 5 INSTALLATI...

Страница 10: ...cable grommet for wiring bend radius o Note Cable radius determined by wiring manufacturer 3 Fasten the MOI by using 4 x 8G or 10G 4mm or 5mm self tapping screws or bolts not supplied IMPORTANT The M...

Страница 11: ...utput wires through cable grommet 2 Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4 43 in lbs 0 5NM 3 Insert plug firmly i...

Страница 12: ...MAL bottom position of all circuits 3 The ATC fuse should be rated to protect the connected load and the wiring from the MOI to the load and also the ground wire MECHANICAL BYPASS The MOI includes a m...

Страница 13: ...ve advanced functionality such as timers load shedding or one touch Modes of operation a custom configuration needs to be installed Set the dipswitch on the MOI to match the configuration file All oth...

Страница 14: ...e purchased a label sheet WARNING The MOI is only ignition protected with the cover correctly installed INITIAL POWER UP 1 Power up the NMEA2000 Network system will flash all outputs for a short time...

Страница 15: ...SYSTEM DIAGRAM EXAMPLES System Diagram BILGE PUMP BATTERY HATCH LIFTER NMEA 2000 NETWORK DC Negative Input DC Positive Input Reversible output pair CIRCUIT BREAKER Positive DC Output 1 Positive DC Out...

Страница 16: ...0 5 6mm 24AWG 8AWG Output channels 1x 20A H Bridge channel 12 24 2 x 20A Output channels 12 24V Maximum current 60A Total Module Current Dimming Output channels PWM 100Hz Power supply M6 1 4 Positive...

Страница 17: ...ssenger cars and light commercial vehicles with nominal 12 V supply voltage Electrical transient conduction along supply lines only ISO 7637 2 24V Commercial vehicles with nominal 24 V supply voltage...

Страница 18: ...EN CZone Output Interface MOI User Installation Manual 18 8 Declaration of Conformity...

Отзывы: