EN / CZone® Meter Interface (MI) User & Installation Manual

 

 

          

2  GENERAL INFORMATION 

  USE OF THIS MANUAL   

Copyright © 2019 BEP Marine. All rights reserved.

Reproduction, transfer, distribution, or storage of part or all of the 

contents in this document in any form without the prior written permission of BEP Marine is prohibited.

This manual 

serves as a guideline for the safe and effective operation, maintenance and possible correction of minor malfunctions 
of the Meter Interface Module (MI)

.

 

This manual is valid for th

e following: 

 

Description  

Part number  

CZONE METER INTERFACE c/w SEAL & PLUG 

80-911-0005-00 

CZONE METER INTERFACE NO SEAL & PLUG 

80-911-0006-00 

 

It is obligatory that every person who works on or with the Meter Interface is completely familiar with the contents of this 
manual, and that he/she carefully follows the instructions contained herein.

 

Installation of, and work on the Meter Interface, may be carried out only by qualified, authorized, and trained personnel, 

consistent with the locally applicable standards and taking into consideration the safety guidelines and measures. Please 

keep this manual in a secure place!

  

  GUARANTEE SPECIFICATIONS 

BEP Marine guarantees that this unit has been built according to the legally applicable standards and specifications. 
Should work take place which is not in accordance with the guidelines, instructions and specifications contained in this 
Installation manual, then damage may occur and/or the unit may not fulfil its specifications. All these matters may mean 
that the guarantee becomes invalid. 

 

  QUALITY 

During their production and prior to their delivery, all our units are extensively tested and inspected. The standard 
guarantee period is two years. 

 

  VALIDITY OF THIS MANUAL 

All the specifications, provisions and instructions contained in this manual apply solely to standard versions of the Meter 
Interface (MI)

 

delivered by BEP Marine. 

 

  LIABILITY 

BEP can accept no liability for: 

 

  Consequential damage due to use of the Meter Interface.  Possible errors in the manuals and the results thereof. 

 

CAREFUL! 

Never remove the identification label 

 

 

Important technical information required for service and maintenance can be derived from the type number plate.  

  CHANGES TO THE METER INTERFACE (MI) 

Changes to the Meter Interface may be carried out only after obtaining the written permission of BEP.  

Содержание 80-911-0005-00

Страница 1: ...Meter Interface MI User Installation Manual V2 0...

Страница 2: ...Measures 4 Maintenance And Repair 4 General Safety and Installation Precautions 4 4 OVERVIEW 5 Description 5 Features 5 Component Overview 5 5 INSTALLATION 6 Guidelines 6 DC Connections 6 AC Connectio...

Страница 3: ...es and measures Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and specifications...

Страница 4: ...Meter Interface in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Meter Interface other than mentioned in point 2 is not considered to be cons...

Страница 5: ...ES AC 3 x AC voltage inputs multi voltage 2 x AC current inputs Calculates true RMS power DC 3 x DC voltage inputs multi voltage 2 x DC current inputs Calculates battery capacity as Ampere hours and p...

Страница 6: ...each input is fused at supply with a 1A fuse Voltage Input 3 is a voltage meter only Connect the current input from each shunt Ensure care is taken when wiring shunt into heavy DC system to make sure...

Страница 7: ...nput 1 from transformer AC Current input 1 from transformer Note these are paired inputs for correct metering these must be matched to the same supply source matched to the same supply source for corr...

Страница 8: ...es are present and transmitting data 4 Check that the Power indicator LED is green 5 Check the circuit s status LEDs for each individual circuit Refer to LED codes to diagnose any faults which need to...

Страница 9: ...h Channel Not Configured 2x Red Flash Configuration Conflict 3x Red Flash Dip Switch Conflict 4x Red Flash Memory Comms Failure 5x Red Flash No Modules Detected 8x Red Flash Invalid Input Signal 2 Net...

Страница 10: ...hese labels are to be fitted to the cover and to the module this prevents covers being swapped To record the module type and dipswitch settings use a permanent marker and strike through the applicable...

Страница 11: ...A 2000 NETWORK Transformer common AC Voltage input 3 from transformer AC Voltage input 2 from transformer AC Current input 2 from transformer AC Voltage input 1 from transformer AC Current input 1 fro...

Страница 12: ...H SWITCH BATTERY 1AMP FUSE 1AMP FUSE 450A 50mV SHUNT PUMP BILGE HORN WIPER BUS BAR BUS BAR NEGATIVE TWISTED PAIR OUTPUT INTERFACE TWO BATTERY ENGINE ALT 1 ALT 2 8 Way DC DC Negative DC voltage positiv...

Страница 13: ...13 EN CZone Meter Interface MI User Installation Manual 10 Dimensions Figure 9 Dimensions...

Страница 14: ...11 0042 00 TERM BLOCK MI 8 WAY PLUG 5mm PITCH 80 911 0043 00 DC CURRENT SHUNT 450A LB 450 50 CURRENT TRANSFORMER AC DIGITAL METER CT 10 3 AC VOLT TRANSDUCER FOR DIG CZONE MC12 AC VSEN 4 12 EMC ratings...

Страница 15: ...15 EN CZone Meter Interface MI User Installation Manual 13 Declaration Of Conformity...

Отзывы: