This manual provides brief instructions for installing and connecting the CP9000 Comfort

Controller. Please download the supplementary Installation Manual and programming guides

from

http://www.cytech.biz/installation_and_programming.html

Please read this Quick Installation and Supplementary Installation manuals before installing

Comfort

Introduction to the Comfort PCB

Please refer to the Hookup Diagram on the Lid of the Comfort Enclosure

Comfort PCB

LED Indicators

D1 (Red) LED - If Steady, system is armed. If Flashing, system is in Alert or Alarm state.

D2 Green) LED - If Steady, system is disarmed. If Flashing, system is in Trouble State.

U4 File System Mismatch

On

On

U1 Fault, No Power, or UCM Programming cable is connected

Off

Off

Alarm, Disarmed

On

Flash

Alert/Alarm, Trouble

Flash

Flash

Alarm, Armed

Off

Flash

Armed, Trouble

Flash

On

Armed, Normal

Off

On

Disarmed, Trouble

Flash

Off

Disarmed, Normal

On

Off

STATUS

GREEN (D2)

RED (D1)

Connections - Analog Section (Right Half)

AC (JP51) - Connected to Transformer secondary 14VAC (NOT Mains Voltage)

BATT (JP52) - Connected to 12V 7AH Sealed Lead-Acid Battery via supplied Battery cable.

TEL IN (MJ51) - Connection to Telephone Line

TEL OUT (MJ52) - Connection to House phones.

KP MIC/VOICE (JP53) - connection to Keypads MIC/VOICE

DP MIC/VOICE (JP54) - connection to Door Stations MIC/VOICE

GSM (J54) - connection to UCM/GSM Module audio signals.

RGR (J57) - Ringer Board RGR05 mounting

Comfort II Quick Installation Guide

Page 1 of 12

Содержание CP9000 Comfort II

Страница 1: ...n Trouble State U4 File System Mismatch On On U1 Fault No Power or UCM Programming cable is connected Off Off Alarm Disarmed On Flash Alert Alarm Trouble Flash Flash Alarm Armed Off Flash Armed Troubl...

Страница 2: ...nce only using 4 way cable WA485 Shunts Settings Digital Section Left Half ID J3 DO NOT SHUNT SRNTMP J4 Leave this Shunted JZ1 JZ8 3x8 way header EOL Shunts Insert shunt in the position nearest the te...

Страница 3: ...other wiring is completed Backup Battery JP2 Connect a 12V 7 AH sealed lead acid battery to the BATT JP2 terminals using the supplied Battery Cable This will give more than 24 hours of standby power t...

Страница 4: ...per switches Alternately the Siren Bellbox tamper terminals can be connected to a spare zone input on Comfort which is programmed as a Tamper Zone Type Tamp Com SRN SRN STR 12VF SPK 12V 0V TRIG TRIG T...

Страница 5: ...filter must be connected between the ADSL modem and Comfort Comfort is connected to the Telephone end of the micro filter It will not necessary to use micro filters for the other telephones in the ho...

Страница 6: ...Phone System Incoming Telephone Line CO 1 Control Phone Fax Connection before PABX Keyphone System Connection to extension of PABX It is also possible to connect the system as an analogue extension o...

Страница 7: ...ne Settings in the Engineer menu determine if the contact is Normally Closed N C or Normally Open N O N O and N C contacts cannot be connected on a single zone To provide a global tamper protection fo...

Страница 8: ...dicating Fire Evacuation is produced when this zone type is activated by default If the zone wiring is cut or open circuit or shorted a Zone Trouble alarm is generated S12V COM 12V IN OUT N O Contact...

Страница 9: ...ould not exceed 500 mA and protected by a resettable fuse F2 If higher current is required an external supply may be used instead of the 12V terminals Connection to Relays Connect 12V relays to output...

Страница 10: ...9000 using the supplied white 4 way cable or by CAT5 cable to terminal blocks 12V COM KA KB for longer distances Set Each UCM to a unique ID from 1 to 8 via the SW7 ID shunts The UCM Manuals can be do...

Страница 11: ...in board or Local Expansion Module LEM and label accordingly Connect detector 12V supplies to the auxiliary 12V output terminal block 14 Check all zone jumpers are in the double EOL 1 2 away from term...

Страница 12: ...nt version Please check and download the latest version from http www cytech biz manuals html Comfort II Quick Installation Guide Page 12 of 12 Copyright Cytech Technology Pte Ltd RCB 199506853M Title...

Отзывы: