Getting Started with EZ-BT WICED Modules
Document Number: 002-23400 Rev. **
108
C . 5 . 4 Ad d i t i o n a l S w i t c h e s a n d L E D s
▪
SW1 (RESET switch): SW1 is a tactile switch that is connected directly to the XRES connection of the CYBT-
483039-02 module. Activating this switch will reset the EZ-BT WICED Module. This switch is also used in the
process of (re-)programming the CYBT-483039-02 module on the evaluation board.
▪
SW2 (RECOVER switch): SW2 is provided to recover a module that has the standard programming bootloader
and/or application image corrupted or erased. Recovery mode is activated by holding this button down while
pressing and releasing SW1 (RESET). Recovery mode is used prior to programming the module with a new binary
image.
▪
SW3 (USER switch): SW3 is provided as an element that the user can configure as required. The SW3 element
is connected to P1 on the CYBT-483039-02 module (solder pad 9). Header J9 is provided on the CYBT-483039-
EVAL board to disconnect P1 from the USER switch to allow this connection to be used on the Arduino Headers
without SW3 connected.
▪
D1 USER LED is provided for user-configured behavior as required. The D1 LED is connected to the module P26
connection (solder pad 6). Header J10 is provided on the CYBT-483039-EVAL board to disconnect P26 from the
USER LED to allow this connection to be used on the Arduino Headers without D1 connected.
▪
D2 and D3 LEDs are provided to display programming or USB activity while in progress.
▪
D7 LED is provided to show that power is provided from the host PC.
C . 5 . 5 P r o g r a m m i n g o r R e p r o g r a m m i n g t h e C Y B T - 4 8 3 0 3 9 - E V AL B o a r d
Refer to Section
for general information on how to program or reprogram EZ-BT WICED Modules. You may also
refer to
To program an EZ-BT WICED module in your own manufacturing line, you must ensure that both the Recover and
Reset connections on the EZ-BT module are exposed in order to put the module into programming/recovery mode.