background image

Document Number: 002-09764 Rev. *G 

Page 11 of 39

CYBLE-212019-00
CYBLE-212023-10

Figure 8.  Recommended Host Schematic for an Independent Supply Option

Two Ferrite Bead Option (Seen from Bottom)

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание EZ-BLE PRoC CYBLE-2120 0 Series

Страница 1: ...to 85 C 32 bit processor 0 9 DMIPS MHz with single cycle 32 bit multiply operating at up to 48 MHz Watchdog timer with dedicated internal low speed oscillator ILO Two pin SWD for programming Power Con...

Страница 2: ...enables concurrent hardware and firmware editing compiling and debugging of PSoC 3 PSoC 4 PSoC 5LP PSoC 4 BLE PRoC BLE and EZ BLE module systems with no code size limitations PSoC peripherals are des...

Страница 3: ...em Resources 23 Environmental Specifications 29 Environmental Compliance 29 RF Certification 29 Safety Certification 29 Environmental Conditions 29 ESD and EMI Protection 29 Regulatory Information 30...

Страница 4: ...cal drawings in Figure 1 All dimensions are in millimeters mm Table 1 Module Design Dimensions See Figure 1 on page 5 for the mechanical reference drawing for CYBLE 2120XX X0 Dimension Item Specificat...

Страница 5: ...Note 1 No metal should be located beneath or above the antenna area Only bare PCB material should be located beneath the antenna area For more information on recommended host PCB layout see Figure 3...

Страница 6: ...t area stated in item 2 Refer to AN96841 for module placement best practices 2 To maximize RF performance the area immediately around the Cypress BLE module trace antenna should contain an additional...

Страница 7: ...er side shown in Figure 6 is the minimum recommended host pad length The host PCB layout pattern can be completed using either Figure 4 Figure 5 or Figure 6 It is not necessary to use all figures to c...

Страница 8: ...13 10 0 39 16 31 15 35 642 13 11 0 39 17 58 15 35 692 13 12 2 04 18 82 80 31 740 94 13 3 31 18 82 130 31 740 94 14 4 58 18 82 180 31 740 94 15 5 85 18 82 230 31 740 94 16 7 12 18 82 280 31 740 94 17 8...

Страница 9: ..._TX SCB0_MISO SCB0_SCL TCPWM Sensor 23 P0 7 SCB0_CTS SCB0_SCLK TCPWM Sensor SWDCLK 24 P0 6 SCB0_RTS SCB0_SS0 TCPWM Sensor SWDIO 25 GND 5 Ground Connection 26 GND 5 Ground Connection 27 GND 5 Ground Co...

Страница 10: ...DD and VDDR separately External Component Recommendation In either connection scenario it is recommended to place an external ferrite bead between the supply and the module connection The ferrite bead...

Страница 11: ...ly Option Two Ferrite Bead Option Seen from Bottom Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arr...

Страница 12: ...E 2120XX X0 Schematic Diagram Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Страница 13: ...cription Silicon U1 56 pin QFN Programmable Radio on Chip PRoC with BLE Crystal Y1 24 000 MHz 12PF Crystal Y2 32 768 kHz 12 5PF Item Description Frequency Range 2400 2500 MHz Peak Gain 0 5 dBi typical...

Страница 14: ...jected per pin LU Pin current for latch up 200 200 mA Parameter Description Min Typ Max Units Details Conditions RFO RF output power on ANT 18 0 3 dBm Configurable via register settings RXS RF receive...

Страница 15: ...3 V IDD28 GPIO and reset active nA T 40 C to 85 C Hibernate Mode VDD 3 6 V to 5 5 V IDD29 GPIO and reset active nA T 25 C VDD 5 V IDD30 GPIO and reset active nA T 40 C to 85 C Stop Mode VDD 1 8 V to...

Страница 16: ...IGH level VDD 0 5 V IOH 1 mA at 1 8 V VDD VOL Output voltage LOW level 0 6 V IOL 8 mA at 3 3 V VDD Output voltage LOW level 0 6 V IOL 4 mA at 1 8 V VDD Output voltage LOW level 0 4 V IOL 3 mA at 3 3 V...

Страница 17: ...RISE_OVFS Output rise time in Fast Strong mode 1 5 12 ns 25 pF load 10 90 VDD 3 3 V TFALL_OVFS Output fall time in Fast Strong mode 1 5 12 ns 25 pF load 10 90 VDD 3 3 V TRISESS Output rise time in Slo...

Страница 18: ...es are being used for other functionality then the maximum number of differential ADC channels is three Table 19 SAR ADC AC Specifications Parameter Description Min Typ Max Units Details Conditions A_...

Страница 19: ...e 5 Ratio Capacitance range of 9 pF to 35 pF 0 1 pF sensitivity Radio is not operating during the scan IDAC1_CRT1 Output current of IDAC1 8 bits in High range 612 A IDAC1_CRT2 Output current of IDAC1...

Страница 20: ...nt consumption at 3 MHz 42 A 16 bit counter ICTR2 Block current consumption at 12 MHz 130 A 16 bit counter ICTR3 Block current consumption at 48 MHz 535 A 16 bit counter Table 23 Counter AC Specificat...

Страница 21: ...DC Specifications Parameter Description Min Typ Max Units Details Conditions ILCDLOW Operating current in low power mode 17 5 A 16 4 small segment display at 50 Hz CLCDCAP LCD capacitance per segment...

Страница 22: ...ns FSPI SPI operating frequency master 6x over sampling 8 MHz Table 34 Fixed SPI Master Mode AC Specifications Parameter Description Min Typ Max Units Details Conditions TDMO MOSI valid after SCLK dri...

Страница 23: ...Max Units Details Conditions TPPOR_TR Precision power on reset PPOR response time in Active and Sleep modes 1 s Table 40 Brown Out Detect Parameter Description Min Typ Max Units Details Conditions VFA...

Страница 24: ...D Block current 100 A Table 43 Voltage Monitor AC Specifications Parameter Description Min Typ Max Units Details Conditions TMONTRIP Voltage monitor trip time 1 s Table 44 SWD Interface Specifications...

Страница 25: ...needs to be loaded to register CY_SYS_XTAL_BLERD_BB_XO_CAPTRIM_REG Table 50 BLE Subsystem Parameter Description Min Typ Max Units Details Conditions RF Receiver Specification RXS IDLE RX sensitivity...

Страница 26: ...BLE third fourth and fifth offset channel 50 dBm RF PHY Specification RCV LE CA 05 C RXSE1 Receiver spurious emission 30 MHz to 1 0 GHz 57 dBm 100 kHz measurement bandwidth ETSI EN300 328 V1 8 1 RXSE2...

Страница 27: ...y design simulation ITX 3dBm TX current at 3 dBm setting PA4 15 5 mA ITX 6dBm TX current at 6 dBm setting PA3 14 5 mA ITX 12dBm TX current at 12 dBm setting PA2 13 2 mA ITX 18dBm TX current at 18 dBm...

Страница 28: ...ow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded...

Страница 29: ...ayer to provide ESD protection and a low impedance path to ground Device Handling Proper ESD protocol must be followed in manufacturing to ensure component reliability Description Minimum Specificatio...

Страница 30: ...roduct as well as the FCC Notice above The FCC identifier is FCC ID WAP2011 In any case the end product must be labeled exterior with Contains FCC ID WAP2011 ANTENNA WARNING This device is tested with...

Страница 31: ...ppareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement LABELING REQUIREMENTS The Original Equipment Manufacturer OEM must...

Страница 32: ...om Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downl...

Страница 33: ...kage MSL CYBLE 2120XX X0 31 pad SMT MSL 3 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Do...

Страница 34: ...rom Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Down...

Страница 35: ...y Maximum Reel Quantity Comments Reel Quantity 500 500 Ships in 500 unit reel quantities Minimum Order Quantity MOQ 500 Order Increment OI 500 U S Cypress Headquarters Address 198 Champion Court San J...

Страница 36: ...Table 57 Units of Measure Symbol Unit of Measure C degree Celsius kV kilovolt mA milliamperes mm millimeters mV millivolt A microamperes m micrometers MHz megahertz GHz gigahertz V volt Downloaded fr...

Страница 37: ...and maximum reel quantities ship for orders of the CYBLE 2120XX X0 module Updated to new template D 5529621 DSO 11 15 2016 Updated More Information Added EZ Serial BLE Firmware Platform section Updat...

Страница 38: ...Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Ar...

Страница 39: ...as critical components in systems designed or intended for the operation of weapons weapons systems nuclear installations life support devices or systems other medical devices or systems including re...