3.5 SmartSense_EMCPLUS User Module Parameters
Figure 3-12. PSoC Designer SmartSense_EMCPLUS Parameters
3.5.1.1 Immunity Level
This parameter defines the immunity level of the user module against the external noise. Selecting a High immunity
level provides maximum immunity against the external noise. A Medium immunity level provides moderate immunity.
Setting the immunity level to Medium consumes twice the scan time and RAM memory, and setting the immunity
level to High consumes three times the scan time and RAM memory for sensor implementation compared to the Low
immunity mode.
Possible values are Low, Medium, and High.
Figure 3-13. PSoC Designer SmartSense_EMCPLUS Global Setting
3.5.1.2 Threshold Setting Mode
Selecting the Manual threshold mode provides flexibility in setting the finger threshold for each sensor. Selecting
Automatic threshold mode causes the SmartSense_EMCPLUS user module to automatically set the thresholds for
each sensor. Automatic threshold mode consumes more RAM than Manual threshold mode.
Possible values are Manual and Automatic.
High Level
Low Level