3.1.1.1 Getting Started with CapSense User Modules
To create a new CY8C20xx7/S project in PSoC Designer:
1. Create a new PSoC Designer project with CY8C20xx7/S as the target device.
2. Select and place the CSDPLUS/SmartSense_EMCPLUS User Module.
3. Right-click the user module to access the User Module wizard.
4. Set button sensor count, slider configuration, pin assignments, and associations.
5. Set pins and global user module parameters.
6. Generate the application and switch to the Application Editor.
7. Adapt sample code from the user module datasheet to implement buttons or sliders.
For a detailed procedure for creating a PSoC Designer project and configuring the User Module wizard, refer to the
datasheet of the specific user module. For code examples on CapSense user modules, see
3.1.2 CY8C20xx7/S QuietZone Starter Kit
The CY8C20xx7/S QuietZone Starter Kit features simple plug-in hardware to make prototyping easy. The kit is
available from our module partner ArtaFlex at the following link:
www.artaflexmodules.com/quietzone
Figure 3-2. CY8C20xx7/S QuietZone Starter Kit
3.1.3 CapSense Data Viewing Tools
Many times during CapSense design, you will want to monitor CapSense data (raw counts, baseline, difference
counts, and so on) for tuning and debugging purposes. There are two CapSense data viewing tools, MultiChart and
Bridge Control Panel. These tools are explained in the application note
.