1. Insert the kit CD in the CD drive.
2. Install kit content, PSoC Designer, PSoC
Programmer, and Bridge Control Panel.
Note
The hardware prerequisites for this kit are
the CY3280-20x34 Universal CapSense
Controller (UCC) board and MiniProg1.
1. Connect the CY3280-BSM board to the
CY3280-20x34 UCC board’s P2 connector.
2. In the CY3280-20x34 board, place the
jumper on header J1 to short pins 2 and 3. In
the CY3280-BSM board, place the jumper on
header J2 to short pins 2 and 3.
3.
Connect MiniProg1 to the CY3280-
20x34 UCC board’s ISSP connector (J3).
Connect it to your PC using a USB cable.
1. Open PSoC Programmer and click
File > File Load. Browse and load the
CY3280_BSM_20x34.hex
file.
2. Click the Connect button.
3. Click the Program button to program the
device.
4. Click the Toggle power button to power
the board.
Note
The hex file is located at:
<Install directory>\Cypress\CY3280
BSM\<version>\Firmware\20x34_CSA\
CY3280_BSM_20x34\CY3280_BSM_20x34\
1. When you touch a button, the
corresponding LED on the module board
lights up, indicating the button you
touched.
2. Next, touch the same buttons to turn
off the LED. You can touch multiple
buttons at the same time.
1
2
3