Power Outlet
(KVM Ports > Active > Server Name > Power Outlet)
The Power Outlet window allows you to assign the AlterPath PM outlet
number(s) that powers the current port.
1. Enter
the AlterPath PM outlet number that powers the selected
computer, otherwise leave the field box blank.
If you are using two
outlets, use a space to separate the second outlet (
e.g
., 4 16).
2. Tab to the
Save
button and press <Enter> to complete the procedure.
To complete the configuration required to establish a power control
session, you need to configure the AUX serial port of your KVM unit for
the power management profile. You can do this through the web
interface using the following procedure:
1.
Log on to the AlterPath KVM through the web interface as shown in
Chapter 5: KVM Operation.
2.
From the menu to the left of the Configuration screen, select Serial
Ports.
You will see the screen for configuring the ttyS1 port, which is the
AUX serial port of your KVM.
3.
Select AlterPath PM Profile.
4.
Save the configuration, making sure that you select serial ports
configuration.
Configuring a Server Connected to a Slave
When configuring a server that is connected to a slave KVM, follow the same
procedure described for configuring servers. You choose a server that is
connected to a slaved KVM. In response, the system will bring you the
Physical Port window, with the currently configured physical port selected
Содержание AlterPath KVM 16
Страница 10: ...Table of Contents VIII AlterPath KVM Manual This page has been intentionally left blank...
Страница 14: ...Before You Begin iv AlterPath KVM Manual This page has been intentionally left blank...
Страница 22: ...1 Introduction 1 8 AlterPath KVM Manual This page has been intentionally left blank...
Страница 92: ...3 KVM OSD Configuration 3 58 AlterPath KVM Manual This page has been intentionally left blank...
Страница 196: ...Appendix A TechnicalSpecifications A 4 AlterPath KVM Manual This page has been intentionally left blank...