CyboInverter H Model Q & A - 1
Yes. You have to disconnect the grid AC from
the heater. Otherwise, the grid AC can damage
the CyboInverter.
Can I use the H model for
single-element electric
water heaters?
1
You should add a thermostat. This will allow
you to switch off the grid power. Contact us for
more detailed suggestions.
My heater has 2 elements
but only 1 thermostat. What
can I do?
2
The following settings are examples:
Upper Thermostat = 98-100ºF (37-38 ºC)
Lower Thermostat = 135-140ºF (57-60ºC)
Hot water circulates upwards so the Upper
Element does not turn on if temp is higher than
the setpoint, resulting in electricity savings.
How do I set the temp
setpoints for the upper and
lower thermostat?
3
Yes. Just make sure the inverter output and
grid AC are not connected.
Can I use this for tankless
electric water heaters?
4
Question
Answer
No