2.2.3 Portrait
Orientation
Note
: Follow Rack-Mount Gasket Installation procedure (if necessary) prior to beginning
the steps below.
1.
Align mounting plate rack-mount holes with server rack mounting holes; see
Figure 4 for correct mounting orientation.
Ensure gasket faces outward
.
2.
Install the eight 10-32 1/2
″
button head bolts into rack-mounting holes to secure
mounting plate to the server rack.
Note
: Steps 3 & 4 require two people.
3.
Align studs with the monitor mounting holes in mounting plate and install the
C
Y
RAQ
TM
until the gasket is flush with rear of enclosure.
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4.
From inside rack, a second person must install and tighten the fourteen 10-32
mounting nuts.
Figure 4: Rack-Mount Portrait Installation
CyberResearch, Inc
.
15
25 Business Park Drive
P: (203) 483-8815; F: (203) 483-9024
Branford, CT USA
www.cyberresearch.com