background image

 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Value600EI/800EI/1000EI   

User

’s Manual 

K01-C000056-00 

 

SAFETY WARNINGS   

(SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 
install, or operate your UPS. 
 
This equipment can be operated by any individuals with no previous training. 
 
The socket-outlet shall be installed near the equipment and easily accessible. 
 
During the installation of this equipment it should be assured that the sum of the leakage currents of the 
UPS and the connected loads does not exceed 3.5mA. 
 
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, 
hazardous voltage still may be accessible through supply from battery. The battery supply should be 
therefore disconnected in the plus and minus pole at the quick connectors of the battery when 
maintenance or service work inside the UPS is necessary. 
 
Do not dispose of batteries in a fire, the battery may explode. 
 
Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes. 

 

 

INSTALLING YOUR UPS SYSTEM   

 
UNPACKING 

 
Inspect the UPS upon receipt. The box should contain the following: 

(1)UPS Unit

1; (2)IEC Power Cord

×

2; (3)USB Cable

1; (4)User Manual

1; (5)Management software 

Disk

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1.  Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS 

unit’s rated capacity ( 600VA/360W for Value 600EI, 800VA/480W for Value 800EI, 1000VA/550W for 
Value 1000EI). If rated unit capacities are exceeded, an overload condition may occur and cause the 
UPS unit to shut down or the fuse blow. 

 
2.  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert 

Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only 
calculates the maximum amount of VA that the equipment can use, not what is typically used by the 
equipment at any one time. Users should expect usage requirements to be approximately 60% of 
below value. 

 
TO ESTIMATE POWER REQUIREMENTS 

 
1.              Amps (A) x 230 =                VA 
 
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual 

requirements. There are many factors that can affect the amount of power that your computer system 
will require. The total load that you will be placing on the battery-powered outlets should not exceed 
80% of the unit’s capacity. 

 

HARDWARE INSTALLATION GUIDE 

 
Before installation, please read and understand the following instructions: 

1. 

Placement 

The UPS must be installed in a protected environment away from heat- emitting appliances such 
as a radiator or heat register. Do not install this product where excessive moisture is present. 

 

 

 

2. 

Ventilation 

The location should provide adequate air flow around the UPS with one inch minimum clearance 
on all sides for proper ventilation. 

 

3. 

Charge the Battery 

Your new UPS may be used immediately upon receipt. However charge loss may occur during 
shipping and storage. So charging the battery for at least 8 hours is recommended to insure that 
the battery is fully charged. (To recharge the battery, simply leave the unit plugged into an AC 
outlet.)   

This UPS can be charged even when UPS is not turn on

.

 

 

4. 

Connect to AC 

To connect the UPS to a wall outlet. 
Please avoid using extension cords   
and adapter plugs. (To maintain   
optimal battery charge, leave the   
UPS plugged in at all times.)   

 

 

5. 

Connect the Load 

Connect the equipment to your UPS 
outlets. 

Items such as copiers, laser   

printers, vacuums, space heaters,   
or other large electrical devices   
SHOULD NOT be connected to the   
UPS.

 Please make sure that the total 

loads of your equipments are less than the maximum total power load of your UPS. 

 

6. 

Connect to Computer: 

Install your software and accessories. To use the software, simply use the enclosed serial interface 
or USB cable to connect the UPS unit and your computer. 

   

     

   

 

BASIC OPERATION 

 

FRONT PANEL DESCRIPTION 

 
 
 
 

 

 

 

 

 

 
 

 

 

 

 

1. 

Power On Indicator 

 

This LED is illuminated when the utility condition is normal and the UPS outlets are providing “clean 
power”, free of surges and spikes. 

2. 

Power Switch 

 

Press the power switch to turn the UPS ON or OFF. 

 
 

REAR PANEL DESCRIPTION 

 

 
 
 
 
 
 
 
 
 
 

 

 

1. 

AC Inlet

   

Connect to utility power through the input power cord 

 
2. 

Input Fuse 

The fuse provides optimal overload protection.

 

 
3. 

AC outlet 

The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation 
during a power failure and against surges and spikes. 

 
4. 

Serial Port to PC 

This port allows connection and

   

communicates from the DB-9 serial   
on the computer to the UPS unit.   
The UPS communicates its status   
to the PowerPanel

®

 software. This   

interface is also compatible with the   
UPS service provided by 

Windows 8/7 

/Vista/XP/2000/Server 2003/2008/2012 
Mac OSX, Linux. 
 

                                                                                           

Отзывы: