Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at 

www.cyberpower.com

. Registration certifies your product's warranty, confirms your ownership in the event of a 

product loss or theft and entitles you to free technical support. Register your product now to receive the benefits of 
CyberPower ownership. 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation 

and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free 

of conductive contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is 

disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into 

an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a 

computer component. 

CAUTION!

    To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over 

current protection in accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer / Data 

Processing Equipment, ANSI/NFPA 75. 

CAUTION!

    Risk of explosion if battery is replaced by an incorrect type. Batteries shall be installed by service 

personnel, and the replacement of batteries with a suitable recommended type. Dispose of used batteries according to 

the instructions. 

CAUTION!

    Do not dispose of batteries in a fire. The batteries may explode. 

CAUTION!

    Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!   

CyberPower Systems does not sell products for life 

support or medical applications. 

DO NOT

 use in any circumstance that would affect operation and safety of life support 

equipment, any medical applications or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an 

aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit 

on any transportation such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp 

environment can cause the unit to short out.

 

 
 
 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following:

   

(a) UPS unit (b) User’s manual (c) Warranty registration card. 

 

SYSTEM FUNCTION BLOCK DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

1.  Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (350VA/255W for 

CP350SLG). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit 

to shut down or the circuit breaker to trip.   

2.  There are many factors that can affect the amount of power that your computer system will require. For optimal system 

performance keep the load below 80% of the unit’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after 

receiving a new UPS, to ensure the battery’s maximum charge capacity, it is 

recommended that you charge the battery for at least 8 hours. Your UPS is 

equipped with an auto-charge feature. When the UPS is plugged into an AC 

outlet, the battery will automatically charge whether the UPS is turned on or 

turned off.

 

 

2.  With the UPS unit turned off and unplugged, connect your equipment requiring battery backup into the battery power 

supplied outlets. Plug the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection 

outlets. 

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large 

electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will 

overload and possibly damage the unit.

 

3.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall 

branch outlet is protected by a fuse or circuit breaker and does not service equipment 

with large electrical demands (e.g. air conditioner, refrigerator, copier, etc…). The 

warranty prohibits the use of extension cords, outlet strips, and surge strips.

 

 

4.  Press the power switch to turn the unit on. The Power On indicator light will illuminate 

green and the unit will “beep” twice. 

5.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS 

off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is 

depressed and then turn the UPS on. 

6.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7.  To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the 

battery every three months to ensure battery life. 

8.  For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.  Battery and Surge Protected Outlets 

The unit has three battery powered/surge suppression outlets to ensure temporary uninterrupted operation of your 
equipment during a power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, 

sump pump or other large electrical device into the “Battery and Surge Protected Outlets.” The power demands 
of these devices will overload and possibly damage the unit.)

 

2.  Full-Time Surge Protection Outlets 

The unit has three surge suppression outlets.

 

3.  Power On Switch 

To turn the UPS on, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - 
and release after a short beep. 
To turn the UPS off, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - 
and release after two short beeps. 
Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default setting is for the Alarm On. 
To turn the alarm off, quickly press the power button twice. You will hear two short beeps when the alarm is turned off. 
To turn the alarm back on, quickly press the power button twice. You will hear a short beep when the alarm is turned on. 
*When the alarm is turned off, there will be no audible notification when the UPS reaches a low battery state.

 

4.  Power On Indicator (green) 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and 
spikes.

 

5.  Electrical Wiring Fault Indicator (red) 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or 
reversed wiring.    If this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify 
the outlet is properly wired. The unit will not provide surge protection without being plugged into a grounded and 
properly wired wall outlet.

 

6.  Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.

 

7.  Outlets Designed for AC Adapters 

The UPS unit has two widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping 
adjacent outlets.

 

 

 

 

 

 

Power ON 

 

Wiring 

Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

Flash   

when beeps 

Off 

Beep twice   

every 30 seconds 

Utility Failure - Battery mode 

The UPS is providing power to battery power-supplied 

outlets from its battery. 

Flash   

when beeps 

Off 

Rapid Beeping 

every 1/2 second 

Utility Failure – Low Battery 

The UPS is providing battery power. Rapid beeping indicates 
the unit will run out of power shortly. 

On 

Off 

Constant tone 

Overload -

 Occurs when connected equipment exceeds the 

listed capacity of the UPS. Turn the UPS off, unplug at least 
one piece of equipment from battery outlets, reset the circuit 
breaker and turn the unit on. 

On/Off 

On 

None 

Electrical Wiring Fault - 

This 

indicates a wiring problem 

with the AC outlet

 such as bad ground, missing ground, or 

reversed wiring. Disconnect all electrical equipment from the 
outlet and have an electrician check the outlet to insure 
proper wiring. 

Off 

Off 

Constant tone 

Utility Failure- 

The frequency is beyond 47-63Hz. The UPS 

will not turn on in line mode.

 

 

 

 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection 
outlets stop providing power 
to equipment. Circuit 
breaker button is projecting 
from the side of the unit.

 

Circuit breaker has tripped due 
to an overload. 

Turn the UPS off and unplug at least one piece of 
equipment. Reset the circuit breaker by depressing 
the button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery is not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Please contact CyberPower Systems about 
replacement batteries. 

The UPS will not turn on. 

The on/off switch is designed 
to prevent damage from 
rapidly turning it off and on. 

Turn the UPS off. Wait 10 seconds and then turn the 
UPS on. 

The unit is not connected to an 
AC outlet. 

The unit must be connected to a 110/120V 50/60Hz 
outlet. 

The battery is worn out. 

Please contact CyberPower Systems about 
replacement batteries. 

Mechanical problem. 

Please contact CyberPower Systems. 

The frequency is beyond 
47-63Hz. 

Turn the UPS off. Make sure the frequency range is 
within 47-63Hz. Or you can turn on with battery 
mode. 

Additional troubleshooting information can be found at “Support” at 

www.cyberpower.com

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY WARNINGS 

 

EMI Filter 

Surge 

Suppressor 

Charger 

AC/DC 

Battery 

Inverter 

Input 

Output 

Normal Mode 

Battery Mode 

 