CyberPower Sinewave Series Скачать руководство пользователя страница 1

 

The  LCD  display  indicates  a 
variety  of  UPS  operational 
conditions. 

All 

descriptions 

apply when the UPS is plugged 
into the AC outlet and turned on 
or when the UPS is on battery. 

 
 
 
 

Smart App Sinewave Series 

PR1000LCDRTXL2UaTAA/PR1500LCDRTXL2UTAA/ 

PR2200LCDRTXL2UTAA 

User

’s Manual 

                                                                  K01-0000071-01 

 

 

 

This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read 

and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, 

or operate. 

CAUTION!

    The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an 

outlet that is not grounded.    If you need to de-energize this equipment, turn off and unplug the UPS.   

CAUTION!

   

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!

    CyberPower

 

Systems does not sell products for life support or 

medical  applications.  DO  NOT  use in  any  circumstance  that  would affect  operation  or  safety  of  any life  support  equipment,  with  any medical 

applications, or patient care. 

CAUTION!

    The battery can energize hazardous live parts inside even when the AC input power is disconnected. 

CAUTION!   

For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. 

CAUTION!

    To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area,  free  of  conductive 

contaminants. (Please see specifications for acceptable temperature and humidity range). 

CAUTION!

    To reduce the risk of electric shock, do not remove the cover, except to service the battery. There are no serviceable parts inside, 

except for the battery. 

CAUTION!

    To  avoid  electrical  shock,  turn  off  the  unit  and  unplug  it  from  the  AC  power  source  before  servicing  the  battery  or  installing  a 

computer component. 

CAUTION!

   

DO NOT USE WITH OR NEAR AQUARIUMS!

    To reduce the risk of fire, do not use with or near aquariums.    Condensation from 

the aquarium can come in contact with metal electrical contacts and cause the machine to short out. 

CAUTION!   

For model 

PR1000LCDRT2UaTAA, PR1500LCDRTXL2UTAA, PR2200LCDRTXL2UTAA, 

For use in a computer room as defined 

in the standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75. 
 
 
 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following. 

(1) UPS Unit; (1) User's Manual for UPS; (2) Rack mount Brackets; (2) Stands; (2) Skids; (1) Telephone Cable (black); (1) Emergency Power Off 

Cable  (gray);  (1)  PowerPanel

®

  Business  Edition  Software  CD;  (2)  Serial  Interface  Cable  (DB-9);  (1)  USB  A+B  type  cable;  (1)  Warranty 

Registration Card. 

 

OVERVIEW 

The

 

PR1000LCDRTXL2UaTAA/PR1500LCDRTXL2UTAA/PR2200LCDRTXL2UTAA 

provides 

battery 

backup,  automatic  voltage  regulation  (AVR),  and  optimal  performance  of  computers  and  other  network 

equipment 

by 

ensuring 

consistent 

sinewave 

power. 

The 

PR1000LCDRTXL2UaTAA/ 

PR1500LCDRTXL2UTAA/PR2200LCDRTXL2UTAA

 features 2060 Joules of surge protection, and provides 

battery  backup  during  power  outages.  The

  PR1000LCDRTXL2UaTAA/PR1500LCDRTXL2UTAA/ 

PR2200LCDRTXL2UTAA 

ensures consistent power to your computer system and its included software will 

automatically save your open files and shutdown your computer system during a utility power loss.

 

 

AUTOMATIC VOLTAGE REGULATOR(AVR)

 

The 

PR1000LCDRTXL2UaTAA/PR1500LCDRTXL2UTAA/PR2200LCDRTXL2UTAA

  stabilizes  inconsistent  utility  power.  The  incoming  utility 

power  may be damaging to important data and hardware, but with Automatic Voltage Regulation, the computer will not experience damaging 

voltage levels. An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v. 

The unit powerful sealed lead-acid batteries will provide power only if the incoming voltage drops below 80v or increases above 150v. 

 

SYSTEM BLOCK DIAGRAM 

 

 

 

 

 

 

 

 

 

 

 

 

 

HARDWARE INSTALLATION GUIDE 

1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least four hours 

is  recommended  to  ensure  that  the  battery's  maximum  charge  capacity  is  achieved.  Charge  loss  may  occur 

during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit 

will charge in both the on and off position.   

2. If you plan to use the included software, connect either the serial cable or the USB cable to the corresponding 

port  on  the  UPS  and  the  computer.  Note:  if  the  USB  port  is  used  the  serial  port  will  be  disabled.  To  control 

multiple computers install PowerPanel

®

 Business Edition Agent on the computer connected with the USB cable 

and PowerPanel

®

 Business Edition Slave on the remaining computers. 

3.  With  the  UPS  unit  off  and  unplugged,  connect  your  computer,  monitor,  and  any  externally  powered  data 

storage  device  (Hard  drive,  Tape  drive,  etc.)  into  the  battery  power  supplied  outlets.    DO  NOT  plug  a  laser 

printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS. The power 

demands of these devices will overload and possibly damage the unit.   

4. To protect a fax, telephone, modem line or network cable, connect a telephone cable or network cable from the 

wall jack outlet to the IN jack of the UPS. Then connect a telephone cable or network cable from the OUT jack on 

the UPS to the modem, computer, telephone, fax machine, or network device.   

5.  Plug  the  UPS  into  a  2  pole,  3  wire  grounded  receptacle (wall outlet).    Make  sure  the wall  branch  outlet is 

protected  by  a  fuse  or  circuit  breaker  and  does  not  service  equipment  with  large  electrical  demands  (e.g.  air 

conditioner, refrigerator, copier, etc.). Avoid using extension cords.     

6.  Depress  the power  switch  to turn  the unit  on.  The  Power  On indicator light  will illuminate.  If  an  overload is 

detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and 

unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the 

circuit breaker is depressed and then turn the UPS on. 

7. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will 

automatically recharge. 

8. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

9. To store your UPS for an extended period, cover it and store with the battery fully charged.    Recharge the 

battery every three months to ensure battery life. 

10.  Professional  Rack  Mount  UPS  provide  one  serial  port,  one  dry  contact  port,  and  one  USB  port  to  allow 

communication  between  the  UPS  and  computers  or  equipment.  The  dry  contact  port  (Serial  Port  II)  signals 

information for equipment that can utilize a dry contact UPS. The primary computer, with PowerPanel

®

 Business 

Edition installed,  connected  to  Serial  Port  I  or  the  USB  port is  the  computer  that  you  use  to  control  the  UPS. 

When there is a power failure, the primary computer which connects to Serial Port I or the USB port will start to 

shutdown after a user controlled delay. PowerPanel

®

 Business Edition Agent software will save and close any 

open files prior to shutting the system down and signal any configured slaves to shutdown. 

11. EPO (Emergency Power Off) Port: 

The feature is used with EPO controllers.    Use the provided gray cable to connect to an EPO contact switch.   

Follow  the  appropriate  circuit  diagram  below  to  wire  the  cable  to  match  your  EPO  configuration.

 

For  model 

PR1000LCDRT2UaTAA, PR1500LCDRTXL2UTAA, PR2200LCDRTXL2UTAA

-

 

EPO function is provided in the 

UPS. EPO remote switch which is a Push-Back button installed computer room outside by a phone line, and not 

connected any other equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT / REAR PANEL DESCRIPTION 

1

.

 Power Switch

 

Master on/off switch for equipment connected to the UPS. 

2. Power On Indicator 

Indicates the power is on.   

3. LCD Module Display 

LCD shows all the UPS information with icons and messages. 

4

.

 LCD Display Toggle Button 

The button can be used to toggle between different data displays 

on the LCD.   

5

Battery Backup Protected Outlets 

Provides eight battery powered, surge protected and AVR outlets 

for  connected  equipment  and  ensures  temporary  uninterrupted 

operation of connected equipment during a power failure. 

Critical /Non-critical   

When the UPS is overloaded, the circuit breakers will be tripped 

to  interrupt  the  power  supply  to  the uncritical  outlets  while 

continuing  to  supply  the  critical  outlets.  As  well,  as  the  battery 

capacity depletes under the threshold value, the uncritical outlets 

will

 

be  shut  down  and  provide  energy  for  critical  outlets.  The 

threshold  can  be  determined  and  set  by  users.  Non-critical 

outlets can also be turned on/off manually through the software 

package

 

provided. 

6

.

 Input Power Cord 

Heavy-duty, extra long power cord.

 

7

Output Circuit Breaker

 

Resettable circuit breakers provide output outlets protection from 

overload. 

8

.

 Input Circuit Breaker 

Resettable  circuit  breakers  provide  Input  optimal  overload 

Protection. 

9

USB port

USB communication port for management software. 

10. Protected Communication Ports RJ11/RJ45

 

Ports protect standard single line modem, fax, telephone line or 

network cable. 

 

 

 

 

 

Contact  your  dealer,  or  email  [email protected].  Refer  to  replacement  battery  pack  number 

RBP852

 

for 

PR1000LCDRTXL2UaTAA/ 

PR1500LCDRTXL2UTAA/ PR2200LCDRTXL2UTAA

. For model 

PR1000LCDRT2UaTAA/PR1500LCDRTXL2UTAA/PR2200LCDRTXL2UTAA 

can support model 

BP48V75ART2UTAA

 for external battery pack.

   

 

Read  and  follow  the  IMPORTANT  SAFETY  INSTRUCTIONS  before  servicing  the  battery.    Service  the  battery  under  the  supervision  of 

personnel knowledgeable of batteries and their precautions

. Servicing the battery should only be performed by trained personnel.

 

Replacement of batteries located in an 

OPERATOR ACCESS AREA.

 

CAUTION!

    When  replacing  batteries,  replace  with  the  same  number  of  the  following  battery:  HR9-12(BB)  for 

PR1000LCDRTXL2UaTAA/ 

PR1500LCDRTXL2UTAA/ PR2200LCDRTXL2UTAA

,

 

CAUTION!   

Risk  of  Energy  Hazard,  12  V,  maximum  9Ampere-hour  battery  (HR9-12).  Before  replacing  batteries,  remove  conductive  jewelry 

such as chains, wrist watches, and rings. High energy through conductive materials could cause severe burns. 

CAUTION!

    Risk of battery explosion, if battery is replaced by an incorrect type. Dispose of used battery according to the instructions. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  overcurrent  protection  in 

accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!

    Use only the specified CyberPower replacement battery, or battery pack. See your dealer for details. 

CAUTION!   

The  battery  may  present  a  risk  of  electrical  shock.  Do  not  dispose  of  batteries  in  a  fire,  as  they  may  explode.  Follow  all  local 

ordinances regarding proper disposal of batteries. 

CAUTION!

    Do not open or mutilate the batteries. Released electrolyte is harmful to the skin and eyes and may be toxic. 

CAUTION!   

A battery may present a high risk of short circuit current and electrical shock. 

 

Take the following precautions before replacing the battery

1. Remove all watches, rings or other metal objects. 

2. Only use tools with insulated handles. 

3. Do not lay tools or metal parts on top of battery or any terminals. 

4. Wear rubber gloves and boots. 

5. Determine if the battery is inadvertently grounded.    If inadvertently grounded, remove  source of ground. 

CONTACT WITH A GROUNDED 

BATTERY CAN RESULT IN ELECTRICAL SHOCK! 

The likelihood of such shock will be reduced if such grounds are removed during installation 

and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit) 

 

BATTERY REPLACMENT PROCEDURE: 

 

 

 

 

 

 

 

.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT voltage meter: 

INPUT voltage meter: This meter measures the AC voltage that the UPS system is 

receiving from the utility wall outlet. The INPUT voltage readout can be used as a diagnostic tool to identify 

poor-quality  input  power.  The  AVR  in  this  UPS  continuously  conditions  the  power  to  a  stable  110/120V 

output to connected equipment.    In the event of a complete power loss, severe brownout, or over voltage, 

the UPS relies on its internal battery back up to supply a consistent 110/120V output.

 

OUTPUT  voltage  meter:

  This  meter  measures,  in  real  time,  the  AC  voltage  that  the  UPS  system  is 

providing to the computer, such as normal line mode, AVR mode and battery back up mode. 

Note: The OUTPUT voltage readout displays the status of the battery back up outlets. 

ESTIMATE RUN TIME:

 This displays the run time estimate of the  UPS with the current battery capacity 

and load. 

NORMAL icon:

 This icon appears when the UPS is working under normal conditions. 

BATTERY icon:

 During a severe brownout or blackout, this icon appears and an alarm sounds (two short 

beeps followed by a pause) to indicate the UPS is operating from its Internal batteries. During an extended 

brownout  or  blackout  that  drains  the  battery,  a  continuous  alarm  will  sound  (and  the  BATT.  CAPACITY 

readout will show a single shaded segment, equaling 20% battery capacity remaining) indicating the UPS 

batteries are nearly out of power. If this occurs, it is recommended that you save your files and manually 

power down your equipment immediately.     

Automatic Voltage Regulation (AVR) icon

: This icon appears whenever your UPS is automatically correcting low AC input line voltage without 

using battery power. This is a normal, automatic operation of your UPS, and no action is required. 

SILENT  MODE  icon:

  This  icon  appears  whenever  the  UPS is in  silent  mode.  The buzzer  does  not  beep  during  silent  mode  until  the battery 

reaches low capacity. 

OVER LOAD icon:

 This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug 

some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops. 

FAULT icon:

 

This icon appears if there is a problem with your UPS.     

BATT.

 

CAPACITY meter: 

This meter displays the approximate charge level (in 20% increments) of the UPS's internal battery. During a blackout 

or severe brownout the UPS switches to battery back up power the BATT. CAPACITY icon appears and the charge level decreases. 

LOAD CAPACITY:

 This meter displays the approximate output load level (in 

20% increments) of the UPS’s battery outlets. 

IMPORTANT SAFETY WARNINGS

 

INSTALLING YOUR UPS SYSTEM 

1.Remove the six retaining screws, 

and remove the front panel. 

2. Remove the two retaining screws of 

the cable protection cover then remove 

the cover. 

3.  Remove  the  two  retaining  screws  of  the  cable 

connectors. 

4. Disconnect the black and red cable

 

5. Remove the three retaining screws. 

6.  Pull  out  the  old  battery  pack  and  replace. 

Reassemble the retaining screws, covers, black and 

red  cable,  and  front  panel  in  the  reverse  sequence 

of the above steps. Recharge the unit for 4-8 hours 

to ensure maximum UPS battery runtime. 

LCD STATUS DEFINITION 

BATTERY REPLACEMENT 

11. Site Wire Fault Indicator

 

This LED will illuminate to warn the user that a wiring problem exists within 

the AC receptacle, such as a bad ground or reversed wiring. If illuminated, 

disconnect  all  equipment  and  contact  an  electrician  to  ensure  outlet  is 

properly wired. 

12. Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS surge protection ports will protect any cable Modem, 

CATV converter or DSS receiver. 

13. Serial Port I 

Serial port allows connection and communication between the UPS and the 

computer.

 

 

14. Serial Port II   

Serial  Port  II  relays  information  to  equipment  that  can  utilize  a  contact 

closure UPS. 

15. SNMP/HTTP Network slot 

Remove  the  cover  panel  to  install  optional  RMCARD  that  allows  remote 

monitoring and control of your UPS on a network 

16. EPO (Emergency Power Off) Port: 

The EPO interface enables connection to an EPO master switch.

   

17. Ground Stud 

Use the Ground Stud to ground the UPS. 

18.External Battery Pack Connector: 

Provides a connection for additional CyberPower external battery packs for 

extended runtime. 

Primary Computer-
Install PowerPanel

®

 

Business Edition

Install PowerPanel

®

 

Business Edition 
software on the primary 
computer connected to 
the UPS with either a 
serial cable or a USB 
cable.

The equipment can 
read information 
from dry contact

*Dry connect is controlled by the PowerPanel

®

 Software, 

please go to 

www.cyberpowersystems.com

 for free download. 

*NOTE: Both USB and Serial can not be used simultaneously

.

BASIC OPERATION

 

When  you  first  receive  the 

unit,  plug  in  the  unit  to  fully 

charge the battery. 

Unplug the unit and turn Power 

Off  when  first  connecting  your 

computer and peripherals. 