CyberPower P705G Скачать руководство пользователя страница 1

CONGRATULATIONS ON YOUR PURCHASE

Thank you for selecting the CyberPower P705G Surge Protector. 

This manual explains the features and operation of the P705G. 

Please take a few moments to read this manual.

FEATURES

1.  Protected LED Indicator

Illuminated when the surge protection feature is working properly.

2. Grounded LED Indicator

Illuminated when the ground protection feature is working properly.

3. ON/OFF Reset Control Switch and Circuit Breaker

Controls power to all outlets. The switch is also a 15 A breaker. 

When an overload occurs, it will automatically switch off. To 

resume operation, ensure the overload condition is removed 

and reset the surge protector by switching the unit ON.

4. Safety Covers

All outlets on this surge protector include safety covers. Slide 

the plastic outlet cover over outlets that are not used. This 

ensures the safety of children and prevents potential electric

shocks and damage caused by highly dusty environments.

5. Always-On Grounded Outlets (2)

Provides continuous power regardless of whether the Master 

and Master controlled outlets are on or off.

6. Energy-Saving Master Controlled Grounded Outlets (4)

Automatically switched on or off by master outlet.

7. Energy-Saving Master Grounded Outlet

Automatically switches four master controlled outlets on or off.

8. Transformer-spaced Grounded Outlet (1)

Easily plug in large chargers without interfering with the 

other outlets.

9. Threshold Switch

Adjusts the threshold at which the energy saving outlets adjust 

the switch according to the device plugged into the Master outlet.

High mode: For high wattage devices such as a TV or PC.

Low mode: For low wattage devices such as a laptop.

SPECIFICATIONS

• Model Number: P705G

• Outlets: Standard Grounded Outlets (6) and Transformer-spaced 

Grounded Outlet (1)

• Surge Protection: 2,100 Joules

• Electrical Rating: 125 V/15 A/1875 W

• UL Clamping Voltage: UL 1449 3rd/400 V (L-N, L-G, N-G)

• Maximum Peak Current: 105,000A

• 3 AC Lines Protected: 

L-N: 45,000 A

L-G: 30,000 A 

N-G: 30,000 A

The maximum surge possible on household wiring is 6,000 volts)

• Response Time: Less than 1 nanosecond

• Attenuation: Up to 32 dB

• Circuit Breaker: Resettable 15 Amp

• EMI/RFI Filtration: 150 kHz to 100 MHz

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK

 - Use only in dry 

locations and only indoors. 

DO NOT

 plug into another relocatable 

power tap. 

DO NOT

 “daisy chain” surge protectors. 

DO NOT

 use 

with any aquarium equipment. 

DO NOT

 use if properly grounded 

outlets are not available. 

DO NOT

 install this device if there is less 

than 10 meters (30 feet) or more of wire between the electrical 

outlet and electrical service panel. 

DO NOT

 use for medical or life 

support equipment. This device features an internal protection 

that will disconnect the surge protective component at the end 

of its useful life, but it will maintain unprotected power to the 

load. If this situation is undesirable for the application, follow the 

manufacturer’s instructions for replacing the device. 

TROUBLESHOOTING

▪ 

If the ON/OFF is switched OFF, the 15 Amp circuit breaker may 

have tripped. Examine your connected equipment and remove 

the device that is overloading the circuit. Then, turn the ON/OFF 

switch back to RESET.

▪ 

If the grounded indicator does not light when you plug in the 

surge protector, move the surge protector to a different 

grounded three-prong AC outlet. If it still does not light, return 

the product to the retailer for assistance. If the surge protector 

appears to be working properly, your outlets may not be 

properly grounded and need to be repaired by a professional 

electrician. If the grounded indicator turns off after a period of 

use, the surge protection has been depleted. Replace your 

surge protector.

▪ 

If the protected indicator does not light, the surge protector’s 

AC lines are no longer protected from surge. The surge protector 

may have received a power surge or spike beyond its specified 

limits that overloaded the protection circuitry and rendered it 

inactive. The surge protector has protected your connected 

equipment as designed, but it will not protect against future 

surges, and spikes. It should be replaced.

▪ 

If the Master-controlled outlets don't turn on or off when your 

laptop computer or TV is connected to the Master outlet:

1.  The power drawn from the Master Outlet must be below the 

threshold setting (High/Low) for the Master Controlled 

Outlets to turn off. Some computers will continue to consume 

power during battery charging or in standby mode. In this 

case, please make sure hibernate or sleep mode is enabled on 

your computer.

2. The power drawn from the Master Outlet must be above the 

threshold setting (High/Low) for the Master Controlled 

Outlets to turn on. Some computers and TVs will not draw 

enough power to turn on the Master Controlled outlets. In this 

case, please try plugging a different primary device into the 

Master Outlet or make sure the threshold switch is set to Low.

TECHNICAL SUPPORT

Please contact our Tech Support Department with installation, 

troubleshooting, or general product questions.
• Phone: 1-877-297-6937
• Email: [email protected]
• Hours of Operation: Monday – Friday 7:00am – 6:00pm CST

USER MANUAL

7-Outlet Energy Saving 

Surge Protector

P705G

7-Outlet Energy Saving 

Surge Protector

P705G

1

2

Copyright © 2019 Cyber Power Systems (USA), Inc. All rights reserved.

1

2
3

4

6

5

7

9

8

Отзывы: