CyberPower OL6KRT2UTF Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 
 

User’s Manual 

Step-Down Transformer

 

OL6KRT2UTF 

OL8K10KRT3UTF 

OL6KRT2UTFHW

 

OL8K10KRT3UTFHW

 

 

 

 

 

 

CyberPower Systems (USA), Inc. 

4241 12th Avenue East Suite 400 Shakopee, MN 55379 

Phone: 877-297-6937 

Fax: 952-403-0009 

www.CPSww.com

 

 

 

 

K01-0000212-01 

Содержание OL6KRT2UTF

Страница 1: ...ep Down Transformer OL6KRT2UTF OL8K10KRT3UTF OL6KRT2UTFHW OL8K10KRT3UTFHW CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403 0009 www CPSww com...

Страница 2: ...Power UPS systems When combined with the UPS the Step Down Transformer converts voltage from 200 240V down to 100 120V 2U or 3U Step Down Transformer User s manual Registration card Rackmount left rai...

Страница 3: ...hes deep Select the proper holes in the rack for positioning the Step Down Transformer in the rack The 2U Step Down Transformer takes up position 1 through position 6 The 3U Step Down Transformer take...

Страница 4: ...odule Step 3 Attach dust covers Insert dust covers into the rackmount ear screw holes that are not being used SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidit...

Страница 5: ...KRT2UTFHW and OL8K10KRT3UTFHW require them to be hard wired into the UPS Only qualified maintenance personnel should perform this task CHECK WIRING Check wiring dimensions with the following table Ste...

Страница 6: ...CyberPower Systems Inc HARDWIRING THE INPUT OUTPUT TERMINALS 5 Step 3 Input configuration Insert the input cable through the appropriate cable gland not included Connect the three wires to the input...

Страница 7: ...Inc HARDWIRING THE INPUT OUTPUT TERMINALS 6 Step 4 Fix the top cover on the bottom cover Tighten the five screws to fix the top cover on the bottom cover Step 5 Connect the other side of the input ca...

Страница 8: ...ackup and surge protection They ensure power is provided to connected equipment over a period of time during a power failure 4 Output Circuit Breaker 120Vac Provides output overload and fault protecti...

Страница 9: ...6KRT2UTFHW OL8K10KRT3UTF OL8K10KRT3UTFHW Configuration Maximum Output Power VA 5000VA 6000VA 5000VA 8000VA Maximum Output Power W 5000W 5400W 5000W 7200W Form Factor Rackmount Tower Input Nominal Inpu...

Страница 10: ...hase Date and each item of Connected Equipment 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated purchase receip...

Страница 11: ...1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on pro...

Страница 12: ...interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC lim...

Отзывы: