CyberPower LE1000DG Скачать руководство пользователя страница 1

YOUR ULTIMATE ALLY IN POWER 

STANDBY UPS SERIES 

LE850G / LE1000DG 

USER MANUAL 

LE850G 

LE1000DG 

FEATURES 

1.  Battery and Surge Protected Outlets 
2.  Full-Time Surge Protection Outlets 
3.  Power Switch 
4.  Power On Indicator 
5.  Mute Button (LE850G) 
6.  Fault Indicator (LE850G) 
7.  Mode Switch (LE1000DG) 

8.  LCD Module Display (LE1000DG) 
9.  USB Port 
10.  Communication Protection Ports 
11.  Circuit Breaker 
12.  Ground Screw 
13.  Outlets Designed for AC Adapters 

Cyber Power Systems (USA), Inc. 

4241 12th Avenue East, Suite 400  |  Shakopee, MN 55379  | 

CyberPowerSystems.com 

Содержание LE1000DG

Страница 1: ...tion Outlets 3 Power Switch 4 Power On Indicator 5 Mute Button LE850G 6 Fault Indicator LE850G 7 Mode Switch LE1000DG 8 LCD Module Display LE1000DG 9 USB Port 10 Communication Protection Ports 11 Circuit Breaker 12 Ground Screw 13 Outlets Designed for AC Adapters Cyber Power Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 CyberPowerSystems com ...

Страница 2: ...e aquarium can cause the unit to short out DO NOT USE THE UPS ON ANY TRANSPORTATION To reduce the risk of fire or electric shock do not use the unit on any transportation such as airplanes or ships The efect of shock or vibration caused during transit and the damp environment can cause the unit to short out CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity...

Страница 3: ...ed of 2 With the UPS unit turned of and unplugged connect your equipment requiring battery backup into the battery power supplied outlets Plug the other peripheral equipment printer scanner speakers into the full time surge protection outlets DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical device into the Battery and Surge Protected Outlets...

Страница 4: ...rned Of To turn the Alarm back On quickly press the power button twice You will hear a single short beep when the Alarm is turned On When the Alarm is turned Of there will be no audible notifcation when the UPS reaches a low battery state 4 Power On Indicator This LED is illuminated when the utility power is normal and the UPS outlets are providing power free of surges and spikes 5 Mute Button LE8...

Страница 5: ...0A for LE1000DG current The following precautions should be observed when working on batteries 2 CAUTION Risk of Energy Hazard 24 V maximum 9 Ampere hour battery Before 1 Remove watches rings or other replacing batteries remove conductive metal objects jewelry such as chains wrist watches and 2 Use tools with insulated handles rings High energy conducted through these materials could cause severe ...

Страница 6: ...connected to a 120V 60Hz outlet The UPS will not turn on The battery is worn out Contact CyberPower Systems about replacement batteries at cyberpowersystems com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support The frequency is beyond 57 to 63 Hz Turn the UPS of Make sure the frequency range is within 57 to 63 Hz Or you can turn on with battery mode The USB cab...

Страница 7: ...nsistent 110 120 output voltage The INPUT voltage meter can be used as a diagnostic tool to identify poor quality input power OUTPUT Voltage Meter This meter measures in real time the AC voltage that the UPS system is providing to the computer during normal AC Utility Power mode and battery backup mode ESTIMATED RUNTIME This displays the run time estimate of the UPS with the current battery capaci...

Страница 8: ...east one piece of TECHNICAL SPECIFICATIONS Model LE850G LE1000DG Capacity 850 VA 460W 1000 VA 530 W Nominal Input Voltage 120 VAC Input Frequency 60 Hz 3 Hz On Battery Output Voltage 120 VAC 5 Automatic Voltage Regulator AVR Yes On Battery Output Frequency 60 Hz 1 Max Load for UPS Outlets 850 VA 460W 1000 VA 530 W Max Load for Full Time Surge Protection Outlets 12 Amps On Battery Output Wave Form ...

Страница 9: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit diferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Changes or modifcations...