background image

Thank you for purchasing a CyberPower product.  This UPS is designed to provide unsurpassed 

power protection, operation, and performance during the lifetime of the product. Please take a 

few minutes to register your product at: 

www.CyberPowerSystems.com/registration

.  

Registration certifies your product’s warranty, confirms your ownership in the event of a product 

loss or theft, and entitles you to free technical support. Register your product now to receive the 

benefits of CyberPower ownership.

CAUTION! 

 To prevent the risk of fire or  

electric shock, install in a temperature and 

humidity controlled indoor area free of  

conductive contaminants. (Please see  

specifications for acceptable temperature  

and humidity range.) 

CAUTION!

 To reduce the risk of electric shock, 

do not remove the cover except to service the 

battery. Turn off and unplug the unit before

servicing the batteries. There are no user ser-

viceable parts inside except for the battery.

CAUTION!

 Hazardous live parts inside can be 

energized by the battery even when the AC 

input power is disconnected.

CAUTION!

 The UPS must be connected to an 

AC power outlet with fuse or circuit breaker 

protection. Do not plug into an outlet that is 

not grounded. If you need to de-energize this 

equipment, turn off and unplug the unit.

CAUTION!

 To avoid electric shock, turn off the 

unit and unplug it from the AC power source 

before installing a computer component.

CAUTION!

 To reduce the risk of fire, connect 

only to a circuit provided with 20 amperes 

maximum branch circuit over current protec-

tion in accordance with the National Electric 

Code, ANSI/NFPA 70.

CAUTION!

 Not for use in a computer room as 

defined in the Standard for the Protection of 

Electronic Computer/Data Processing Equip-

ment, ANSI/NFPA 75.

CAUTION!

 Do not dispose of batteries in a fire. 

The batteries may explode.

CAUTION!

 Do not open or mutilate batteries. 

Released electrolyte is harmful to the skin and 

eyes. It may be toxic.

DO NOT USE FOR MEDICAL  

OR LIFE SUPPORT EQUIPMENT!

  

CyberPower Systems does not sell products 

for life support or medical applications. DO 

NOT use in any circumstance that would affect 

operation and safety of life support equip-

ment, any medical applications or patient care.

DO NOT USE WITH OR NEAR AQUARIUMS!

  

To reduce the risk of fire or electric shock, do 

not use with or near an aquarium. Condensa-

tion from the aquarium can cause the unit to 

short out.

DO NOT USE THE UPS  

ON ANY TRANSPORTATION!

  

To reduce the risk of fire or electric shock, do 

not use the unit on any transportation such 

as airplanes or ships. The effect of shock or 

vibration caused during transit and the damp 

environment can cause the unit to short out.

PRODUCT REGISTRATION

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to 

unpack, install, or operate your UPS.

Содержание CP1350PFCLCD

Страница 1: ...On Indicator 3 LCD Module Display 4 Down Display Button 5 Up Mute Button 6 Enter Setup Button 7 USB charge ports Except for CP1350PFCLCD 8 Battery and Surge Protected Outlets 9 Full Time Surge Protection Outlets 10 Circuit Breaker 11 DB9 USB Ports to PC 12 Wiring Fault Indicator red 13 Communication Protection Ports RJ45 14 SNMP HTTP Network Slot Except for CP1350PFCLCD 15 Widely Spaced Outlets De...

Страница 2: ...ing a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equip ment ANSI NFPA 75 CAUTION Do not dispose of batterie...

Страница 3: ...low utility power to a consistent and safe 110 120 volts If incoming utility voltage drops below 90 volts or exceeds 140 volts the units auto matically switch to battery back up power DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the UPS does not exceed the UPS unit s rated capacity If the rated capacities of the unit are exceeded an overload condition...

Страница 4: ... the wall outlet and UPS are located near the equipment being attached for proper accessibility SYSTEM FUNCTION BLOCK DIAGRAM EMI Filter Surge Suppressor AVR Charger AC DC Battery Inverter Input Output Normal Mode Battery Mode Advanced Energy Saving Patented Bypass Technology CyberPower s patented GreenPower UPS with Bypass Technology reduces UPS energy costs by up to 75 compared to conventional U...

Страница 5: ... unit has 6 battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum cleaner sump pump or other large electrical device into the Battery and Surge Protected Outlets The power demands of these devices will overload and possibly damage the unit 9 Full Time Sur...

Страница 6: ...O LOCAL REGULATIONS REPLACING THE BATTERY BATTERY REPLACEMENT PROCEDURE CP1350PFCLCD CP1500PFCLCD 1 Turn off and unplug all connected equipment 2 Turn the UPS off and unplug it from the AC power source 3 Turn the UPS on its side 4 Remove the front panel retaining screws located on the bottom of the UPS 5 Slide the front panel completely off of the unit 6 Remove the fixed stand from the upper batte...

Страница 7: ...ult Overcharge Contact CyberPower Systems for support E02 Charger Fault No Charge Contact CyberPower Systems for support E11 Battery Overvoltage Contact CyberPower Systems for support E21 Battery Output Short Fault Turn on the UPS E22 Battery Mode or AC Utility Power Mode Overload Fault Unplug at least one piece of equipment from battery outlets and turn the UPS on again 8 OVERLOAD This icon appea...

Страница 8: ... Systems at cyberpowersystems com support PowerPanel is inactive all icons are gray The USB cable is not connected Connect the USB serial cable to the UPS unit and an open USB serial port on the back of the computer You must use the cable that came with the unit The USB cable is connected to the wrong USB port Check the back of the computer for an additional USB serial port Move the cable to this ...

Страница 9: ...n turn the UPS on Additional troubleshooting information can be found at Support at www CyberPowerSystems com Model CP1350PFCLCDa CP1500PFCLCDa Capacity 1350VA 880W 1500VA 1000W Nominal Input Voltage 120V Input Frequency 60 Hz 3 Hz On Battery Output Voltage 120Vac 5 Max Load for UPS Outlets 5 Outlets 1350VA 880W 1500VA 1000W Max Load for Full Time Surge Protection outlets 12 Amp On Battery Output ...

Страница 10: ...ed and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio co...