Chapter 3
:
Replacing Components and Preventive Maintenance
70
SE500
ULTRA
Hardware Manual
Checking the Emergency Stop Functionality
Perform this procedure monthly or more frequently if required.
Stop all movement on the SE500
ULTRA
system by using the Emergency Stop (E-Stop) button.
Motion will also stop when a safety interlock is disengaged.
When the E-Stop button is pushed, all motion in the system stops and power is removed from
their circuitry.
Figure 40.
Emergency Stop Button
➢
To check the E-Stop functionality
1. Push the red E-Stop button to stop the conveyor and stage movement.
2. Twist and pull the E-Stop button to disengage, then press the yellow E-Stop Reset button to
restart the system.
When the E-Stop button is pressed, or an interlock is broken, the E-Stop button will light up,
giving an indication of the machine status. After clearing the E-Stop button or securing the
interlock, the light turns off.
Caution
: Always press the Emergency Stop button before clearing a conveyor malfunction,
before performing machine maintenance, or before reaching inside the machine for any reason.
E-Stop
E-Stop Reset
i
Note:
Air is still supplied to the conveyor panel lifter and the conveyor clamps after pressing the
E-Stop button but they will return to lift down or clamps up when E-Stop button is activated.
Содержание SE500ULTRA
Страница 1: ...SE500ULTRA Hardware Manual ...
Страница 6: ...Contents vi SE500ULTRA Hardware Manual ...
Страница 10: ...x SE500ULTRA Hardware Manual This page is intentionally left blank ...
Страница 28: ...Chapter 1 System Overview 18 SE500ULTRA Hardware Manual Dimensions Figure 8 Front View ...
Страница 30: ...Chapter 1 System Overview 20 SE500ULTRA Hardware Manual ...
Страница 163: ...CyberOptics Corporation 153 AC and DC Distribution Block Diagram AC and DC Distribution Block Diagram ...
Страница 184: ...Chapter 5 System Drawings 174 CyberOptics Corporation ...