2.3.10 Configure the Sensor Page Parameters
The door sensor (pins 1 and 2) on the terminal block can be used to monitor a door's open or closed
state. There is an option on the
to trigger on an open or short condition on these pins.
The door sensor alarm will be activated when the
parameter has
been met.
Each sensor can trigger up to five different actions:
•
Flash the LED until the sensor is deactivated (roughly 10 times/second)
•
Activate the relay until the sensor is deactivated
•
Loop an audio file out of the speaker until the sensor is deactivated
•
Call an extension and establish two way audio
•
Call an extension and play a pre-recorded audio file
Note
Calling a preset extension can be set up as a point-to-point call, but currently can't send
delayed DTMF tones.
1. Click
Sensor
menu button to open the
(