Quick Reference 

931958A

© 2022, CyberData Corporation, ALL RIGHTS RESERVED

© 2022, CyberData Corporation, ALL RIGHTS RESERVED

931958A

Quick Reference 

RTFM Switch

Contacting CyberData

1.0" [25 mm]

Dimensions are in Inch [Millimeters]

Paper Clip

RTFM

Cover Screw

RTFM Access

The RTFM switch access will be on the top side of the horn hidden under a screw that will be used to keep the unit IP66 
sealed with the gasket washer. To access the RTFM, complete the following steps:

1. Remove the RTFM cover screw to gain access to the RTFM switch (see the figure below).

2. Use a paper clip to feed through the hole to press the RTFM switch (see the figure below).

Announce the IP Address

To broadcast the device’s current IP address, press and hold the RTFM switch for a couple of seconds and then release 
it.

Restore the Factory Default Settings

To restore the factory defaults, complete the following steps:

1. Press and hold the RTFM switch until you hear the device announce the words, “restoring defaults” and “rebooting”. 

2. Release the RTFM

 

switch. The device will be restored to the factory default settings.

Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website:

 

https://support.cyberdata.net/

RMA Department Contact and Status: 

https://support.cyberdata.net/

Warranty Information: 

https://support.cyberdata.net/

Corporate Headquarters

CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA

Phone: 831-373-2601
Fax: 831-373-4193

https://www.cyberdata.net/

Typical System Installation

Getting Started

Download the 

Operations Guide

 PDF file from the 

Documents

 tab at the following webpage:

https://www.cyberdata.net/products/011457

Create a plan for the locations of your paging amplifiers.

WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.

WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation 

instructions.

WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.

WARNING: The SIP IP66 Indoor/Outdoor Horn enclosure is not rated for any AC voltages!

Parts

Parameter

Factory Default Setting

IP Addressing

DHCP

IP Address

a

a. Default if there is not a DHCP server present.

192.168.1.23

Web Access Username

admin

Web Access Password

admin

Subnet Mask

a

255.255.255.0

Default Gateway

a

192.168.1.1

*

See the 

Operations Guide for 

more 

installation options.

802.3at Compliant PoE Switch

VoIP Phone

IP-PBX Server

SIP IP66 Outdoor Horn

(1) Assembly

The IP Endpoint Company

Installation Quick Reference

SIP IP66 Indoor/Outdoor Horn

011457