Quick Reference
931958A
© 2022, CyberData Corporation, ALL RIGHTS RESERVED
© 2022, CyberData Corporation, ALL RIGHTS RESERVED
931958A
Quick Reference
RTFM Switch
Contacting CyberData
1.0" [25 mm]
Dimensions are in Inch [Millimeters]
Paper Clip
RTFM
Cover Screw
RTFM Access
The RTFM switch access will be on the top side of the horn hidden under a screw that will be used to keep the unit IP66
sealed with the gasket washer. To access the RTFM, complete the following steps:
1. Remove the RTFM cover screw to gain access to the RTFM switch (see the figure below).
2. Use a paper clip to feed through the hole to press the RTFM switch (see the figure below).
Announce the IP Address
To broadcast the device’s current IP address, press and hold the RTFM switch for a couple of seconds and then release
it.
Restore the Factory Default Settings
To restore the factory defaults, complete the following steps:
1. Press and hold the RTFM switch until you hear the device announce the words, “restoring defaults” and “rebooting”.
2. Release the RTFM
switch. The device will be restored to the factory default settings.
Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website:
https://support.cyberdata.net/
RMA Department Contact and Status:
https://support.cyberdata.net/
https://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
Typical System Installation
Getting Started
•
Download the
Operations Guide
PDF file from the
Documents
tab at the following webpage:
https://www.cyberdata.net/products/011457
•
Create a plan for the locations of your paging amplifiers.
•
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
•
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
•
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•
WARNING: The SIP IP66 Indoor/Outdoor Horn enclosure is not rated for any AC voltages!
Parts
Parameter
Factory Default Setting
IP Addressing
DHCP
IP Address
a
a. Default if there is not a DHCP server present.
192.168.1.23
Web Access Username
admin
Web Access Password
admin
Subnet Mask
a
255.255.255.0
Default Gateway
a
192.168.1.1
*
See the
Operations Guide for
more
installation options.
802.3at Compliant PoE Switch
VoIP Phone
IP-PBX Server
SIP IP66 Outdoor Horn
(1) Assembly
The IP Endpoint Company
Installation Quick Reference
SIP IP66 Indoor/Outdoor Horn
011457