ESCRIPTION
E87
Unknown error
An unknown error occurred while trying to program an option.
Contact Cybelec.
E88
RS232: port already open
E89
Solution not found
This message indicates that the bending sequence automatic search
did not find any solution. Try to create the bending sequence
manually. If not possible, it means that this part is not feasible on
this machine.
E90
Too many buttons on bend num
page
Too many buttons are configured for the available space on the
. The last one, and all the following will be
refused. A technician must check the configuration.
E91
Next program error
This message appears when there has been a problem with the
. The problem appeared when going to the next
part: it doesn’t
exist or could not be read.
E92
Step bending-too many steps
The programmed step-bend cannot have so many steps. Try
reprogramming it, and eventually the whole part.
E93
Beam drive error
There is an error on one of the drives controlling the beam. Check
them and resolve the problem. They must be ready to run.
E94
F_CycStopAxe failure, please
make a “Tracer”
Should not happen. If it does, call a technician to make a trace and
have him send it to
E95
Combined machine IO
configuration
(Option K1 - combined machine)
–
configuration of the outputs/
inputs is not correct when option K1 is activated.
E97
Negative face length
Flange length is too short for the radius programmed.
E98
Incorrect face
This message means that the face number programmed in the bend
sequence is outside the limits. This message can normally not
happen on a part programmed on the CybTouch but could on an
imported part. Reprogram the part entirely.
E99
Illegal stop
This message means that there is a problem between the stop
number and the face number programmed in the bend sequence.
One or the other is outside the limits. This message can normally
not happen on a part programmed on the CybTouch but could on an
imported part. Reprogram the part entirely.
E100
Stop does not suit
No gauging solution was found for the current bend. This bend
cannot be made with the actual machine configuration.
E101
Station error
(Option K1 - combined machine)
–
this message is displayed when
trying to go in auto mode, and no station is defined. Or if one of the
switches defining the current station changes state while working.
E102
Cycle station Time out
(Option K1 - combined machine)
–
the duration of the station
change cycle exceeded the maximum allowed. Check if the station
movement is not impeded in any way.
E103
Clamping opened
The machine cannot start if the tools are not properly clamped.
Check the status of the tools on page
E104
Station locked
(Option K1 - combined machine)
–
it is not possible to work on the
station, because the tooling is still locked (input Unlocked not
active). Check the locking device of the station.
E105
Cylinder not in position
(Option K1 - combined machine)
–
the station cannot change
position, because one of the cylinder’s status is unknown, i.e. it is
neither closed nor opened. Correct the situation from the page
Содержание CybTouch 12PS
Страница 1: ...CybTouch Series User Manual JANUARY 2020 V5 0 for Synchronized Press Brakes ...
Страница 6: ...User Manual CybTouch series CybTouch Series User Manual JAN 2020 V5 0 5 63 ...
Страница 10: ...User Manual CybTouch series CybTouch Series User Manual JAN 2020 V5 0 9 63 SCREEN MAP ...
Страница 11: ...User Manual CybTouch series CybTouch series User Manual JAN 2020 V5 0 10 98 SCREEN MAP CONTINUED ...