E02
Pump motor off
The pump motor needs to be on for the sequence to start.
E03
Buffer Full
The part-program memory is full, you cannot add another
sequence.
E04
Code refused
The level code to access the selected page is not correct. Try again
or ask for it if you do not have it.
E05
File not compatible
The loaded part-program is incompatible with the NC. This part
should be deleted.
E06
Machine parameter file
problem
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
E07
Machine parameters not
compatible, please format data
This message appears when a software update has been made over
a much older version and the parameters are no longer compatible.
It can also appear if the uploaded parameters (with RFlink) are
much older or newer than the current software version and they are
not be compatible. A new start-up of the machine must be made.
Contact your dealer.
E08
Lismisc File not compatible
Information message, which will disappear when restarting the NC.
E09
Save program problem
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
E10
File not found [ ]
A file is missing, and the code indicates which one. Call Cybelec with
this code to know which file is missing.
E11
Write to file problem
This file is corrupt and cannot be saved. Try to restart the NC. If the
problem persists, format the memory.
E12
X under minimum limit
Operator entered a value under the limit, or a memorized value in
the program is under the limit. The wrong value flashes and must be
corrected.
E13
X over maximum limit
Operator entered a value over the limit, or a memorized value in
the program is over the limit. The wrong value flashes and must be
corrected.
E14
Fw SetVar Error [ ]
May occur when a feature is configured, but the dedicated input/
output is not configured. Usually this is solved by loading the default
input/output configuration (see the machine parameters).
E15
Bottoming not allowed
This message is displayed when a bottoming sequence is
programmed, and bottoming is not allowed with either one of the
tools.
E16
Fw Axes Error [ ] ...
Axis manager error. The number gives more information. Most
common errors are described in messages E55 to E68.
If other error numbers are listed, please send conditions of
problem, traces and parameters to the Cybelec Technical support
for assistance.
E17
Programming error
Machine parameters incorrectly configured; the error page is
displayed.
E18
No Backgauge defined
All the back gauges programmed in Machine Parameters have none
selected for mode. Select at least one mode other than none.
E19
Quantity = 0
When pressing start, the programmed amount of parts to be made
is ‘0’. See Number of parts
for more information.
E20
Cycle repeat = 0
Cannot start cycle because repeat cycle function is set to “0”.
E
RROR
M
ESSAGES
Содержание CybTouch 12PS
Страница 1: ...CybTouch Series User Manual JANUARY 2020 V5 0 for Synchronized Press Brakes ...
Страница 6: ...User Manual CybTouch series CybTouch Series User Manual JAN 2020 V5 0 5 63 ...
Страница 10: ...User Manual CybTouch series CybTouch Series User Manual JAN 2020 V5 0 9 63 SCREEN MAP ...
Страница 11: ...User Manual CybTouch series CybTouch series User Manual JAN 2020 V5 0 10 98 SCREEN MAP CONTINUED ...