CXR DS-8124 Скачать руководство пользователя страница 1

 

 

 

 

 
 

ADSL2+ IP DSLAM 

DS-8124 

Release 1.2   

 

Installation Guide 

 

 
 

 

Aug. 2007 Release 1.2 

Copyright © 2006 CXR Anderson Jacobson. All Rights Reserved. 
 
This document contains information that is the property of CXR. This document may not 

be copied, reproduced, reduced to any electronic medium or machine readable form, or 
otherwise duplicated, and the information herein may not be used, disseminated or 

otherwise disclosed, except with the prior written consent of CXR AJ. 
 

CXR ANDERSON JACOBSON 
Sales, Research    & Development, Manufacturing
 : 

Rue de l'Ornette - 28410 Abondant FRANCE 
Tel: +33 237.62.88.00 – Fax:  +33 237.62.88.01 
WEB Site:

 http://www.cxr.anderson-jacobson.com

Support: 

[email protected]

 

Tel: +33 237.62.88.04 

 

Part Number : 

8000 602 338

 Indice:

 02

   

Version .1.2

Содержание DS-8124

Страница 1: ...ic medium or machine readable form or otherwise duplicated and the information herein may not be used disseminated or otherwise disclosed except with the prior written consent of CXR AJ CXR ANDERSON J...

Страница 2: ...21 INSTALLING AN SFP TRANSCEIVER 22 CONNECTING TO THE 1000BASE TAND 10 100BASE TX INTERFACE 23 CONNECTING RJ 21 CABLES 24 CONNECTING RJ 21 CABLES 24 CONSOLE MANAGEMENT 26 5 TROUBLESHOOTING 33 TROUBLES...

Страница 3: ...be used disseminated or otherwise disclosed except with the prior written consent of CXR Every effort has been made to ensure the accuracy of this document However due to ongoing improvements and rev...

Страница 4: ...m the C O side to the Customer Premises Equipment CPE ADSL is a form of xDSL service that delivers an asymmetric data rate over a twisted copper pair ADSL delivers a higher rate downstream towards the...

Страница 5: ...her layer protocol policy control o STP RSTP IEEE 802 1 d w o IGMP Snooping v2 o DHCP relay and relay agent option 82 TR 101 o Radius client and IEEE802 1x port authentication o PPPoE Circuit ID taggi...

Страница 6: ...ice for different users such as Hotels SOHOs residential users and enterprises The end user can use DSL for Various applications such as Telecommuting Video streaming On line game IPTV Distance learni...

Страница 7: ...type at optical interface port 2 The connector is RJ 45 at copper interface port 3 When plug in SFP the work interface will select optical interface automatic and copper interface is assistant interf...

Страница 8: ...and Tag based 3 Multicasting IGMP snooping 250 groups Dynamic Static Configuration 4 QoS IEEE802 1p based COS 4 priority output queue per port RFC 2475 DiffServ TOS 5 DHCP DHCP relay and relay agent o...

Страница 9: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 8 Remote software upgrade 9 Remote file backup and restore 9...

Страница 10: ...all the necessary tools and cabling before installing the switch and splitter Note that these devices can be installed on any suitably large flat surface or in a standard EIA 19 inch rack Package Cont...

Страница 11: ...properly grounded power outlet is within 2 5 m 8 ft of the access switch The access switch should be located in a cool dry place with at least 10 cm 4 in of space on the sides for ventilation Place t...

Страница 12: ...ng the switch be sure you install any optional modules If you have purchased an optional slide in 1000BASE T SFP 1000BASE X install it now and following the instructions below To rack mount devices 1...

Страница 13: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 DS 8124c Figure 4 1 Attaching the Brackets 4 Mount the device in the rack using four rack mounting screws 13...

Страница 14: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 DS 8124 14...

Страница 15: ...ling the Switch in a Rack 3 If installing a single switch only turn to Powering On the Switch at the end of this chapter 4 If installing several devices we recommend using one stack for the switch and...

Страница 16: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 Desktop or Shelf Mounting 1 Attach the four adhesive feet to the bottom of the first switch DS 8124 DS 8124c 16...

Страница 17: ...an AC power source making sure there are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Powering On the Switch at the end of this chapter 4 I...

Страница 18: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 Wall mount Mounting 1 Attach the four adhesive feet to the bottom of the first switch DS 8124 18...

Страница 19: ...on Guide Oct 2006 Release 1 2 DS 8124c Figure 4 4 Installing the Switch on a Wall 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of space on all s...

Страница 20: ...Release 1 2 3 If installing a single switch only go to Powering On the Switch at the end of this chapter 4 If installing multiple switches attach four adhesive feet to each one Place each device squa...

Страница 21: ...8124 if noise is present in the Electrical ground this noise can leak to the ADSL circuit through the Surge protectors and interfere with the proper operation of ADSL links both AC DC power supplies...

Страница 22: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 Installing an SFP Transceiver DS 8124 DS 8124c 22...

Страница 23: ...switch before installing or removing a transceiver However you should always first disconnect the network cable before removing a transceiver Connecting to the 1000BASE T and 10 100BASE TX Interface...

Страница 24: ...a cable with an RJ 21 on one end and free wiring on the other end will be required Figure 4 6 Connecting to the Punch down Blocks Follow the steps below to connect an EE Splitter to a building s phone...

Страница 25: ...DS 8124 DS 8124c Installation Guide Oct 2006 Release 1 2 25...

Страница 26: ...oader startup If you not press any key in the below state system will load the default startup sequence to do boot our system U Boot 1 1 3 Jun 29 2006 16 38 55 BAS ver 1 00 07 U Boot code 00200000 002...

Страница 27: ...and old ramdisk 2 Startup from new kernel and old ramdisk 3 Startup from old kernel and new ramdisk 4 Startup from new kernel and new ramdisk 5 Startup from NFS 6 Startup from RAM 7 U boot command li...

Страница 28: ...2 loading update newkernel image to 0x3000000 JFFS2 load complete 1081262 bytes loaded to 0x3000000 JFFS2 loading update newramdisk image to 0x5000000 In this state system will take two three minutes...

Страница 29: ...ixp0 ip addr 192 168 0 210 mac addr 00 05 ca 00 42 11 gateway 0 0 0 0 net mask 255 255 255 0 eth0 ip addr 172 168 1 210 mac addr 00 05 ca 00 42 15 gateway 0 0 0 0 net mask 255 255 255 0 After configur...

Страница 30: ...s to enter the sys group and then type help or to show the information about the sys User can also type help argument to display that how to execute this argument BAS sys help help Display command lis...

Страница 31: ...ts arguments BAS sys help info Show general system information info show switchname location contact phone show Display general system information switchname Set the switch name location Set the locat...

Страница 32: ...006 Release 1 2 BAS end BAS comand line program ended Above description we only tell user the method about group sys and the methods of other groups like the same way And we can type help to show the...

Страница 33: ...r ADSL Switch Ports may be defective Verify that the Access Switch and attached CPE are powered on Be sure the RJ 21 cables are plugged into the Access Switch from ADSL2 modem through the Phone line p...

Страница 34: ...Group 2 System alarm The system alarms are triggered by ALARM OUT or kernel oops Alarm Type Alarm Level Alarm Group Alarm Description DoorOpen Major sys Device has been opend PowerFail Major Sys Powe...

Страница 35: ...lable Seconds 15M LOSS Major GEMINAX 15 minutes threshold error Loss of Signal Seconds 15M LOFS Major GEMINAX 15 minutes threshold error Loss of Frame Seconds 15M LOLS Major GEMINAX 15 minutes thresho...

Страница 36: ...r GEMINAX 15 minutes threshold error Coding Violations 1D FEC Major GEMINAX 1 Day threshold error Forward Error Corrections 1D CV Major GEMINAX 1 Day threshold error Coding Violations 15M HEC Major GE...

Страница 37: ...s 1D USERCELL1D Major GEMINAX 1 Day threshold error User cells 1D IBE Major GEMINAX 1 Day threshold error Cell Bit Error 1D CRC_P Major GEMINAX 1 Day threshold error non pre emptive packets with CRC e...

Страница 38: ...re might be red and the other red with white stripes Also an RJ 45 connector must be attached to both ends of the cable With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and p...

Страница 39: ...s are used for both transmit and receive Use 100 ohm Category 5 5e or better unshielded twisted pair UTP or shielded twisted pair STP cable for 1000BASE T connections Also be sure that the length of a...

Страница 40: ...net ports The following table shows the pin assignments Pins Circuit Pins Circuit Pins Circuit Pins Circuit 1 26 Port 1 7 32 Port 7 13 38 Port 13 19 44 Port 19 2 27 Port 2 8 33 Port 8 14 39 Port 14 20...

Страница 41: ...nments EIA Circuit CCITT Signal Description Switch s DB 9 DTE Pin PC DB 9 DTE Pin BB 104 RxD Received Data 2 2 BA 103 TxD Transmitted Data 3 3 AB 102 SGND Signal Ground 5 5 Console Port to 9 Pin DTE P...

Страница 42: ...124 DS 8124c Management guide Aug 2006 release 1 1 DS 8124 DS 8124c Management guide Sept 2006 release 1 2 DS 8124 DS 8124c Management guide Oct 2006 release 1 3 DS 8124 DS 8124c Management guide Apr...

Страница 43: ...ccessories for DS 8124 DS 8124c 1 A Bracket Mounting Kit It contains two brackets and four screws for attaching the brackets to the DSLAM 2 One Power Cord 3 Four adhesive foot pads 4 One CD containing...

Страница 44: ...FP interface w o optical module for uplink port Remark 1000 Base SX 1000 Base LX 1000 Base LHX and 1000 Base ZX Ethernet interface comply with IEEE802 3ab Gigabit Ethernet IEEE802 3z Gigabit Ethernet...

Страница 45: ...gent option 82 Rate Limitation from 64K to Maximum rate the step is 64K Interworking RFC2684 MPoA LLC VCMUX VPN pass through RFC2516 PPPoE packet forwarding Trouble Shooting LED indicator for power va...

Страница 46: ...ailable for network signals Also synonymous with wire speed the actual speed of the data transmission along the cable Collision A condition in which packets transmitted over the cable interferes with...

Страница 47: ...Ethernet IEEE 802 3u Defines CSMA CD access method and physical layer specifications for 100BASE TX Fast Ethernet IEEE 802 3x Defines Ethernet frame start stop requests and timers used for flow contr...

Страница 48: ...DSL signals from POTS signals to prevent mutual interference Switched Ports Ports that are on separate collision domains or LAN segments Transmission Control Protocol Internet Protocol TCP IP Protoco...

Отзывы: