Anti-static handling guidelines
Make sure that electrostatic handling precautions are taken immediately before handling PCBs and other
static sensitive components.
Before handling any static-sensitive items, operators should get rid of any electrostatic charge by
touching a sound safety earth. Always handle PCBs by their sides and avoid touching any components.
4.1
Unpacking the ViAC-RTK
Remove the equipment from its packing, and check the contents against the following list:
•
ViAC-1ZC- 1 zone controller.
•
ViAC-CPP- Ceiling Pull Cord.
•
ViAC-ODP- Overdoor Indicator Plate.
•
ViAC-CNP- Cancel Plate.
•
Accessible WC Sticker.
•
Instruction Sticker (to be located within the WC).
•
Installation and operation manual.
•
Accessory pack with the following contents:-
o
8 number device 2 part terminals.
o
8 no device mounting screws.
Installation
4.2
Connecting the ViAC-RTK Assist Call remote kit
The ViAC-1ZC controller mounts onto a 25mm UK double gang back box ,
the ViAC-CCP, ViAC-ODP and
ViAC-CNP device plates mount onto a 25mm UK single gang back box.
The devices are wired to the terminals marked Line 0 and +, the devices are polarity sensitive, cabling
between the controller and the devices is 2 core 1 mm CSA flex, wired in a radial circuit.
All system wiring should be installed to meet the appropriate parts of BS 7671 (Wiring Regulations).
Other national standards of installation should be adhered to where applicable.
Extra Low Voltage (ELV) Wiring:- Always segregate low voltage wiring from the main wiring