Curtiss GEM-120A Скачать руководство пользователя страница 7

- 7 -

BREW CONE, UNIVERSAL 7.38"D.
KIT, RETROFIT TIMER GEM120A 120V
KIT, LIQUID LEVEL CONTROL
SPRAYHEAD, RED (.131 DIA) 
KIT, PROBE, ASSY WATER LEVEL W/HEX FITTING, O-RING & NUT 
LABEL, SWITCH PANEL GEM120A CURTIS (NEWER UNITS)
LABEL, SW PANEL GEM-120A CURTIS (OLDER UNITS)
KIT,ELEMENT, HEATING 1.6KW120V W/JAM NUT & SILICONE WASHERS
KIT, ELEMENT, HEATING 2KW 220V W/ JAM NUT & SILICONE WASHERS
POWER CORD, 6' 14/3 BLK SJTO
VALVE, INLET 1 GPM 120V 10W ALP/AP/TLP YELLOW BODY
THERMOSTAT, CAPILLARY SPST 250V 25A GEM
KIT, VALVE REPAIR FOR WC-866, WC-889, WC-816, WC-817, WC-818
VALVE, DELTROL DUMP RIGHT 120V.
FAUCET, HOT WATER W/JAM NUT
LIGHT, BREW 115V GREEN
LIGHT, BREW 220V 
SWITCH, ROCKER 120V RED 
SWITCH, ROCKER BREW 120V GREEN 
KIT,SPRAYHEAD FITTING PLASTIC
TUBE, 5/16" I.D. SILICONE GEN USE 
THERMOSTAT, MANUAL RESET 120/240 VAC 25A 220 DEG F MAX
THERMOSTAT, HI LIMIT HEATER CONTROL DPST 277V 40A
ELEMENT, WARMER ASSY 100W 120V WITH SILICONE BOOTS
SWITCH, TOGGLE SPST 25A 125/250 VAC RESISTIVE 
LEG, SCREW BUMPER 3/8-16 STD 
BREW CONE,ASSY W/SPLASH POCKET NON-METAL DELUXE (OPTIONAL)
COVER, FRONT GEM-120A/120P/230A/200R/300IL/600ILD
COVER, TOP ALPGT/D500GT/D60GT TLP/TCTS/CBS/GEMSS
PLUG, TANK DRAIN ULTEM 1000F
KIT, VALVE REPAIR USE ON WC-826/WC-826L/WC-847
WASHER, .35 GPM .5" USE ON WC-825
LID ASSEMBLY, TANK 
TANK, COMPLETE GEM-120A 120V
TANK, COMPLETE GEM-120A 120/220V DV
LABEL, BOTTOM GEM-120A

  1
  2

  3
  4

  5

  6

  6A

  7

  7A

  8
  9

10
11
12
13
14
14A
15
16
17
18
19
19A
20
21
22
23
24
25
26
27
28
29
30
30A
31

WC-3621-101
WC- 603-101K-GEM
WC-608-101K
WC-2936
WC-5502-01
WC-3920-01
WC-3920T
WC-  904-04
WC-  906-04
WC-1200
WC-  826L
WC- 504
WC-3763
WC-  817
WC-1809
WC-  207
WC-  203
WC-  114R
WC-  122
WC-2977-101K
WC-5310
WC- 523
WC- 522
WC-  970
WC-  102
WC-3503
WC-3338-101
WC-5452
WC-58117
WC-43058
WC-3765L
WC-  829
WC-37008
WC-5466
WC-54133
WC-3920B

PAPER  FILTERS

Part Number

Description

CR- 12
CR- 10

FILTER FOR BREW CONE WC-3338-101 (500/PKG)
FILTER FOR BREW CONE WC-3621-101 (1000/PKG) 

GEMINI 120A   Parts List

ITEM №

PART №

DESCRIPTION

Содержание GEM-120A

Страница 1: ...ur Curtis Company Service Technician DO NOT immerse the unit in water or any other liquid To reduce the risk of fire or electric shock DO NOT open service panels There are no user serviceable parts inside Keep hands and other items away from hot areas of the unit during operation Never clean with scouring powders or harsh chemicals INSTALLATION This Curtis unit is pre set and ready to go from the ...

Страница 2: ...s prepare a mild solution of detergent and warm water CAUTION Do not use cleansers bleach liquids powders or any other substance containing chlorine These products promote corrosion and will pit the stainless steel USE OF THESE PRODUCTS WILL VOID THE WARRANTY DAILY CLEANING 1 Wipe exterior surfaces with a damp cloth removing spills and debris 2 Slide the brewcone out and clean it Wipe the sprayhea...

Страница 3: ...t cup Replace if the seat cup damaged 3 Clean the coffee level gauge glass a Remove the gauge glass cap unscrewing it from the top of the shield b Carefully pull out the gauge glass Brush out the inside of the glass with a detergent solution Rinse the sight glass tube of all detergent residue c Inspect the gasket seals at the top and bottom of the gauge glass Clean these gaskets d Assemble the gau...

Страница 4: ...ned out 3 Grounded probe 4 Defective or burned out water level control board PROBLEM WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW POSSIBLE CAUSE SOLUTION 8 Thermostat is off Check the thermostat to make sure it is in the ON position Turn the thermostat stem clockwise until it stops 9 Burned out heating element Check element for continuity and or check with clamp ammeter This should ...

Страница 5: ...d 110 to 120 volts across terminals 8 and 9 of the timer The RED wire on terminal 8 supplies power to open the dump valve If no voltage is present replace the timer If the timer works when the brew switch is pressed then check the dump valve using a voltmeter on the terminals If it shows 110 to 120 volts but no water flows through the valve clean out the valve or replace the coil 11 Water level is...

Страница 6: ... 6 GEMINI 120A Parts List 8 27 28 B 25 6 3 16 14 21 1 4 20 24 5 7 13 9 10 11 12 2 15 15 18 17 23 26 29 30 31 19 21 22 ...

Страница 7: ...SY 100W 120V WITH SILICONE BOOTS SWITCH TOGGLE SPST 25A 125 250 VAC RESISTIVE LEG SCREW BUMPER 3 8 16 STD BREW CONE ASSY W SPLASH POCKET NON METAL DELUXE OPTIONAL COVER FRONT GEM 120A 120P 230A 200R 300IL 600ILD COVER TOP ALPGT D500GT D60GT TLP TCTS CBS GEMSS PLUG TANK DRAIN ULTEM 1000F KIT VALVE REPAIR USE ON WC 826 WC 826L WC 847 WASHER 35 GPM 5 USE ON WC 825 LID ASSEMBLY TANK TANK COMPLETE GEM ...

Страница 8: ...ORD 6 18 3 BLK SWITCH ROCKER 120V RED SATELLITE SERVER 1 GAL LID SATELLITE PLASTIC GEM3 GAUGE GLASS ASSEMBLY 8 C SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH BRACKET GAUGE GLASS FORMED SHANK FAUCET D T CHROME FAUCET S NONLOCKING FAUCET ESP BLACK NONLOCKING OPTIONAL KIT FAUCET S SERIES SATELLITE STAND LEG SCREW BUMPER 3 8 16 STD KIT WARMER ELEMENT 100W 120VAC ILLUSTRATED PARTS LIST GEM 3 5 8 11 13 ...

Страница 9: ... 9 ELECTRICAL DIAGRAM GEM120A 10 ...

Страница 10: ... 10 ELECTRICAL DIAGRAM GEM120A 63 ...

Страница 11: ... 11 ELECTRICAL DIAGRAM GEM 5 8 ROUGH IN DRAWING GEM 120A ROUGH IN DRAWING GEM 3 GEM 5 ...

Страница 12: ...es 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsib...

Отзывы: