Curtiss GEM-120A Скачать руководство пользователя страница 4

- 4 -

POSSIBLE CAUSE

SOLUTION

TROUBLE SHOOTING

Open the water line and make sure water flows to the brewer.

Turn off brewer. Disconnect wires from water inlet coil terminals and 

connect a power cord to the terminals. Plug cord into a 110v outlet 

and verify that water flow when plugged in and stops when cord 

is disconnected. If valve does not respond to this test, replace the 

valve.

When water in the heating tank is below the probe tip, yet water is 

not refilling, pull the wire off the probe terminal. If water starts flow-

ing into the tank, find ground, clean or replace the probe.

Pull the wire from the probe terminal. With a volt meter, check the 

voltage at the water inlet coil terminals. This should read 110 to 

115 volts. If no voltage is present, check the water level control 

board. Make sure that the back of the board is grounded securely 

to the mounting bracket. Check for loose wire connections. Replace 

board.

1.  Water line turned off or  

  filter clogged up.

2.  Water inlet valve coil  

  burned out.

3.  Grounded probe.

4.  Defective or burned out  

  water level control board.

PROBLEM: 

WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW

POSSIBLE CAUSE

SOLUTION

8. Thermostat is off.

Check the thermostat to make sure it is in the ON position. Turn the 

thermostat stem clockwise until it stops.

9. Burned out heating  

 

 element.

Check element for continuity and/or check with clamp ammeter. This 

should show a reading of approximately 15 amps. If no power is go-

ing through element, replace it.

PROBLEM: 

WATER DOES NOT FLOW INTO HEATING TANK

POSSIBLE CAUSE

SOLUTION

Turn power off and observe the water level in the heating tank. If 

water continues to flow in, clean or replace the valve.

Pull wire off from probe terminal. Touch the water tank shell with 

the terminal at the end of this wire. If water stops flowing, clean or 

replace the probe.

If probe is okay, check the water level control board. The water level 

control board must be securely grounded. Check for loose connec-

tions. Check for voltage at the inlet valve terminals. Replace board.

5.  Defective water inlet  

 valve.

6. Probe limed up.

7.  Loose or ungrounded  

  water level control board.

PROBLEM: 

WATER IN HEATING TANK OVERFLOWING

GEMINI 120A

Содержание GEM-120A

Страница 1: ...ur Curtis Company Service Technician DO NOT immerse the unit in water or any other liquid To reduce the risk of fire or electric shock DO NOT open service panels There are no user serviceable parts inside Keep hands and other items away from hot areas of the unit during operation Never clean with scouring powders or harsh chemicals INSTALLATION This Curtis unit is pre set and ready to go from the ...

Страница 2: ...s prepare a mild solution of detergent and warm water CAUTION Do not use cleansers bleach liquids powders or any other substance containing chlorine These products promote corrosion and will pit the stainless steel USE OF THESE PRODUCTS WILL VOID THE WARRANTY DAILY CLEANING 1 Wipe exterior surfaces with a damp cloth removing spills and debris 2 Slide the brewcone out and clean it Wipe the sprayhea...

Страница 3: ...t cup Replace if the seat cup damaged 3 Clean the coffee level gauge glass a Remove the gauge glass cap unscrewing it from the top of the shield b Carefully pull out the gauge glass Brush out the inside of the glass with a detergent solution Rinse the sight glass tube of all detergent residue c Inspect the gasket seals at the top and bottom of the gauge glass Clean these gaskets d Assemble the gau...

Страница 4: ...ned out 3 Grounded probe 4 Defective or burned out water level control board PROBLEM WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW POSSIBLE CAUSE SOLUTION 8 Thermostat is off Check the thermostat to make sure it is in the ON position Turn the thermostat stem clockwise until it stops 9 Burned out heating element Check element for continuity and or check with clamp ammeter This should ...

Страница 5: ...d 110 to 120 volts across terminals 8 and 9 of the timer The RED wire on terminal 8 supplies power to open the dump valve If no voltage is present replace the timer If the timer works when the brew switch is pressed then check the dump valve using a voltmeter on the terminals If it shows 110 to 120 volts but no water flows through the valve clean out the valve or replace the coil 11 Water level is...

Страница 6: ... 6 GEMINI 120A Parts List 8 27 28 B 25 6 3 16 14 21 1 4 20 24 5 7 13 9 10 11 12 2 15 15 18 17 23 26 29 30 31 19 21 22 ...

Страница 7: ...SY 100W 120V WITH SILICONE BOOTS SWITCH TOGGLE SPST 25A 125 250 VAC RESISTIVE LEG SCREW BUMPER 3 8 16 STD BREW CONE ASSY W SPLASH POCKET NON METAL DELUXE OPTIONAL COVER FRONT GEM 120A 120P 230A 200R 300IL 600ILD COVER TOP ALPGT D500GT D60GT TLP TCTS CBS GEMSS PLUG TANK DRAIN ULTEM 1000F KIT VALVE REPAIR USE ON WC 826 WC 826L WC 847 WASHER 35 GPM 5 USE ON WC 825 LID ASSEMBLY TANK TANK COMPLETE GEM ...

Страница 8: ...ORD 6 18 3 BLK SWITCH ROCKER 120V RED SATELLITE SERVER 1 GAL LID SATELLITE PLASTIC GEM3 GAUGE GLASS ASSEMBLY 8 C SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH BRACKET GAUGE GLASS FORMED SHANK FAUCET D T CHROME FAUCET S NONLOCKING FAUCET ESP BLACK NONLOCKING OPTIONAL KIT FAUCET S SERIES SATELLITE STAND LEG SCREW BUMPER 3 8 16 STD KIT WARMER ELEMENT 100W 120VAC ILLUSTRATED PARTS LIST GEM 3 5 8 11 13 ...

Страница 9: ... 9 ELECTRICAL DIAGRAM GEM120A 10 ...

Страница 10: ... 10 ELECTRICAL DIAGRAM GEM120A 63 ...

Страница 11: ... 11 ELECTRICAL DIAGRAM GEM 5 8 ROUGH IN DRAWING GEM 120A ROUGH IN DRAWING GEM 3 GEM 5 ...

Страница 12: ...es 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsib...

Отзывы: