background image

TABLE 3

RS-422 inputs  

PARAMETER

MIN.

TYP.

MAX.

UNITS

CONDITION/DETAILS

Inputs

2

Signaling rate

DATA

10

Mbps

DCLK

10

MHz

Input voltage

operating range

 

-7

12

V

Do not exceed operating range.

logic 0

0.2

V

V

IN+

 - V

IN-

.

logic 1

0.2

V

V

IN+

 - V

IN-

.

common mode voltage

-7

12

V

overvoltage protection

-7

12

V

Voltages outside of this range can damage input.

ESD protection

-8

8

kV

Human Body Model.

Input resistance

between inputs

120

Ω

Module powered on and inputs terminated.

between inputs

120

Ω

Module powered off and inputs terminated.

each input to GND

20

Module powered on.

each input to GND

60

Module powered off.

TABLE 4

RS-422 outputs 

PARAMETER

MIN.

TYP.

MAX.

UNITS

CONDITION/DETAILS

Outputs

1

Signaling rate

PROG_DCLK

1

MHz

Output voltage

absolute operating range

-0.3

6

V

Absolute voltage of the operating signal must stay within this 
range.

logic 0

-2

V

V

0+

 - V

0- ; 

R

LOAD

 = 100Ω.

logic 1

2

V

V

0+

 - V

0- ; 

R

LOAD

 = 100Ω.

common mode voltage

-7

12

V

short circuit current

150

mA

short circuit duration

s

Only one output may be shorted at a time.

ESD protection

-15

15

kV

Human Body Model.

Output resistance

120

Ω

SAM/DEC/008

3

19 Apr. 2016 | DST/Z/010

CURTISSWRIGHTDS.COM 

Содержание SAM/DEC/008

Страница 1: ...PCM streams and provides a high speed programming link for Acra KAM 500 systems The unit uses a single USB 2 0 connection in the ground station programming PC The PCM decommutator accepts either differential ended RS 422 inputs or single ended TTL inputs With BIØ L codes only a single input is used For other line codes an additional data clock DCLK line is required Any sync word up to 32 bits can ...

Страница 2: ...Slots 1 USB 2 0 compatible Can be connected to any USB 2 0 port Mass 155 g 5 47 oz Design metric is grams Power consumption 5V 500 mA From USB port total power 2 5 W Environmental ratings See Environmental Qualification Handbook operating temperature 0 60 C Chassis base side plate temperature storage temperature 20 70 C TABLE 2 BTTL inputs PARAMETER MIN TYP MAX UNITS CONDITION DETAILS Inputs 2 Sig...

Страница 3: ...uts 120 Ω Module powered off and inputs terminated each input to GND 20 MΩ Module powered on each input to GND 60 kΩ Module powered off TABLE 4 RS 422 outputs PARAMETER MIN TYP MAX UNITS CONDITION DETAILS Outputs 1 Signaling rate PROG_DCLK 1 MHz Output voltage absolute operating range 0 3 6 V Absolute voltage of the operating signal must stay within this range logic 0 2 V V0 V0 RLOAD 100Ω logic 1 ...

Страница 4: ...del Output voltage operating range 7 12 V logic 0 2 V V0 V0 RLOAD 100Ω logic 1 2 V V0 V0 RLOAD 100Ω common mode voltage 7 12 V short circuit current 250 mA short circuit duration s Only one output may be shorted at a time Input resistance between inputs 120 Ω Module powered on and inputs terminated between inputs 120 Ω Module powered off and inputs terminated each input to GND 20 MΩ Module powered...

Страница 5: ... signals do not float with respect to the SAM DEC 008 For details on grounding see TEC NOT 063 Grounding and shielding of the Acra KAM 500 NOTE Even though the SAM DEC 008 supports 10 Mbps in NRL L RNZL 15 the decommutation software and or the PC specifications may degrade this performance Drivers installation The SAM DEC 008 is detected by the operating system as a LAN9500 USB to Ethernet control...

Страница 6: ...AN9500A adapter has a static IP address 1 Go to Control Panel Network and Internet Network and Sharing Center 2 Click Change adapter settings 3 Right click Local Area Connection LAN9500A USB2 0 to Ethernet and then click Properties 4 In the Local Area Connection 8 Status dialog click Properties ...

Страница 7: ...Internet Protocol Version 4 TCP IPv4 and then click Properties 6 Click the Use the following IP address radio button and then type the IP address you want For example if you use the IP address shown above then the IP address of the SAM DEC 008 will be 192 168 29 201 ...

Страница 8: ...ISSWRIGHTDS COM 2016 Curtiss Wright All rights reserved Specifications are subject to change without notice All trademarks are the property of their respective owners 7 Click OK 8 Select Client for Microsoft Networks and then click Configure ...

Страница 9: ...llow the SAM DEC 008 to send and receive data Status LEDs The SAM DEC 008 has two status LEDs a USB link LED and a PCM decom LED Refer to the following table for LED descriptions LED RED BLUE YELLOW GREEN PURPLE USB link Reset System programming Reserved ARP IP address configured and ready for use SAM DEC 008 configuration being loaded PCM decom No PCM lock1 1 The SAM DEC 008 is a minor frame deco...

Страница 10: ...eam differential ended alternative to pin 1 4 DATA RS 422 inputs PCM data stream terminated by 120Ω resistor 5 DNC Do not connect 6 X PROG RS 485 Programming data terminated by 120Ω resistor 7 DNC Do not connect 8 X PROG RS 485 Programming data terminated by 120Ω resistor 9 DNC Do not connect 10 DNC Do not connect 11 DNC Do not connect 12 DCLK RS 422 inputs PCM bit clock differential ended alterna...

Страница 11: ...REVISION DIFFERENCES STATUS SAM DEC 008 First release Recommended for new programs Supporting software SOFTWARE DETAILS DAS Studio 3 User interface for setup and management of data acquisition network switches recorders and ground stations in an integrated environment KSM 500 This module is supported by the KSM 500 suite of software tools SWP SDK 004 Software Development Kit for SAM DEC 008 Relate...

Страница 12: ...pr 2016 DST Z 010 CURTISSWRIGHTDS COM This page is intentionally blank 2016 Curtiss Wright All rights reserved Specifications are subject to change without notice All trademarks are the property of their respective owners ...

Отзывы: