Curtiss-Wright | PG Drives Technology
SK77981-14
43 | R-net Technical Manual | Chapter 2 - Installation
CAUTION:
When the control system is first switched on after a connection, or system component change the Timer will be displayed
whilst the system checks itself and then the Re-start icon will be displayed. Switch the control system off and on again to
operate.
Route and secure the cable in such a way as to prevent damage, for example by crushing or cutting.
5.1
CHARGER CONNECTOR
An Off-Board Charger can be connected to the Joystick Module’s charger connector. The charger connector is Neutrik 3 pin
type NC3FPP or equivalent, and the maximum charging current is 12A rms. Only chargers fitted with Neutrik NC3MX plugs
should be connected into the Joystick Module. The pin connections of the chargi ng socket are as below.
Pin
Connection
1
Battery Positive
2
Battery Negative
3
Inhibit
NOTE:
The maximum permissible charging current is 12Arms.
6
POWER MODULE & ISM WIRING
6.1
GENERAL
Study the data sheets for the Power Module and the ISM to identify:
The output current, ratings and restrictions.
The connector pin assignments.
Recommendations for the cross -sectional area, ratings and materials for wiring are given in the table in section 6.2. These
depend on the application. You are responsible for establishing the suitability of the particular wiring arrangement used on the
wheelchair. Curtiss-Wright can make general recommendations for wiring to R-net control systems, but Curtiss-Wright accepts
no responsibility for the wiring arrangement used.
Make sure that the connectors you use are reliable under all operating conditions and correctly wired with no short circuits. Do
not use unsuitable components - it may result in poor wheelchair reliability.
WARNING:
The chair manufacturer is responsible for establishing the suitability of the particular wiring arrangements used on the
wheelchair, for both normal use and stalled conditions. Curtiss-Wright can make general recommendations for wiring for R-
net control systems, but Curtiss-Wright accepts no responsibility for, and accepts no liability for losses of any kind arising
from, the actual wiring arrangement used.
Содержание R-NET
Страница 1: ...PG DRIVES TECHNOLOGY R NET TECHNICAL MANUAL SK77981 14 ...
Страница 46: ...Curtiss Wright PG Drives Technology SK77981 14 46 R net Technical Manual Chapter 2 Installation 6 1 3 CRIMPING ...
Страница 58: ...Curtiss Wright PG Drives Technology SK77981 14 58 R net Technical Manual Chapter 2 Installation ...
Страница 174: ...Curtiss Wright PG Drives Technology SK77981 14 174 R net Technical Manual Chapter 8 ISM 8 ...
Страница 194: ...SK77981 14 194 R net Technical Manual Chapter 10 Diagnostics Curtiss Wright PG Drives Technology ...
Страница 206: ...SK77981 14 206 R net Technical Manual Chapter 12 Specifications Curtiss Wright PG Drives Technology ...