SK77981-14
180 | R-net Technical Manual | Chapter 10 – Diagnostics
Curtiss-Wright | PG Drives Technology
2.1.1 IDENTIFIED MODULE
This identifies which module of the control system has registered the problem, such:
PM
Power Module
JSM
Joystick Module
ISM
Intelligent Seating/lighting Module
2.1.2 TRIP TEXT
The Trip Text gives a brief description of the trip type.
2.1.3 TRIP CODE
The 4 digit code displayed gives the exact trip that has been recorded.
2.1.4 EXAMPLE
The example screen shown in section 2.1 shows the following information
Identified Module
Power Module
Trip Text
Low Battery
Trip Code
2C00
This means the battery needs charging or there is a bad connection to the battery.
Check the connections to the battery. If the connections are good, try charging the battery.
2.2
SYSTEM LOG SCREEN
All trips are stored in the system log, whether they have been resolved or are still active. The system log stores the Trip Text and
the number of occurrences. The trips are stored in their respective Modules within the system. The system log can be accessed
using OBP, a Diagnostic Test Tool or the R-net PC Programmer.
Entering the System Log using OBP.
Select System from the menu.
Select Diagnostics from the menu.
This displays the Diagnostic screen that shows the connected modules and the version history. See diagram
below.
Содержание R-NET
Страница 1: ...PG DRIVES TECHNOLOGY R NET TECHNICAL MANUAL SK77981 14 ...
Страница 46: ...Curtiss Wright PG Drives Technology SK77981 14 46 R net Technical Manual Chapter 2 Installation 6 1 3 CRIMPING ...
Страница 58: ...Curtiss Wright PG Drives Technology SK77981 14 58 R net Technical Manual Chapter 2 Installation ...
Страница 174: ...Curtiss Wright PG Drives Technology SK77981 14 174 R net Technical Manual Chapter 8 ISM 8 ...
Страница 194: ...SK77981 14 194 R net Technical Manual Chapter 10 Diagnostics Curtiss Wright PG Drives Technology ...
Страница 206: ...SK77981 14 206 R net Technical Manual Chapter 12 Specifications Curtiss Wright PG Drives Technology ...