159 | R-net Technical Manual | Chapter 8 – ISM-8
4
CONNECTIONS
4.1
R-NET REBUS
WARNING:
The Bus connections can only be used to connect the ISM-8 to an R-net Control System using Curtiss-Wright supplied R-net
Communication Cables. Curtiss-Wright accept no liability for any losses of any kind if an incorrect cable is used.
4.2
INHIBITS
The ISM-8 contains Inhibit 18 to 33 connections. These connections can be used to limit speed, inhibit drive and /or inhibit
actuator channels. Refer to Section 5 – Programming for full details.
Signals to the Inhibit connector can be passive, i.e. A resistor varying from 0
Ω
to 10k
Ω
, or active, i.e. a voltage source varying
from 0V to 3.3V.