User Manual
– DuraNET 3300
Connector Descriptions
MNL-0676-01 Rev A4
ECO- N/A
Effective: 26 Feb 21
Page 35 of 84
Production Configuration:
Figure 3.2: Production Front View
Table 3.2: Production Connector Identification & Partnumbers
Recept
-acle
Used
For
Recept
-acle
Label
#
# of
Pins
Wire
Gauge
(AWG)
Panel Connector
Part Number
Mating Cable Connector
Part Number
Power
J1
2
12
Glenair 801-033-07M10-2PA
Glenair 801-008-16M10-2SA
Copper
I/O
J2
85
22-28
Glenair
801-033-07M17-85SA
Glenair
801-008-16M17-85PA
Copper
I/O
J3
130
22-28
Glenair
801-033-07M21-130SA
Glenair
801-008-16M21-130PA
Optical
I/O
J4
4
N/A
Glenair
180-118-ZR08-11-4S1 shell
181-043-126C termini
Glenair
180-118-ZR06-11-4P1 shell
181-043-126C termini
Connector Pinouts
This section provides the pinouts necessary for creating cables to connect to this assembly. If custom
cabling is not designed and built by Curtiss-Wright, all EMI and EMC consideration must be handled by
the customer.
Note: EAU and Production cable pinouts are identical other than the power connector.