Warmer Does Not Heat
NOTE
5IFTBUFMMJUFIFBUJOHFMFNFOUJTEFTJHOFEUPLFFQCSFXFEDPGGFFIPUCVUJTOPUPGTVGmDJFOUXBUUBHFUP
SFIFBUDPMEDPGGFF
5VSOPOQPXFSUPUIFXBSNFS$IFDLGPSQPXFSBUUIFUFSNJOBMTPGUIFXBSNFSFMFNFOU*GQPXFSJTTVQQMJFEUP
UIFFMFNFOUUFSNJOBMTCVUUIFFMFNFOUEPFTOPUIFBUSFQMBDFUIFFMFNFOU
2
*GUIFXBSNFSJTOPUSFDFJWJOHQPXFSDIFDLUIFXJSJOHUPUIFFMFNFOUBOEUIFXBSNFSTXJUDI
Setting the Brew Timer
3FNPWFUIFUPQDPWFS.BLFTVSFUIBUUIFXBUFSTVQQMZUPUIFCSFXFSJTPOBOEUIBUQPXFSJTDPOOFDUFE5VSO
UIFUPHHMFTXJUDIPOUIFCBDLPGUIFCSFXFSUPUIF0/QPTJUJPO
2
8BJUGPSUIF#3&88)&/-*5MJHIUUPDPNFPO
3
5VSOUIF#3&84&-&$503TXJUDIUPQPTJUJPO
4
1MBDFBOFNQUZTBUFMMJUFPOUIFCSFXEFDLXJUIUIFMJEPGG*OTFSUBOFNQUZCSFXCBTLFUJOUPUIFCSFXSBJMT
5
1VMMVQUIFDBSECPBSEDPWFSPOUIFDPOUSPMCPBSEBOEMPDBUFUIFSFEQSPHSBNNJOHCVUUPO TFFEJBHSBNT
CFMPX
6
1VTIBOEIPMEUIF SFEQSPHSBNNJOHCVUUPOVOUJMUIFQSPHSBNNJOH-&%nBTIFT
7
1SFTTUIF#3&8TXJUDIPOUIFGSPOUQBOFM
8IFOUIFTBUFMMJUFJTIBMGGVMMQSFTTUIF#3&8TXJUDIBHBJO)BMGCBUDIJTOPXQSPHSBNNFE
&NQUZUIFTBUFMMJUFBOEUVSOUIF#3&84&-&$503TXJUDIUPQPTJUJPO
3FQFBUTUFQTUISPVHIXIFOUIF#3&88)&/-*5MJHIUUPDPNFTCBDLPOUIJTUJNFXBJUJOHGPSUIFTBUFMMJUF
UPmMMDPNQMFUFMZEVSJOHQSPHSBNNJOH
(&."#3&8&35306#-&4)005*/((6*%&
ø
%
TROUBLESHOOTING GUIDE
TG16
INLET
VALV
E
LEVEL
HALF_SW
CO
MMON
NO
NC
BRE
W
_SW
PROBE
Control board
Front
panel
Programming
button (red)
Programming
LED